Front View of Optional

VE-5x5 (not included)

2.25”

Condensation

Drain Hole 

*

 Adhere gasket to front panel,

   centering over mounting holes

5.14”

5.22”

3.25”

Call

4.0"

Rear View of VE-5x5

(not included)

Push to Call Button

Blue LED Power Indicator

Condensation Drain Hole

(4) 6-32 X 3/4” stainless steel, flat 
head, hexdrive, screws (included)

5.0”

MSB-1-EWP

shown with 

Viking Model 

VE-GNP 

Gooseneck

Pedestal

(4) 0.38” diameter
(for gooseneck mounting)

(4) 0.2 x 0.43 slots
for double gang box

(2) 0.2 x 0.43 slots
for single gang box

(1) 0.74" dia

3.0” 3.3”

3.0”

2.1”

Wa

ll

S

tud

Front View of 

Plastic Rough-In

Box (included)

Wire knock out

(2) Standard flat head dry wall 
(sheet rock) screws (not included)

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

The optional 

VE-5x5

Surface Mount Box is designed

to be surface mounted to a single gang box, double
gang box or 

VE-GNP

gooseneck pedestal (right). For

more information on the 

VE-5x5

and 

VE-GNP

see

DOD# 424

.

Important:

The 

MSB-1

will 

NOT

mount to a standard double gang box.  

Caution:

When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To pre-

vent condensation from accumulating inside the 

MSB-1

always bring conduit into the bottom of the unit. If this is not possible, drill

a 1/4” diameter hole in the bottom of the gray plastic box.

*Note:

Peel off paper liner and adhere gasket to the back of the faceplate, centering it over the four corner mounting holes. Be care-

ful to position the modular jack inside the chassis as not to damage the components on the circuit board.

Note:

The plastic rough-in box (part # 

259576

) may be purchased separately

in advance. Go to 

www.vikingelectronics.com

and click on “

Spare Parts

”. 

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet

and the telephone line.  It is recommended that a surge protector be installed to protect against such surges.

!

A. Mounting

3

B. Wiring

Each of the 

MSB-1

’s features can be used a’ la carte. So depending on your application, connect only the features that

are needed.

1. 

If microphone audio is needed, connect the MIC AUDIO OUT screw terminals to the camera’s Line Level Audio In

connections.

2.

If arrival notification is needed, connect the PUSH BUTTON screw terminals to a trigger or alarm input, or use in

place of an existing doorbell.

3. 

If controlling the front panel blue LED light is needed, connect the LED CONTROL screw terminals to a normally

open set of contacts. The blue LED will go dark when the contacts are closed. The LED CONTROL contacts can also
be connected directly to the PUSH BUTTON contacts to make the blue LED wink off when the “CALL” button is
pressed. 

If the camera has a motion sensing feature that is used for detecting the arrival of a person, the PUSH BUTTON screw
terminals can still be connected to the LED CONTROL screw terminals to give appearance the “CALL” button is func-
tional when pressed.

4. 

If additional speaker volume is needed, connect the AUX SPEAKER screw terminals to up to three 8 ohm speakers. 

5. 

If speaker audio is needed, connect the AUDIO IN screw terminals to the camera’s Line Level Audio Output.

6. 

When all else is wired, connect the 12-15V AC OR DC screw terminals to the provided power supply adapter.

Summary of Contents for MSB-1

Page 1: ...on is pressed The MSB 1 EWP adds Enhanced Weather Protection EWP Use for outdoor installations where the unit is exposed to precipitation or condensation EWP products feature foam rubber gaskets and boots sealed connections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards with internally sealed field adjustable trim pots For more information see DOD 859 F Fe ...

Page 2: ...ameter holes to prevent punctures from paperclips etc Faceplate 14 gauge Marine grade 316 stainless steel faceplate and push button switch sealed per IP67 Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Condensation Drain Hole Mounting Screws 4 6 32 x 3 4 Marine grade 316 stainless steel flat head 5 64 hexdrive screws included LED Lights blue...

Page 3: ... circuit board Note The plastic rough in box part 259576 may be purchased separately in advance Go to www vikingelectronics com and click on Spare Parts IMPORTANT Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect against such surges A Mounting 3 B Wiring...

Page 4: ...hat is amplified with an on board 2 watt amplifier to drive the MSB 1 s internal speaker The speaker volume can be adjusted with the volume control labeled SPEAKER as shown on the Features Overview page 3 AUX SPEAKER is an additional speaker output driven from the same 2 watt internal amplifier that can drive up to an additional three 8 ohm speakers Viking models 30AE and 35AE ceiling speakers can...

Reviews: