Two 2”x 4” Mounting Boards

3” (7.6 cm) x 3-1/2” (8.9 cm)

NOTE:

 If unit is installed deeper than

24” (61.0 cm), then shim behind the mounting

board by the difference.

NOTE:

 If unit is installed deeper than

24” (61.0 cm), then shim behind the mounting

board by the difference.

One 2”x 4” Mounting Board
3” (7.6 cm) x 3-1/2” (8.9 cm)

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.

NOTE:

 Top of unit must be placed firmly under anti-tip board.

  

Anti-Tip Location

Flush Mount

 Anti-Tip Location

79–3/8”

(201.6 cm) min.

to bottom of 
anti-tip boar

d

80–1/2”

(204.6 cm) max.

to bottom of 
anti-tip boar

d

41”

(104.1 cm)

3–1/2”

(8.9 cm)

3”

(7.6 cm)

41”

(104.1 cm)

3–1/2”

(8.9 cm)

1-1/2”

(3.8 cm)

Anti-Tip Dimensions 

(Side-By-Side)

13

9

(22.9 cm)

73-3/

8”

(186.4 cm)

8

2–7/

8”

(210.5 cm) min.

anti-tip boar

d &

opening height

8

4–1/16

(213.5 cm) max.

anti-tip boar

d &

opening height

47–5/

8”

(121.0 cm) min.

to

47–3/4

(121.2 cm) max.

4

8”

(121.9 cm)

Flush Mount only

24

(61.0 cm)

Electric Outlet Location

Water Line Entry Area

6–3/4

(17.1 cm)

7–5/

8”

(19.4 cm)

3

(7.6 cm)

5/

8”

(1.6 cm)

5/

8”

(1.6 cm)

10–1/2

(26.7 cm)

5/

8”

(1.6 cm)

10–3/4

(27.3 cm)

1

(2.5 cm)

3–5/

8”

(9.2 cm)

Optional floor 

water line entry

47–5/

8”

(121.0 cm)

4

8”

(121.9 cm)

Flush Mount only

See Anti-Tip boar

d installation

  

  

6

(15.2 cm)

9

(22.9 cm)

Cutout Dimensions 

(Side-By-Side)

12

48” Side-By-Side

48” Side-By-Side

Summary of Contents for VCBB5362R

Page 1: ...ississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com F21250 EN 080113 UL C UL Professional Built in Bottom Freezer and Side by...

Page 2: ...____ 18 Cabinet Information Professional with flush mount trim _______________________________ 20 Custom Side Panel Dimensions Professional _________________________________________ 22 Custom Side Pan...

Page 3: ...alve 6 8 x 3 7 6 cm wood screws longer screws may be required 1 Saddle valve do not use self piercing feature of the valve assure that floor will support unit door panels and contents approximately 12...

Page 4: ...from bottom 82 3 4 210 2 cm min to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 22 3 16 56 4 cm To front of top grille 24 61 0 cm To front of handle endcap 26 1 2 67 3 cm Cu...

Page 5: ...9 cm Overall height from bottom 82 3 4 210 2 cm min to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of handle endc...

Page 6: ...0 1 2 204 6 cm max to bottom of anti tip board 35 88 9 cm 3 1 2 8 9 cm 3 7 6 cm 35 88 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Side By Side 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min ant...

Page 7: ...1 2 204 6 cm max to bottom of anti tip board 41 104 1 cm 3 1 2 8 9 cm 3 7 6 cm 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Side By Side 13 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min a...

Page 8: ...to 84 1 16 213 5 cm max Overall depth from rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of handle endcap 26 1 2 67 3 cm Cutout wdth 36 91 4 cm Cutout heigh...

Page 9: ...204 6 cm max to bottom of anti tip board 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Bottom Freezer 17 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm mi...

Page 10: ...cm Space if 24 standard cabinet depth is used Door 24 61 0 cm Standard Cabinet Depth Wall 3 4 1 9 cm Full End Panel 1 3 4 4 4 cm Offset Partial Overlay Cabinet Door Cabinet Information Professional 18...

Page 11: ...4 1 9 cm Full End Panel 3 4 1 9 cm space if 24 61 0 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm space if 25 63 5 cm cabinet depth is used Flush 2...

Page 12: ...Mount Trim 23 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 61 0 cm 6 15 2 cm Optional kickplate Notch dimensions determined by cabinets 82 7 8...

Page 13: ...ble to support two horizontally mounted 2X4s included bolted to two wall studs The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction Remove anything attached to rear or side walls tha...

Page 14: ...carton rear approximately 1 4 0 6 cm to 1 2 5 cm from right corner with a utility knife extended 1 4 0 6 cm 4 Remove carton and exterior packaging Save cardboard shipping material to protect floor sur...

Page 15: ...off Connect supply tube to water valve using a 1 2 wrench NOTE DO NOT overtighten 28 Remove four side screws and remove unit top Loosen the four hinge screws Adjust door Retighten four hinge screws Re...

Page 16: ...rew and place in 90 or 120 position 30 Lift unit off rollers to desired height and level unit using a 5 16 head wrench NOTE DO NOT use an electric device Overtightening can cause damage Attach positiv...

Page 17: ...rocedures and guidelines Installation instructions parts and service availability and standard warranty are included with the product when shipped This drinking water system must be maintained accordi...

Page 18: ...nd verify unit is secure Position unit in cutout level at desired height and secure unit Plug in unit and verify operation Connect water supply if applicable Verify icemaker fill tube is properly inse...

Page 19: ...problems contact Viking Range LLC at 1 888 845 4641 or write to VIKING RANGE LLC PREFERRED SERVICE 111 Front Street Greenwood Mississippi 38930 USA Record the following information indicated below You...

Page 20: ...39 38...

Reviews: