Viking VGBQ1302 Installation Manual Download Page 14

3/8” 

3/8” 
male 

male 
flare 

flare 
adapter

adapter

3/8” 
male 
flare 
adapter

Type 1, 
QCC-1
connector

3/8” female 

flare adapter

3/8” male 
flare adapter

Regulator 

Assembly

NOTE:

 

Tank must be 

mounted in vertical position
for proper Ventilation

LP/Propane Tank Connection

Outdoor grills orificed for use with LP/Propane
gas come equipped with a high capacity
hose/regulator assembly for connection to a
standard 20 lb. LP/Propane cylinder equipped
with a Type 1, QCC-1 connector. Hose assembly
must comply with Elastomeric Composite Hose
and Couplings for conducting Propane and
Natural Gas, CAN/CGA-8.1 standard or the
Theromplastic Hose and Hose Couplings for 
conducting Propane and Natural Gas 

CAN1-8.3 standard. 
(See LP/Propane tank
requirements below). Each
tank is supplied with a dust
cap. Place dust cap on
cylinder valve outlet
whenever the cylinder is not in
use. Only install the type of dust
cap on the cylinder valve outlet that is
provided with the cylinder valve. Other
types of caps or plugs may result in leakage of
propane. 

Connect the regulator to the grill unit by
screwing the 3/8” flare coupling to the 3/8” flare
adapter. Connect to the tank valve by screwing
the Type 1, QCC-connector to the LP/Propane
tank. Open the tank valve and check the

connection between the regulator and the 
Type 1, QCC-1 fitting for leaks with a soapy water
solution. If bubbles appear, tighten the
connection. Repeat until all leaks have been
stopped. ALWAYS CHECK FOR LEAKS AFTER
EVERY LP/PROPANE TANK CHANGE. Any joint
sealant used must be an approved type and be
resistive to the actions of LP/Propane gas.

27

LP/Propane Tank Requirements

A dented or rusty LP/Propane tank may be
hazardous and should be checked by your tank
supplier. Never use a cylinder with a damaged
valve. All tanks should be equipped with an OPD
(overfilling protection device). This is a DOT
requirement for all tanks purchased after 
October 1, 1998 and will ensure that the tank is
not overfilled. The LP/Propane tank should be a
standard 5-gal, 20 lb. gas cylinder tank
approximately 12” in diameter and 18” high
which must be constructed and marked in
accordance with the Specifications for LP/Propane
Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard
of Canada, CAN/CSA-B339, Cylinders, Spheres
and Tubes for Transportation of Dangerous
Goods; and Commission. The cylinder connection
device must be compatible with the Type 1,
QCC-1 connector on the outdoor cooking
appliance. 

All LP/Propane tanks must be mounted in a
vertical position for proper ventilation. The
cylinder must be provided with a shut-off valve
terminating in an LP/Propane gas supply cylinder
valve outlet specified. The cylinder supply system
must be arranged for vapor withdrawal and
provided with a listed overfilling prevention
device. If the appliance is stored indoors the
cylinder must be disconnected and removed from
the appliance. Each tank is supplied with a dust
cap. Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only install
the type of dust cap on the cylinder valve outlet
that is provided with the cylinder valve.

Other types of caps or plugs may result in
leakage of propane. The cylinder used must
include a collar to protect the cylinder valve.
Cylinders must be stored outdoors in a well-
vented area out of the reach of children.

Built-In Installations

Built-in installations must be plumbed using a
fixed/hard line if the unit is going to be operated
at a distance exceeding 3 feet (0.91 meters) from
the fuel supply per ANSI Z21.24 CSA. Also, in a
built-in construction where an LP/Propane tank is
going to be used, there 

MUST

be some type of

support (braces, cutout, etc.) to prevent tank from
moving within the installation. The support must
also allow the LP/Propane tank to withstand a
horizontal tipping force equal to the weight of 
the tank without tipping over. The tank can not
tip over or deflect more than 1.00 inch when a 
8 lb. horizontal force is applied to a 20 lb.
LP/Propane tank

26

Connection

Operating Pressure

1/2” (1.3 cm) NPT male with a 3/8” (.95) flare adapter

10.0” W.C.P. LP/Propane.

Summary of Contents for VGBQ1302

Page 1: ...tion Guide Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking website at vikingrange com F20896D EN 070113 Outdoor Gas Grills ...

Page 2: ...dian Electrical Code CSA C22 1 CAUTION Before placing into operation always check for gas leaks with a soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS DANGER WHAT TO DO IF YOU SMELL GAS Shut off gas to the appliance Extinguish any open flame Open lid If odor continues keep away from the appliance immediately call your gas supplier or your fire department FOR YOUR SAFETY DO NOT sto...

Page 3: ...lator assembly for connection to standard 5gal 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 100 Series Models 9 volt DC battery for electronic ignition 300 Series Models 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord wi...

Page 4: ...quirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable NA 30 000 BTU Nat LP 8 3 kW Nat LP Rotisserie burner rating 15 000 BTU Nat 13 500 BTU LP 4 4...

Page 5: ...al 1 2 1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW Nat LP Rotisserie bu...

Page 6: ... for the ignition system and canopy lights In addition the rotisserie motor requires a separate 110 120 volt supply to be located on the right hand side of the grill Both the power supply cords for the ignition lights and the rotisserie motor are equipped with a 3 prong grounded plug for protection against shock hazard Do not cut or remove the grounding from the plug The electrical service must be...

Page 7: ...bustable surface 6 15 2 cm Clearance Dimensions 100 and 300 Series 36 W Grill 13 22 15 16 58 3 cm 17 3 16 43 7 cm 10 5 8 26 9 cm 27 9 16 70 0 cm 8 20 3 cm 5 3 8 13 7 cm 27 13 16 70 6 cm 29 73 6 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface 6 15 2 cm Clearance Dimensions 100 and 300 Series 30 W Grill 12 VGBQ1302 VGBQ3302RE VGBQ1363 VGBQ3363RE ...

Page 8: ...0 cm to combustable surface 6 15 2 cm VGBQ54203RE VGIQ54203RE 15 14 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 29 1 2 74 9 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface 6 15 2 cm Clearance Dimensions 500 Series 30 W Grill Clearance Dimensions 500 Series 42 W Grill VGBQ53002RE ...

Page 9: ... on 300 Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Countertop typically requires 3 4 wide by 3 4 deep notch cutout on each side of grill This allows grill CP to sit back properly in the cutout Gas inlet and power cord location area 5 12 7 cm 5 12 7 cm 3 4 1 9 c m 3 4 1 9 c m 17 Cutout Dimensions 100 and 30...

Page 10: ... solid bottom to support the full weight of the unit Cutout Dimensions 500 Series 30 W Grill 19 10 1 8 25 7 cm 36 91 4 cm Access door opening 24 3 8 61 9 cm 35 1 4 89 5cm 3 7 6 cm min Electrical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on 300 Series to be located on rear wall with a maximum distance of 2 61 0 cm...

Page 11: ...lectrical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Gas inlet and power cord location area 5 12 7 cm 5 12 7 cm Countertop typically requires 1 2 wide by 1 2 deep notch cut...

Page 12: ...han 1 00 inch from inside floor of installation Vents located on sidewall Ventilation for Built In Installations An enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure The effectiveness of the opening s for purposes of ventilation shall be determined with the LP gas supply cylinder in place This shall be accompanied by one of the fol...

Page 13: ...mbly Natural Fixed Piping Connection Check with your local gas utility company or with local codes for instructions on installing gas supply lines Be sure to check on type and size of run and how deep to bury the lines If the gas line is too small the grill will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 7 8 2 2 cm female flare ...

Page 14: ...led The LP Propane tank should be a standard 5 gal 20 lb gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP Propane Gas Cylinders of the U S Department of Transportation D O T or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission The c...

Page 15: ... one part liquid detergent and one part water You will need a spray bottle brush or towel to apply the solution to the fittings Note For LP Propane units check with a full cylinder Check that all control knobs are in the OFF position 4 Apply the soap solution to fittings Turn cylinder valve knob counter clockwise one turn to open Although all gas connections on the grill are leak tested at the fac...

Page 16: ... following Must push ignition button on 100 Series Note By replacing the knob it may be easier to light the burner A qualified installer should perform the following burner adjustments Each burner is tested and adjusted at the factory prior to shipment however variations in the local gas supply may make it necessary to adjust the burners The flames of the burners except the rotisserie infrared bur...

Page 17: ...ved skewer bushing should rest on the left side bracket Do not remove the plastic cover on the rotisserie motor switch due to safety consideration 32 WARNING ELECTRICAL SHOCK HAZARD This appliance is equipped with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug Groov...

Page 18: ...th the pullout drip tray on the left hand side Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase __________________________________________________________________________________ Date installed ________________________________________...

Reviews: