Viking VIL900 Instructions Download Page 3

CONNECT WIRING TO VIL900 INLINE FAN

1.   The opposite end of this wiring will be connected to the 

rough-in plate in the next step.

2.  Remove wiring box cover from the inline fan.
3.   Attach  an  appropriate  UL  approved  cable  connector  to 

the wiring hole in the wiring box.

4.   Bring electrical wiring through the cable connector in the 

electrical box.

5.  Make electrical connections per the diagram shown below

6.  Attach wiring box cover.

CONNECT WIRING TO THE ROUGH-IN PLATE

1.   Run 115VAC electrical power cable from the service panel 

and from the inline fan to the rough-in plate part number 
PV300008.

2.   Remove appropriate knockouts from the range hood rough 

in box.

3.   Attach appropriate UL approved cable connectors to the 

wiring holes in the range hood rough-in box.

4.   Feed 6” of power cable through the cable connectors in 

the rough-in plate.

5.   Using the diagram below make all electrical connections 

to the rough-in plate.  

6.  Attach wiring box cover to rough-in  plate.

7.   Attach  rough-in  plate  to  the  studs  at  the  inside  top  of 

the  range  hood  with  the  (4)  #10-24  nuts  part  number 
PV300146 provided.

8.   Connect the plugin power cables of the rough-in  kit to 

the range hood.

3

�����

�����

�����

�����

���������

��������

���������

���������

������

�������

��

����

������������

115V

Reviews: