Note: The unit can also be powered
by 24-48V DC PABX battery supply on
terminals 50 and 25.
Installation
Note: Loop start and ground start CO lines may be combined on the
PF-6A (see Programming). When ground start lines are used, pin 50
(V/S) must be connected to a good earth ground.
It is recommended that the first six C.O. lines be interfaced with the
PF-6A as shown in the chart to the right.
If your system has an alarm contact or manual transfer switch, you
must connect it to the red and green wires of the modular jack labeled
EXTERNAL ALARM on the left side of the PF-6A. This must be a
normally open maintained contact closure. If normally closed alarm
contacts are used, wire them to break the power to the PF-6A when
they open.
Important: This unit is not protected against damage from power line surges. A surge protector is recommended if
operated on 120V AC.
A. Power Fail Bypass Unit
Circuit 4
Circuit 5
Circuit 6
BK/G
G/BK
BK/BN
BN/BK
BK/S
S/BK
Y/BL
BL/Y
Y/O
O/Y
Y/GN
GN/Y
Y/BN
BN/Y
Y/S
S/Y
V/BL
BL/V
V/O
O/V
V/GN
GN/V
V/BN
BN/V
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
T4T-IN
T4R-IN
T4T-OUT
T4R-OUT
S4T-IN
S4R-IN
S4T-OUT
S4R-OUT
T5T-IN
T5R-IN
T5T-OUT
T5R-OUT
S5T-IN
S5R-IN
S5T-OUT
S5R-OUT
T6T-IN
T6R-IN
T6T-OUT
T6R-OUT
S6T-IN
S6R-IN
S6T-OUT
S6R-OUT
T1T-IN
T1R-IN
T1T-OUT
T1R-OUT
S1T-IN
S1R-IN
S1T-OUT
S1R-OUT
T2T-IN
T2R-IN
T2T-OUT
T2R-OUT
S2T-IN
S2R-IN
S2T-OUT
S2R-OUT
T3T-IN
T3R-IN
T3T-OUT
T3R-OUT
S3T-IN
S3R-IN
S3T-OUT
S3R-OUT
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
W/BL
BL/W
W/O
O/W
W/G
G/W
W/BN
BN/W
W/S
S/W
R/BL
BL/R
R/O
O/R
R/G
G/R
R/BN
BN/R
R/S
S/R
BK/BL
BL/BK
BK/O
O/BK
Line
Pins
Color
Trunk/station
Trunk 1 - IN
Trunk 1 - OUT
Station 1 - IN
Station 1 - OUT
Trunk 2 - IN
Trunk 2 - OUT
Station 2 - IN
Station 2 - OUT
Trunk 3 - IN
Trunk 3 - OUT
Station 3 - IN
Station 3 - OUT
Circuit
Circuit 1
Circuit 2
Circuit 3
Station or trunk
control line
GND
-24/48V
50
25
V/S
S/V
Trunk 4 - IN
Trunk 4 - OUT
Station 4 - IN
Station 4 - OUT
Trunk 5 - IN
Trunk 5 - OUT
Station 5 - IN
Station 5 - OUT
Trunk 6 - IN
Trunk 6 - OUT
Station 6 - IN
Station 6 - OUT
Test Button
Dip Switches
RJ21X Female Connector
POWER and ACTIVE LED - The POWER LED and the ACTIVE LED
will be lit when the PF-6A is in the normal operating mode. The
ACTIVE LED will go out and the POWER LED will stay lit when the test
button is pressed.
VIKING
©
MODEL PF-6A
VIKING ELECTRONICS, INC. HUDSON, WI 54016
AUTOMATIC LINE
TRANSFER SWITCH
RJ21X
POWER ACTIVE
TEST
1 2 3 4
EXTERNAL
ALARM
RJ21X Male
Connector
(not included)
VIKING
©
MODEL PF-6A
VIKING ELECTRONICS, INC. HUDSON, WI 54016
AUTOMATIC LINE
TRANSFER SWITCH
RJ21X
POWER ACTIVE
TEST
1 2 3 4
EXTERNAL
ALARM
PABX/KSU
C.O. Line
Normally Open
Maintained
Contact Input
Normally Open
Contact Input