Viking VK277 Instruction Manual Download Page 2

ESCUTCHEON MATERIALS

1. Adjustable Standard Dry Escutcheon:

Brass UNS-C26000 or UNS-C26800

2. Recessed Dry Escutcheon: Cold

Rolled Steel UNS-G10080

AVAILABLE FINISHES

Recessed: Chrome-Enloy

®

(patents

pending) or White Polyester

Standard Adjustable: Chrome-Enloy

®

or White Polyester sprinkler with a
Chrome-Enloy

®

Sleeve and Escutch-

eon

Plain

Barrel:

Chrome-Enloy

®

or

Brass (sprinkler only)

ACCESSORIES

Standard Dry Sprinkler Wrench Part No.

07297W/B

Recessed Dry Sprinkler Wrench: Part

No. 07565W/B***

***Requires a separate ½" ratchet (not available

from Viking).

Replacement Escutcheons:
1. Adjustable Standard Dry Escutcheon:

Base Part No. 08086F

2. Recessed Dry Escutcheon: Base Part

No. 05459A

5. ORDERING INFORMATION

For proper shipment, specify: model, fin-
ish, temperature rating, escutcheon
type, and length ("A" Dimension). Viking
Quick Response Dry Horizontal Side-
wall Sprinklers are ordered in specific
lengths noted as the "A" Dimension (see
Figures 1 through 4). The A Dimension
is the distance from the face of the fitting
(tee) to the finished surface of the wall in
which it is to be installed. The Viking
Quick Response Dry Horizontal Side-
wall Sprinkler must be ordered and man-
ufactured specifically for one of three
styles of installation: with the adjustable
recessed escutcheon (see Figure 1),
with the adjustable standard escutcheon
(see Figures 2 and 3), or the plain barrel
(see Figure 4). For limits of adjustment
for the recessed escutcheon, see Figure
1. Details and limits of adjustment for the
standard escutcheon style, with 2" (50,8

TECHNICAL DATA

Sprinkler 106 m

September 16, 2005

Approval Chart

Quick Response Ordinary Hazard

Dry Horizontal Sidewall Sprinklers

Thread Size

Sprinkler Description

Nominal K-factor

4

Order Length Increment

3

Listings

2

NPT

BSP

Sprinkler Style

Base Part No.

1

SIN

Inches

mm

cULus

5

NYC

1"

Adjustable Standard

13169

VK277

8.0 U.S. (11,5 metric)

for lengths up to 20".

For lengths exceeding

20", refer to Figure 5

on page 106 o.

½"

12,7

A1

25 mm

13175

VK277

½"

12,7

A1

1"

Adjustable Recessed

13171

VK279

¼"

6,35

B2

25 mm

13177

VK279

¼"

6,35

B2

1"

Plain Barrel

13170

VK275

½"

12,7

A3

25 mm

13176

VK275

½"

12,7

A3

Approved Temperature Ratings

A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C),

and 286 °F (141 °C)

B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C)

Available Approved Finishes

1 - Chrome-Enloy

®

or White Polyester sprinkler with a Chrome-Enloy

®

Sleeve and Es-

cutcheon with "A" dimensions 1-1/2" to 45-1/2" (38,1 mm to 1 156 mm)

2 - Chrome-Enloy

®

or White with "A" dimensions 3-1/4" to 47-1/2" (82,5 mm to 1 207 mm)

3 - Chrome-Enloy

®

or Brass with "A" dimensions 3" to 47" (76,2 mm to 1 194 mm)

Footnotes

1

Base part number is shown. For complete part number, refer to Viking's current price schedule.

2

This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer

for any additional approvals.

3

Minimum

length (A Dimension) is 1-1/2" (38,1 mm) for sprinkler VK277, 3" (76,2 mm) for sprinkler VK275, and 3-1/4” (82,5 mm) for sprinkler

VK279.

Maximum

standard (listed) length is 45-1/2" (1 156 mm) for sprinkler VK277, 47" (1 194 mm) for sprinkler VK275, and 47-1/2" (1 207

mm) for sprinkler VK279.

4

Metric K-Factors shown are for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-Factor shown

by 10.0.

5

Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada for light and ordinary hazard occupancies.

NOTE:

Viking Quick Response Ordinary Hazard Dry HSW Sprinklers must be positioned between 4" and 12" (102 mm and 305 mm) below

smooth, flat, horizontal ceilings, and not less than 4" (102 mm) from walls other than the wall in which they are installed. Keep the leading edge
of the deflector and the centerline axis of the sprinkler frame oriented parallel with the ceiling. Refer to appropriate Installation Guide.

Temperature

KEY

Finish

A1X

Escutcheon (if applicable)

5/16" (7,9 mm) outward adjustment

Ceiling

4" (102 mm) minimum

12" (305 mm) maximum

Wall

5/8" (16 mm)

1-7/8" (47,6 mm) minimum

2-1/2" (63,5 mm) maxi-

Available

Adjustment

3-1/16"

(77,8 mm)

5/16" (7,9 mm) inward adjustment

For "A" Dimension:

1. Determine the distance from face of tee to

face of finished wall.

2. Round to nearest ¼" (6,35 mm) between

3-1/4" and 47-1/2" (82,5 mm and 1 207 mm).

NOTE:

The sprinkler will be recessed approxi-

mately 5/16" (7,9 mm) with 5/8" (15,8 mm)
horizontal adjustment available.

Figure 1

Adjustable Recessed QR Ordinary Hazard Dry Horizontal Sidewall Sprinkler VK279

Minimum wall opening size:

2-1/8" (54 mm) diameter.

Maximum wall opening size:

2-1/2" (63,5 mm) diameter.

QUICK RESPONSE

ORDINARY HAZARD

DRY HORIZONTAL SIDEWALL

SPRINKLERS

(VK277, VK279, VK275)

OBSOLETE

Reviews: