Operation
Programming
The red LED on the front of the
PRX-4
will light steady to show the keypad is powered up,
and blink yellow with each key stroke. A beep tone will also acknowledge each time a key
is pressed. To gain access, enter the keyless entry code, followed by the “
#
” key.
Important:
26-bit Wiegand data limits the entry code range from 00001 to 65534.
Warning:
Do not program the Viking
ES-1
,
C-4000
,
AES-2000
or any other entry system
to accept code number 65535. The
PRX-4
keypad outputs 65535 as an error code. An
error code is given if one of these three sequences happen:
1.
Pressing the “#” key with no preceding digits.
2.
Pressing any number of only zeros prior to pressing the “#” key.
3.
Pressing 65535 or any number above 65535.
The
PRX-4
is factory programmed with the facility code cleared (000). To program a facility
code, press “
Q
” during the first 3 seconds from when the unit powers up. Then (within 10
seconds) enter any number 000 to 255 as its facility code, followed by “
#
”.