Viking VMOS200AL Service Manual Download Page 30

30

REV 1 (Apr 2011)

3.  Secure  latch  head  (with  two  (2)  mounting  screws)  to 

oven flange.

4.  Make  sure  that  the  monitor  switch  is  operating 

properly 

and check continuity of the monitor circuit.  Refer  to chapter  

"Test Procedure" and Adjustment procedure.

DOOR SENSING SWITCH/PRIMARY SWITCH/SECONDARY SWITCH AND MONITOR SWITCH ADJUSTMENT

1.  Disconnect  the  power  supply  cord,  and  then  remove 

outer case.

2.  Open the door and block it open.
3.  Discharge high voltage capacitor.
If the door sensing switch, primary switch, secondary switch 
and monitor switch do not operate properly due to a misad-
justment, the following adjustment should be made.
4.  Loosen the two (2) screws holding latch head to the oven 

cavity front flange.

5.  With door closed, adjust latch head by moving it back 

and

  forth,  and  up  and  down.  In  and  out  play  of  the  door 

allowed  by  the  upper  and  lower  position  of  the  latch 
head should be less than 0.5mm. The vertical position 
of the latch head should be adjusted so that the door 
sensing switch, primary switch and secondary switch are  
activated with the door closed. The horizontal position of 
the latch head should be adjusted so that the plunger of 
the monitor switch is pressed with the door closed.

6.  Secure the screws with washers firmly.
7.  Check the operation of all switches. If each switch has 

not  activated  with  the  door  closed,  loosen  screw  and 
adjust the latch head position.

After adjustment, check the following. 

1.  In and out play of door remains less than 0.5mm when 

in the latched position. First check upper position of latch 
head, pushing and pulling upper portion of door toward 
the oven face. Then check lower portion of the latch 

Figure C-3. Latch Switch Adjustments

  head, pushing and pulling upper portion of door toward 

the oven face. Both results (play in the door) should be 
less than 0.5mm.

2.  The door sensing switch, primary switch and secondary 

switch  interrupt  the  circuit  before  the  door  can  be 
opened.

3.  Monitor switch contacts close when door is opened.
4.  Re-install outer case and check for microwave leakage 

around door with an approved microwave survey meter. 
(Refer to Microwave Measurement Procedure.) 

DOOR/LATCH HEAD/SPRING REPLACEMENT

REMOVAL

1.  Disconnect the power supply cord.
2.  Push the open button and open the door.
3.  Remove choke cover by inserting a putty knife (thickness 

of about 0.5mm) into the gap between the choke cover 
and door frame as shown in 

Figure C-4

 to free engaging 

parts.

4.  Release two (2) pins of door panel from two (2) holes of 

upper and lower oven hinges by lifting up 

Figure C-5

.

LATCH HEAD/SPRING REMOVAL

5.  Lay  door  on  protected  surface,  then  slide  latch  head 

forward until it clears the center holes that hold the latch  
head.  

6.  Unhook spring from latch head and door frame.
7.  The latch head and spring is now free.

RE-INSTALL

1.  Hook one end of the latch spring to latch head, then hook 

the other end of the spring to door frame spring catch.*

2.  With latch spring attached at both ends, extend latch 

head forward until it can be inserted into the center holes 
that hold the latch head.

3.  Check for smooth movement.
4.  Catch two (2) pins of door panel on two (2) hole of upper 

and lower oven hinges and insert choke cover Figure 
C-5.

*NOTE:

 

Latch head and spring can be installed without removing

the door panel, but if you cannot, remove the six screws 

holding the door panel to the frame and remove door panel.

Door Sensing 
Switch

Monitor Switch

Switch Lever

Secondary 
Switch

Latch Heads

Door

Primary 
Switch

Figure C-4. Door/Latch head Replacement

Choke Cover

Door Frame

Putty Knife

Summary of Contents for VMOS200AL

Page 1: ...O EXCESSIVE MICROWAVE ENERGY 2 BEFORE SERVICING 2 WARNING TO SERVICE PERSONNEL 4 MICROWAVE MEASUREMENT PROCEDURE 5 FOREWORD AND WARNING 7 PRODUCT SPECIFICATIONS 8 GENERAL INFORMATION 8 OPERATION 10 TR...

Page 2: ...on check as per the Microwave Measure ment Procedure outlined in this service manual If microwave emissions level is in excess of the specified limit contact Viking Service immediately 1 888 845 4641...

Page 3: ...3 REV 1 Apr 2011 Notes...

Page 4: ...ge capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedu...

Page 5: ...ately 4 Set the cooking control on Full Power Cooking Mode Close the door and select a cook cycle of several minutes If the water begins to boil before the survey is completed replace it with 275 ml o...

Page 6: ...en cavity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 3 1 2 in and made of an electrically nonconductive material such as glass or plastic T...

Page 7: ...be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing Service person nel Do not con...

Page 8: ...HHS Rules CFR Title 21 Chapter 1 Subchapter J and Canadian Standards Association Health CANADA SPECIFICATION GENERAL INFORMATION GROUNDING INSTRUCTIONS This oven is equipped with a three prong groundi...

Page 9: ...ed over accidentally CAUTION DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE ROUND GROUNDING PRONG FROM OVEN DIAGRAM 1 One touch door open button Push to open door 2 Door latches The oven will not op...

Page 10: ...d secondary interlock relay are activated with the following results The circuits to the turntable motor the cooling fan motor and the high voltage components are de energized the oven lamp remains on...

Page 11: ...h one of the SENSOR pads NOTE The oven should not be operated on sensor immediately after plugging in the unit Wait two minutes before cooking on SENSOR 2 Thecoilofshut offrelay RY 1 isenergized thetu...

Page 12: ...WITCH H N NOIS E FILTE R UNIT N O COM DOOR S E NS ING S WITCH NOIS E S UP P R E S S ION C OIL LINE C R OS S C AP AC IT OR 0 22uF AC 250V 0 0033uF AC 125V 0 0033uF AC 125V LINE B Y P AS S C AP AC IT O...

Page 13: ...ts CAUTION BEFORE REPLACING A BLOWN monitor FUSE TESTMONITORSWITCHANDPRIMA RY SWITCH FOR PROPER OPERATION RE FER TO CHAPTER TEST PROCEDURE NOTE monitor FUSE AND MONITOR SWITCH ARE REPLACED AS AN ASSEM...

Page 14: ...Whenever troubleshooting is performed with the power supply cord disconnected It may in some cases be necessary to connect the power supply cord after the outer case has been removed in this event 1...

Page 15: ...operly when STOP CLEAR key is touched Buzzer should sound and or time of day should appear in display Oven lamp does not light when door is opened Oven lamp does not go out when door is closed Oven la...

Page 16: ...BE OBSERVED Power output of the magnetron can be measured by performing a water temperature rise test This test should only be used if above tests do not indicate a faulty magnetron and there is no d...

Page 17: ...of the oven cavity especially the cooling fan and air guide 5 Reconnect all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the...

Page 18: ...ce the secondary interlock switch 5 Reconnect all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8...

Page 19: ...ol panel assembly is divided into two units Con trol Unit and Key Unit and also the Control Unit is divided into two units LSI Unit and Power Unit and troubleshooting by unit replacement is described...

Page 20: ...key produces no signal 2 3 Other possible problems caused by defective control unit a Buzzer does not sound or continues to sound b Clock does not operate properly c Cooking is not possible When testi...

Page 21: ...he relay RY1 on the control unit with an A C voltmeter The meter should indicate 120 volts if not check oven circuit RY1 and RY2 Relay Test These relays are operated by D C voltage Check voltage at th...

Page 22: ...in 1000 milliliters measuring cup 3 Place the container on the center of tray in the oven cavity 4 Close the door 5 Touch the Timer Clock pad once the Power Level pad twice the Start pad once and the...

Page 23: ...fter approximately 25 seconds push plunger of select switch for more than 3 seconds This condition is same as judgement by AH sensor 9 4 After approximately 3 seconds the display shows xx xx which is...

Page 24: ...POINT INDICATION OF OHM METER Between N and H Open Circuit Between terminal N and GRY Short Circuit Between terminal H and RED Short Circuit If incorrect readings are obtained replace the noise filte...

Page 25: ...nge the resistance values in parallel with R107 R111 of IC2 Changing the resistance value results in that there is the same potential at both F 3 terminal of the absolute humiditysensorandAN0terminalo...

Page 26: ...WIRING 1 Disconnect the power supply cord 2 Make sure that a definite click can be heard when the microwave oven door is unlatched Hold the door in a closed position with one hand then push the door o...

Page 27: ...rt one of the power transformer from the high voltage capacitor 7 Remove one 1 screw holding capacitor holder with the high voltage rectifier to the base plate 8 Disconnect rectifier terminal from cap...

Page 28: ...he Keysheet ribbon from the Power board lift the Control Unit off 4 ProceedinreverseordertoreassemblewithnewControl Unit 2 Removeturntableandturntablesupportfromovencavity 3 Laytheovenonit sbackside R...

Page 29: ...es smooth after installation Make sure that the axis of the shaft is not slanted 5 Install the fan motor to the the oven cavity back plate with the two 2 screws 6 Connect the wire leads to the fan mot...

Page 30: ...itch Adjustments head pushing and pulling upper portion of door toward the oven face Both results play in the door should be less than 0 5mm 2 The door sensing switch primary switch and secondary swit...

Page 31: ...1 0mm 3 Door is positioned with its face pressed toward cavity face plate 4 Check for microwave leakage around door with an approved microwave survey meter Refer to Microwave Measurement Procedure No...

Page 32: ...wire must be connected to the terminal with N mark on the power supply cord BLK WHT H N NOTE The grounding conductor of the power supply cord has been grounded by power supply cord fixing screw The sc...

Page 33: ...ntrol panel frame with key unit VMOS200AL 1 3 2 FPNLCB543MRK0B Control panel frame with key unit VMOS200WH 1 3 2 FPNLCB616MRK0A Control panel frame with key unit VMOS200PL 1 3 2 FPNLCB545MRK0B Control...

Page 34: ...0 Door assembly VMOS200GM 1 5 1 CDORFB510MRK0 Door assembly VMOS200SA 1 5 1 CDORFB450MRK0 Door assembly VMOS200EP 1 5 1 CDORFB447MRK0 Door assembly VMOS200FG 1 5 2 LSTPPB021MRF0A Latch head 1 AE 5 3 M...

Page 35: ...3 2 1 7 1 1 11 4 10 7 2 7 2 1 12 1 9 7 3 7 6 7 6 1 8 7 4 7 4 4 2 7 4 1 10 7 9 4 4 7 1 4 1 1 1 1 2 2 2 2 2 2 2 2 2 7 5 7 5 7 5 6 5 4 5 1 13 7 5 7 7 7 5 7 5 7 5 7 7 4 3 1 7 1 7 1 6 1 7 7 1 6 12 6 6 7 1...

Page 36: ...11 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H DOOR PARTS MISCELLANEOUS CONTROL PANEL PARTS 5 1 5 3 5 2 5 4 Actual wire harness may be different from illustration 6 8 6 2 3 4 3 2 3 3 3 5 3...

Page 37: ...AND ACCESSORIES Non replaceable items DOOR PROTECTION SHEET PLASTIC BAG PACKING CASE TOP PAD ASSEMBLY INTO THE OVEN CAVITY 6 4 TURNTABLE TRAY 6 3 TURNTABLE SUPPORT 6 7 VIKING CD BOTTOM PAD ASSEMBLY TR...

Page 38: ...38 REV 1 Apr 2011 NOTES...

Page 39: ...39 REV 1 Apr 2011 NOTES...

Page 40: ...eval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher COPYRIGHT 2011 BY VIKING ALL RIGHTS R...

Reviews: