![Viking VCIH3608 Installation Manual Download Page 11](http://html1.mh-extra.com/html/viking/vcih3608/vcih3608_installation-manual_1025855011.webp)
21
20
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop
with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be
hard wired with 2-wire with ground. An interior or exterior-power ventilator kit must be purchased for
installation with all 18”H. hoods.
Dimensions & Specifications
30
”
(76
.2
cm
)
C
A
18”
(45.7
cm
)
B
6“
(15.2
cm
)
C (Hood width)
36”W.
35-7/8” (91.1 cm)
42”W.
41-7/8” (106.4 cm)
54”W.
53-7/8” (136.8 cm)
66”W.
65-7/8” (167.3 cm)
B (Duct height)
36”W.
42”W.
54”W.
66”W.
12” (30.5 cm)
or
24” (61.0 cm)
or
36” (91.4 cm)
A (Duct width)
36”W.
12” (30.5 cm)
42”W.
12” (30.5 cm)
54”W.
18” (45.7 cm)
66”W.
24” (70.0 cm)
30”
min
.
(76.2
cm
)
to
36”
max
.
(91.4
cm
)
66”
min
.
(167
.6 c
m)
to
72”
max
.
(182
.9 c
m)
36
”
(91
.4
cm
)
Clearance Dimensions
VCIH Chimney Island Hoods
Description
36”
42”
54”
66”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
Number of lights
4
4
6
8
Number of filters
4
4
6
8
Heat lamps
N/A
Interior ventilator kits
DIV600
DIV600
DIV1200*
DIV1200*
Exterior ventilator kits
DEV900/1200”*
DEV900/1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
3.9
4.7
8.6
9.5
Exterior—Maximum amps
6.6/3.9
7.4/4.8/5.5
5.6/6.4
6.5/7.3
(VCIH Chimney Island Hoods)
NOTE:
Optional duct cover sold separately.
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
Summary of Contents for VCIH3608
Page 20: ......