Viking VCIH3608 Installation Manual Download Page 11

21

20

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop

with gas char-grill. Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE:

Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be

hard wired with 2-wire with ground. An interior or exterior-power ventilator kit must be purchased for
installation with all 18”H. hoods.

Dimensions & Specifications

30

(76

.2

cm

)

C

A

18”

(45.7

cm

)

B

6“

(15.2

cm

)

C (Hood width)

36”W.  

  35-7/8” (91.1 cm)

42”W.  

  41-7/8” (106.4 cm)

54”W.  

  53-7/8” (136.8 cm)

66”W.  

  65-7/8” (167.3 cm) 

B (Duct height)

36”W.  
42”W.
54”W.
66”W. 

12” (30.5 cm)

or

24” (61.0 cm)

or

36” (91.4 cm)

A (Duct width)

36”W.  

 

12” (30.5 cm)

42”W.  

 

12” (30.5 cm)

54”W.  

 

18” (45.7 cm)

66”W.  

 

24” (70.0 cm) 

30”

min

.

(76.2

cm

)

to

36”

max

.

(91.4

cm

)

66”

min

.

(167

.6 c

m)

to

72”

max

.

(182

.9 c

m)

36

(91

.4

cm

)

Clearance Dimensions

VCIH Chimney Island Hoods

Description

36”

42”

54”

66”

Duct cover width

12” (30.5 cm)

12” (30.5 cm)

18” (45.7 cm)

24” (70.0 cm)

Duct cover depth

12” (30.5 cm)

Duct cover height

12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)

Number of lights

4

4

6

8

Number of filters

4

4

6

8

Heat lamps

N/A

Interior ventilator kits

DIV600

DIV600

DIV1200*

DIV1200*

Exterior ventilator kits

DEV900/1200”*

DEV900/1200*/1500**

DEV1200*/1500**

DEV1200*/1500**

Interior duct size

7” (17.8 cm)

7” (17.8 cm)

10” (25.4 cm)

10” (25.4 cm)

Exterior duct size

10” (25.4 cm)

Interior—Maximum amps

3.9

4.7

8.6

9.5

Exterior—Maximum amps

6.6/3.9

7.4/4.8/5.5

5.6/6.4

6.5/7.3

(VCIH Chimney Island Hoods)

NOTE:

Optional duct cover sold separately.

(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)

Summary of Contents for VCIH3608

Page 1: ...ng Installation Guide Professional Hoods Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking...

Page 2: ...should leave these instructions with the consumer who should retain for local inspector s use and for future reference Check with a qualified and trained installer or local codes for makeup air requir...

Page 3: ...burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if You know it is a Class ABC extinguisher and you already know how to op...

Page 4: ...m 7 17 8 cm dia duct location Electrical hookup 1 2 1 3 cm 4 10 2 cm 3 1 2 8 9 cm A 24 W 23 7 8 60 6 cm 30 W 29 7 8 75 9 cm 36 W 35 7 8 91 1 cm B 24 W 5 1 4 13 3 cm 30 W 8 1 4 20 9 cm 36 W 11 1 4 28 6...

Page 5: ...min 76 2 cm to 36 max 91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 36 91 4 cm Clearance Dimensions VWH 18 H Wall Hoods Description 24 30 36 42 48 54 60 66 Duct cover width 23 7 8 29 7 8 35 7 8 41 7 8 47...

Page 6: ...15 1 cm 9 3 4 24 8 cm 2 1 2 6 35 cm 6 5 8 16 8 cm 3 7 62 cm 8 3 16 20 7 cm B A 24 W 11 15 16 30 3 cm 30 W 14 15 16 37 9 cm 36 W 17 15 16 45 6 cm 42 W 20 15 16 53 2 cm 48 W 23 15 16 60 8 cm 54 W 26 15...

Page 7: ...purchased for installation with all 18 H hoods 30 min 76 2 cm to 36 max 91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 36 91 4 cm Clearance Dimensions VCWH Chimney Wall Hoods Description 30 36 42 48 54 60...

Page 8: ...60 W 29 15 16 76 0 cm 66 W 32 15 16 83 7 cm C 48 W 18 45 7 cm 54 W 18 45 7 cm 60 W 24 61 0 cm 66 W 24 61 0 cm 10 25 4 cm dia duct location 6 15 2 cm 1 1 2 3 8 cm 1 1 2 3 8 cm A B C 120 V power supply...

Page 9: ...t must be purchased for installation with all 18 H hoods 30 min 76 2 cm to 36 max 91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 36 91 4 cm Clearance Dimensions VIH Island Hoods Description 36 42 54 66 Du...

Page 10: ...lation for all Island Hoods B A 8 3 16 20 7 cm 2 1 2 6 35 cm 6 5 8 6 35 cm 3 7 62 cm 120 V 5 15 16 15 1 cm 9 3 4 24 8 cm 10 25 4 cm dia duct location A 36 W 17 15 16 45 6 cm 42 W 20 15 16 18 2 cm 54 W...

Page 11: ...4 61 0 cm or 36 91 4 cm A Duct width 36 W 12 30 5 cm 42 W 12 30 5 cm 54 W 18 45 7 cm 66 W 24 70 0 cm 30 min 76 2 cm to 36 max 91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 36 91 4 cm Clearance Dimensions...

Page 12: ...7 cm 66 W 24 61 0 cm 1 1 8 2 9 cm 1 1 8 2 9 cm 10 25 4 cm dia duct location B A C 6 15 2 cm 120 V power supply B 54 W 53 7 8 136 8 cm 66 W 65 7 8 167 3 cm 10 25 4 cm dia duct location 12 30 5 cm 1 1 8...

Page 13: ...hown Adjust your measurements for various heights of ceilings soffits cabinets or ranges rangetops Check Framing NOTE Because of the weight of the hood make sure that the mounting screws are driven in...

Page 14: ...up then slide back over rear lip Slide filter front over front lip Push filter rear up then slide back over rear lip 2 1 3 10 1 2 Remove damper and discard with transition Turn recirculating unit upsi...

Page 15: ...lter rear up then slide back over rear lip 1 2 3 13 Slide spacer front over front lip Push spacer rear up then slide back over rear lip 1 2 3 12 5 Remove electrical box cover 1 6 2 Flip hood over Inse...

Page 16: ...y CAUTION If not using a duct cover using screws provided make sure top mounting screws are secured into soffit or cabinet framing use additional mounting screws if necessary To install ventillation k...

Page 17: ...unting bracket Attach duct cover to ceiling The ceiling bracket can be hidden by using a locally supplied trim A2 5 16 nut driver B1 Additional support option Drill holes in all four corners for threa...

Page 18: ...nopy to duct cover soffit Seal top of hood to duct with aluminum tape 3 To install ventillation kit refer to ventillation kit installation instructions Run duct work down to bottom edge of duct cover...

Page 19: ...d below You will need it if service is ever required The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy Model number...

Page 20: ......

Reviews: