To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit. Ensure all
ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Disassembly
8
©2012 Viking Preferred Service
Infinite Switch Removal
1.
Remove smooth top assembly, see Page
7.
2.
Remove faulty infinite switch wiring
one connection at a time. Install each
connection on new switch as it is removed
from faulty switch.
Element Removal
1.
Remove smooth top assembly, see Page
7.
2. Remove faulty element by releasing tabs
on bottom of element.
3.
Remove one wire at a time, transferring
the wires to the new element as they are
removed from the faulty element.
4.
Verify new element mounting tabs match
old element and reattach in the same
location in the burner box. Failure to
position new element in same alignment
as old element could result in poor
performance.