34
E
Charcoal Filter
Charcoal Filter, which was installed in your Built-in Microwave Hood,
is used for nonvented, recirculated installation. The filter should be
changed every 6 to 12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or by
unplugging.
2. Remove the two top louver mounting screws. (See illustration.)
3. Pull the louver away from the unit.
4. Remove the charcoal filter holder by removing the center mounting
screw.
5. Change the charcoal filter.
6. Replace the filter holder and center mounting screw.
7. Carefully push the louver back into place and replace the screws
removed in step 2.
Louver
Charcoal filter
(white side faces front)
Screw
Screw
Screw