29
RDMOS201SS
Terminal
Push
Pull down
1
2
Lever
Positive lock¨
connector
CONTROL PANEL ASSEMBLY REMOVAL
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-2. Positive lock
®
connector
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU.
1. Disconnect the power supply cord and remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the oven lamp from the oven lamp socket.
5. Pull the wire leads from the oven lamp socket by pushing
the terminal hole of the oven lamp socket with the small
flat type screw driver.
6. Remove the oven lamp socket from the magnetron duct
by turning the socket counterclockwise.
7. Remove the oven lamp from the socket by turning the
oven lamp.
8. Now, the oven lamp and the oven lamp socket are
free.
OVEN LAMP AND LAMP SOCKET REMOVAL
Figure C-1. Oven lamp socket
Oven lamp
socket
Terminal
1. Disconnect the power supply cord and then remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from panel components.
5. Remove the one (1) screw holding the control panel
assembly to the oven cavity front plate.
6. Slide the control panel assembly upward and remove it.
7. Now, individual components can be removed.
CPU REMOVAL
1. Disconnect the power supply cord and then remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the four (4) screws holding the control unit to the
control panel frame. Unplug key unit ribbon cable from the
control unit.
Control panel frame
Key unit/Membrane switch
CPU assembly
Summary of Contents for RDMOS201SS