
16
ON
OFF
SET
WARMER
COLDER
˚̊
F/C
PRESS AND HOLD
POWER FAILURE - Flashing Amber
HIGH/LOW TEMP - Red
PRESS ON/OFF - Reset
ALARMS OFF - Steady Amber
TruProtect System
38˚
F
Fu
un
nccttiio
on
n
F
Fu
un
nccttiio
on
n A
Acccce
essss
S
Sh
ho
ow
w R
Ro
oo
om
m M
Mo
od
de
e
S
Se
errvviicce
e D
Diia
ag
gn
no
ossttiiccss
“
“E
En
ntte
err”
” a
an
nd
d “
“E
Exxiitt”
” S
Se
errvviicce
e D
Diia
ag
gn
no
ossttiiccss m
mo
od
de
e b
byy p
prre
essssiin
ng
g a
an
nd
d h
ho
olld
diin
ng
g tth
he
e
kke
eyyp
pa
ad
d
w
wh
hiille
e p
prre
essssiin
ng
g tth
he
e
kke
eyyp
pa
ad
d 4
4--ttiim
me
ess w
wiitth
hiin
n 5
5--sse
ecco
on
nd
dss.. S
Se
errvviicce
e D
Diia
ag
gn
no
ossttiiccss m
mo
od
de
e
a
allsso
o w
wiillll a
au
utto
om
ma
attiicca
allllyy e
exxiitt a
afftte
err 5
5--m
miin
nu
utte
ess o
off n
no
o kke
eyyp
pa
ad
d e
en
nttrryy..
D
Diissp
plla
ayy E
Errrro
orr C
Co
od
de
e R
Re
effe
erre
en
ncce
e::
T
Th
he
e m
miiccrro
op
prro
occe
esssso
orr iin
n tth
he
e cco
on
nttrro
oll cco
on
nttiin
nu
ua
allllyy m
mo
on
niitto
orrss ccrriittiicca
all rre
effrriig
ge
erra
attiio
on
n ssyysstte
em
m
cco
om
mp
po
on
ne
en
nttss ffo
orr p
prro
op
pe
err o
op
pe
erra
attiio
on
n.. IIff cco
om
mp
po
on
ne
en
ntt p
pa
arra
am
me
ette
errss e
exxcce
ee
ed
d n
no
orrm
ma
all o
op
pe
erra
attiin
ng
g
ssp
pe
ecciiffiicca
attiio
on
nss,, tth
he
e d
diissp
plla
ayy w
wiillll a
au
utto
om
ma
attiicca
allllyy fflla
assh
h tth
he
e rre
essp
pe
eccttiivve
e e
errrro
orr cco
od
de
e a
ass ffo
ollllo
ow
wss::
P
Plle
ea
asse
e cca
allll a
a q
qu
ua
alliiffiie
ed
d sse
errvviicce
e tte
ecch
hn
niicciia
an
n iiff a
an
nyy o
off tth
he
esse
e cco
od
de
ess a
arre
e d
diissp
plla
ayye
ed
d..
ON
OFF
SET
WARMER
COLDER
˚̊
F/C
55˚
F
LIGHT
13˚
C
38˚
F
4˚
C
SA
ON
OFF
SET
WARMER
COLDER
˚̊
F/C
55˚
F
LIGHT
13˚
C
38˚
F
4˚
C
SA
TruProtect
™
“Advanced” Function “Quick” Reference
ON
OFF
SET
WARMER
COLDER
˚̊
F/C
55˚
F
LIGHT
13˚
C
38˚
F
4˚
C
SA
E
En
na
ab
blle
e tth
he
e S
Sh
ho
ow
w R
Ro
oo
om
m M
Mo
od
de
e b
byy p
prre
essssiin
ng
g a
an
nd
d h
ho
olld
diin
ng
g tth
he
e
kke
eyyp
pa
ad
d w
wh
hiille
e
p
pe
errffo
orrm
miin
ng
g a
a “
“P
Po
ow
we
err O
On
n R
Re
esse
ett”
”,, ((P
PO
OR
R)),, ii..e
e.. -- d
diisscco
on
nn
ne
ecctt a
an
nd
d rre
ecco
on
nn
ne
ecctt tth
he
e p
po
ow
we
err
ssu
up
pp
pllyy tto
o u
un
niitt.. E
Exxiitt S
Sh
ho
ow
w R
Ro
oo
om
m M
Mo
od
de
e b
byy iin
niittiia
attiin
ng
g a
a P
PO
OR
R o
on
nllyy..
E1
E2
E3
E4
Compressor fault, (high/low amps).
Condenser fan motor fault, (high/low amps).
Evaporator thermistor “sensor B” fault, (out-of-range).
Display thermistor “sensor A” fault, (out-of-range).
SERVICE DIAGNOSTICS
Summary of Contents for Undercounter/Freestanding Refrigerated Drawer
Page 1: ...Viking Use Installation Guide Undercounter Freestanding Refrigerated Drawer ...
Page 5: ...5 Side View 26 7 8 68 3 cm 24 3 8 61 9 cm 22 55 9 cm 46 7 8 119 0 cm 48 3 4 123 8 cm ...
Page 7: ...7 Side View 26 7 8 68 3 cm 24 3 8 61 9 cm 22 55 9 cm 46 1 2 118 1 cm 48 3 4 123 8 cm ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 23: ...23 ...