BASIC SPECIFICATIONS - INTERIOR AND EXTERIOR POWER HOODS
RECOM.
NUMBER OF 250 WATT
120VAC/60Hz
DESCRIPTION
CFM
1
HALOGEN HEAT LAMPS FILTERS
SPACERS
MAX. AMPS
3
LIGHTS (bulb sold
(Int.-Interior; Ext.-Exterior)
separately)
(Interior/Exterior)
24”W.
300 int./600 int./900 ext./1200 ext.
2
1
2
1
5.0/6.2/8.7/6.1
30” W.
300 int./600 int./1200 int./900 ext./1200 ext
2
1
2
1
5.0/6.2/8.7/8.7/6.1
36”W.*
300 int./
600 int./1200 int./900 ext./1200 ext.
2
1
2
2
5.0/6.2/8.7/8.7/6.1
42”W.*
600 int./1200 int./900 ext./1200 ext.
2
1
2
2
6.2/8.7/8.7/6.1
48”W., 54”W.* 1200 int./1200 ext./1500 ext.
3
2
3
2
11.1/8.4/9.1
60”W.*
1200 int./1200 ext./1500 ext.
4
2
4
1
11.5/8.8/9.5
66”W.*
1200 int./1200 ext./1500 ext.
4
2
4
2
11.5/8.8/9.5
*1200 CFM interior or exterior or 1500 CFM exterior (if applicable) ventilator should be used with all outdoor approved models
and when indoor models are installed over ranges/rangetops with gas grill.
RECOM.
NUMBER OF
120VAC/60Hz
DESCRIPTION CFM
1
HALOGEN
FILTERS
SPACERS
MAX. AMPS
3
LIGHTS
(Int.-Interior; Ext.-Exterior)
(Interior/Exterior)
36”W.*
600 int./1200 int./900 ext./1200 ext.
4
4
2
4.9/7.4/7.4/4.7
42”W.*
600 int./1200 int.
900 ext./1200 ext./1500 ext.
4
4
4
4.9/7.4/4.8/5.4
54”W.*
1200 int./1200 ext./1500 ext.
6
6
4
8.2/5.6/6.2
66”W.*
1200 int./1200 ext./1500 ext.
8
8
4
9.0/6.3/7.1
18” H. Indoor Wall Hoods
RECOM.
NUMBER OF
120VAC/60Hz
DESCRIPTION
CFM
1
HALOGEN FILTERS SPACERS
MAX. AMPS
3
LIGHTS
(Int.-Interior; Ext.-Exterior)
(Interior/Exterior)
36”W.
1200 int./1200 ext./1500 ext.
2
2
2
8.7/6.1/6.8
48”W.
1200 int./1200 ext./1500 ext.
3
3
2
11.5/8.8/9.5
60”W.
1200 int./1200 ext./1500 ext.
4
4
1
11.5/8.8/9.5
18” H. Outdoor Wall Hoods*
18” H. Indoor Island Hoods
RECOMMENDED
MAX. DUCT
MODEL NUMBER
CFM
1
DUCT SIZE
RUN
2
(ft.)
For Use with hoods:
VIV300 (interior)
300
7” round
50
VIV600 (interior)
600
7” round
50
VIV1200 (interior)
1200
10” round
50
VEV900 (exterior)
900
10” round
50
VEV1200 (exterior)
1200
10” round
50
VEV1500 (exterior)
1500
10” round
75
PROPER INSTALLATION/DUCTING IS EXTREMELY IMPORTANT TO ENSURE MAXIMUM PERFORMANCE FROM ANY
VENTILATION PRODUCT
1. •All CFMs stated are based on tests at .1 static pressure: without applying static pressure, CFM would be greatly overstated.
2. •Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained
installer.
•Straight runs and gradual turns are best; for example, each 90
o
elbow is equivalent to 5-10 feet (1.52 - 3.05 m) of straight run.
•Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirement, if any.
3. •Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with
ground.
3