background image

         2” 

(5.1 cm)

Dia.

   2-3/4”

 (7.0 cm)

4-3/8”

(11.1 cm)

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

31-1/16”

(78.9 cm)

28-5/16”

(71.9 cm)

23-7/16”

(59.5 cm)

Gas or Electrical
connection in
this area

Gas connection 
in this area

VGSC307-4B

VGSC367-6B

VGSC367-4G

VGSC367-4Q

Surface burner rating

Four grated burners (each)

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

15,000 BTU Nat. (4.4 kW)/

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

13,500 BTU LP (4.0 kW)

Six grated burners (each)

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One griddle

15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)

One grill

18,000 BTU Nat. (5.3 kW)–gross/
16,000 BTU LP (4.7 kW)

Broil burner rating

18,000 BTU Nat. (5.3 kW)/16,000 BTU LP (4.7 kW)

Bake burner rating

3 0 ,000 BTU Nat./LP (8.8 kW)

VGSC307-4B

30”W. Four-Burner

Range

VGSC367-6B 

36”W. Six-Burner

Range

VGSC367-4G

36”W. Four-Burner/

Griddle Range

VGSC367-4Q

36”W. Four-Burner/

Grill Range

COOKING

Professional Freestanding Gas Self-Clean 30”/36”W. 

Sealed Burner Range

P L A N N I N G   A N D   D E S I G N   G U I D E

V I K I N G R A N G E . C O M       •       1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7   V R C — I N F O R M AT I O N   S U B J E C T   T O   C H A N G E

UTILITY

REQUIREMENTS

GAS

• Shipped natural gas

standard; field convert
to LP/propane with
optional accessory kit
or order as LP by
adding LP after color
code

• Accepts standard

residential 1/2” ID gas
service line

• Gas manifold pressure 
• Natural gas 5.0” W.C.P. 
• LP/Propane 10.0”

W.C.P.

ELECTRICAL

• Four-foot (121.9 cm)

cord included with
range

• Three-wire with

ground/three-prong
plug

• 120 V/60 Hz
• Maximum amp 

usage—
o 4B—2.3
o 6B—2.3
o 4G—6.0
o 4Q—2.4

PLUMBING

Not applicable

Installation Requirements

ACCESS REQUIREMENTS

Note: 

If the gas supply is installed through the rear wall, the location MUST be 31-1/16” (78.9 cm) above the

floor and 2-3/4” (7.0 cm) from the left hand side (when facing the unit) or within a maximum of 4-3/8” (11.1
cm) above the floor as specified in the drawing above.