TROUBLESHOOTING GUIDE (con’t)
PROBLEM POSSIBLE CAUSE CORRECTION
4. No Power from
4. Check E15 to ground (See
Control Board
page 14).
I.
Control Panel
1. Control Panel Ribbon
1. Check control panel ribbon
Keys Inoperative or
Cable Plugged in
cable (silver area on the ribbon
Malfunctioning
Wrong
cable terminal should be
facing
away
from
the
control
board). Plug in correctly if
Incorrect.
2. Control Panel or Ribbon
2. Check E2 test points page 14.
Cable Defective (Or)
No Signal Read at
Control
Board.
J. LED’s Do Not
1. Unit Switched Off
1. Press unit On/Off key
Illuminate.
2.
LED
Ribbon
Cable
2. Check LED ribbon cable. Plug
Plugged in Wrong.
in correctly if incorrect.
3. No Data from Control
3. Replace control board.
Board.
K. All LED’s Stay
1. Bad Data from Control
1. Replace control board.
Illuminated.
Board.
L. Same Segment(s)
1. Bad Data from Control
1. Replace control board.
Missing From All
Board.
Display Windows
M. Segment(s) Miss-
1. Bad LED Board in
1. Replace control panel assembly.
Ing From Only one
Control
Panel.
Display Window.
N. Door or Unit
1. See Page 12 this Manual
1. See page 12 this manual.
25