Viking VWH2410 Installation Manual Download Page 3

BASIC SPECIFICATIONS - INTERIOR AND EXTERIOR POWER HOODS

RECOM.

NUMBER OF  250 WATT

120VAC/60Hz

DESCRIPTION

CFM

1

HALOGEN     HEAT LAMPS FILTERS

SPACERS

MAX. AMPS

3

LIGHTS         (bulb sold

(Int.-Interior; Ext.-Exterior)

separately)

(Interior/Exterior)

24”W.   

300 int./600 int./900 ext./1200 ext.

2

1

2

1

5.0/6.2/8.7/6.1

30” W.

300 int./600 int./1200 int./900 ext./1200 ext

2

1

2

1

5.0/6.2/8.7/8.7/6.1

36”W.* 

300 int./

600 int./1200 int./900 ext./1200 ext.

2

1

2

2

5.0/6.2/8.7/8.7/6.1

42”W.*

600 int./1200 int./900 ext./1200 ext.

2

1

2

2

6.2/8.7/8.7/6.1

48”W., 54”W.* 1200 int./1200 ext./1500 ext.

3

2

3

2

11.1/8.4/9.1

60”W.* 

1200 int./1200 ext./1500 ext.

4

2

4

1

11.5/8.8/9.5

66”W.*

1200 int./1200 ext./1500 ext.

4

2

4

2

11.5/8.8/9.5

*1200 CFM interior or exterior or 1500 CFM exterior (if applicable) ventilator should be used with all outdoor approved models

and when indoor models are installed over ranges/rangetops with gas grill.

RECOM.

NUMBER OF

120VAC/60Hz

DESCRIPTION CFM

1

HALOGEN

FILTERS

SPACERS

MAX. AMPS

3

LIGHTS

(Int.-Interior; Ext.-Exterior)

(Interior/Exterior)

36”W.*

600 int./1200 int./900 ext./1200 ext.

4

4

2

4.9/7.4/7.4/4.7

42”W.*

600 int./1200 int.
900 ext./1200 ext./1500 ext.

4

4

4

4.9/7.4/4.8/5.4

54”W.*

1200 int./1200 ext./1500 ext.

6

6

4

8.2/5.6/6.2

66”W.*

1200 int./1200 ext./1500 ext.

8

8

4

9.0/6.3/7.1

18” H. Indoor Wall Hoods

RECOM.

NUMBER OF 

120VAC/60Hz

DESCRIPTION

CFM

1

HALOGEN     FILTERS        SPACERS

MAX. AMPS

3

LIGHTS

(Int.-Interior; Ext.-Exterior)

(Interior/Exterior)

36”W.

1200 int./1200 ext./1500 ext.

2

2

2

8.7/6.1/6.8

48”W.

1200 int./1200 ext./1500 ext.

3

3

2

11.5/8.8/9.5

60”W. 

1200 int./1200 ext./1500 ext.

4

4

1

11.5/8.8/9.5

18” H. Outdoor Wall Hoods*

18” H. Indoor Island Hoods

RECOMMENDED

MAX. DUCT

MODEL NUMBER

CFM

1

DUCT SIZE

RUN

(ft.)

For Use with hoods:

VIV300 (interior)

300

7” round

50

VIV600 (interior)

600

7” round

50

VIV1200 (interior)

1200

10” round

50

VEV900 (exterior)

900

10” round

50

VEV1200 (exterior)

1200

10” round

50

VEV1500 (exterior)

1500

10” round

75

PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY
VENTILATION PRODUCT
1.  •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly overstated.
2.  •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained

installer.

•Straight runs and gradual turns are best; for example, each 90

o

elbow is equivalent to 5-10 feet (1.52 - 3.05 m) of straight run.

•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.  
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.

3.  •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with

ground. 

3

Summary of Contents for VWH2410

Page 1: ...Viking Installation Guide Built In 18 H Hoods Indoor and Outdoor Models...

Page 2: ...e National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 3 When cutting or drilling into wall...

Page 3: ...CFM1 HALOGEN FILTERS SPACERS MAX AMPS3 LIGHTS Int Interior Ext Exterior Interior Exterior 36 W 1200 int 1200 ext 1500 ext 2 2 2 8 7 6 1 6 8 48 W 1200 int 1200 ext 1500 ext 3 3 2 11 5 8 8 9 5 60 W 1200...

Page 4: ...72 167 6 cm 182 9 cm 66 72 167 6 cm 182 9 cm HEIGHT OF OUTDOOR HOOD The bottom of the hood should be 30 76 2 cm to 36 91 4 cm above the grill surface The hood should be installed 4 1 2 11 4 cm plus t...

Page 5: ...er cable from service panel to installation location See Basic Specifications on page 13 for the maximum amp requirements Top Mounting Holes Wood Strip provided locally 11 2 x3 4 Slot for Wood Strip R...

Page 6: ...be mounted as shown below Custom Hood Canopy 1 Position ventilator system inside of the custom hood canopy and center it front to back and left to right 2 Bottom mounting holes fasten ventilator syst...

Page 7: ...n to plate before attaching plate to hood 3 Remove wire box cover Remove a knockout from the wiring box Feed 6 of power cable through opening and attach cable to wiring in wiring box with appropriate...

Page 8: ...r Kit 300 or 600 CFM also see instructions supplied with ventilator kit 1 Make sure barrel nuts and wing nut are engaged halfway onto threaded stud 2 Lift ventilator into canopy may be easier to turn...

Page 9: ...of power cable through the openings and attach cables to wiring box with appropriate connectors 4 Wire black to black white to white and green or bare wire beneath green ground screw Replace wiring bo...

Page 10: ...e upper two thirds of the shingles around the cutout area Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 c...

Page 11: ...cm diameter hole making sure that the 11 4 3 2 cm diameter electrical wiring hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided It is recommended tha...

Page 12: ...nd the top and sides of the cutout area only Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 cm diameter ho...

Page 13: ...hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided All six holes in the back panel must be filled or any moisture that may get inside the housing cou...

Page 14: ...151 2 39 4 cm 281 4 71 8 cm VEV900 EXTERIOR BLOWER LINE IN 120 VAC 60 HZ 15 AMP MAX WIRING BOX GREEN BLACK WHITE BLACK BLACK BLACK WHITE GREEN WHITE WHITE GREEN VEV1200 VEV1500 22 1 8 56 2 cm B 10 1 8...

Page 15: ...3 8 cm 9 1 8 23 2 cm 9 5 8 24 4 cm FOR 900 or 1200 CFM EXTERIOR VENTILATOR INSTALLATION 24 30 36 42 W Models FOR 300 or 600 CFM INTERIOR VENTILATOR INSTALLATION 24 30 36 42 W Models 4 5 8 11 7 cm B 5...

Page 16: ...15 16 76 0 cm 66 W Models 65 7 8 167 3 cm 32 15 16 83 7 cm FOR 1200 or 1500 CFM EXTERIOR VENTILATOR INSTALLATION 48 54 60 66 W Models FOR 1200 CFM INTERIOR VENTILATOR INSTALLATION 30 36 42 48 54 60 66...

Page 17: ...T IN CUSTOM VENTILATOR SYSTEM DIMENSIONS VBCV Models 900 or 1200 CFM EXTERIOR VENTILATOR INSTALLATION 30 36 42 W Models 300 or 600 CFM INTERIOR VENTILATOR INSTALLATION 30 36 42 W Models D 8 1 4 20 9 c...

Page 18: ...0 W Models 58 1 4 148 0 cm 29 1 8 74 0 cm 66 W Models 64 1 4 163 2 cm 32 1 8 81 6 cm D 8 1 4 20 9 cm 6 15 2 cm 5 1 2 14 0 cm 3 7 6 cm 2 1 2 6 4 cm Cutout for 10 25 4 cm duct D 9 3 8 23 8 cm 9 1 2 24 4...

Page 19: ...cm C D 36 W Models 35 7 8 91 1 cm 17 15 16 45 56 cm 42 W Models 41 7 8 106 4 cm 20 15 16 18 18 cm 54 W Models 53 7 8 136 8 cm 26 15 16 68 42 cm 66 W Models 65 7 8 167 3 cm 32 15 16 83 66 cm D C FOR 12...

Page 20: ...RNAL POWER INTERNAL POWER 120 V 120 V 5 8 1 6 cm 5 8 1 6 cm B B 9 3 8 23 8 cm 9 5 8 24 4 cm 1 3 16 3 0 cm A A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm 18 3 4 47 6 cm 9 1 8 23 2 cm 5...

Page 21: ...A B 54 W Model 52 1 4 132 7 cm 26 1 8 66 4 cm 66 W Model 64 1 4 163 2 cm 32 1 8 81 6 cm 5 8 1 6 cm B A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm Cutout for 10 25 4 cm duct 9 1 2 24...

Page 22: ...1R PS042707J Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange...

Reviews: