Viking MLC-24 Technical Practice Download Page 3

Group Number

Assignment

1 - 24

25 - 48

49 - 72

73 - 96

   2

OFF

OFF

ON

ON

RJ21 Female 
Connector
(not included)

RJ21 Male 
Connector
(not included)

B.  Electronic or Digital Phone Installation with LM-2 Message Waiting Lamps

Station/Trunk Switch - Switch to STATION when
connecting the "control line" to a C.O. line or an analog
PABX/KSU station.  Switch to TRUNK when connecting the
"control line" to a dedicated phone or unused (loop start)
trunk input.

Neon/LED Switch - Switch to LED when using an LED or
LM-2 on a separate pair.

Green

Red

Reset Button

25T1
25R1

50
25

V/S
S/V

KSU/Digital Phone with LM-2

VIKING

©

MODEL MLC-24

VIKING ELECTRONICS, INC.  HUDSON, WI  54016

MESSAGE WAITING

LAMP CONTROLLER

RJ21X

FEMALE

RJ21X
MALE

J1

J2

STATION

COM

RESET

TRUNK

NEON

LED

POWER

1    2     3    4

A.  Assigning Group Lamp Numbers

Additional MLC-24’s can be added for controlling
up to 96 message waiting lights.  Set the dip
switches as shown below.

Dip Switch

   1

OFF

ON

OFF

ON

B.  Other Dip Switch Settings

Switch

3

3

4

4

ON

OFF

ON

OFF

Feature

When using hard wired LED’s

Use with LM-1’s, LM-2’s or message 
waiting phones 

Test pattern or diagnostics

Normal operation

Dip switch 3 and 4 can be used to set message
waiting light parameters and operational modes.

13
14
15
16
17
18
19
20
21
22
23
24

Pins

Color

G/BK

BN/BK

S/BK

BL/Y

O/Y

GN/Y
BN/Y

S/Y

BL/V

O/V

GN/V

BN/V

1
2
3
4
5
6
7
8
9

10
11
12

BL/W

O/W
G/W

BN/W

S/W

BL/R

O/R
G/R

BN/R

S/R

BL/BK

O/BK

Pins

Color

LED 13

LED 14

LED 15

LED 16

LED 17

LED 18

LED 19

LED 20

LED 21

LED 22

LED 23

LED 24

38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24

BK/G
G/BK

BK/BN
BN/BK

BK/S
S/BK

Y/BL
BL/Y

Y/O
O/Y

Y/GN
GN/Y
Y/BN
BN/Y

Y/S
S/Y

V/BL
BL/V

V/O
O/V

V/GN
GN/V
V/BN

BN/V

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

26

1

27

2

28

3

29

4

30

5

31

6

32

7

33

8

34

9

35
10
36
11
37
12

W/BL
BL/W

W/O
O/W
W/G
G/W

W/BN
BN/W

W/S
S/W

R/BL
BL/R

R/O
O/R
R/G
G/R

R/BN
BN/R

R/S
S/R

BK/BL
BL/BK

BK/O
O/BK

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

LED 1

LED 2

LED 3

LED 4

LED 5

LED 6

LED 7

LED 8

LED 9

LED 10

LED 11

LED 12

Polarity

Pins

Color

Black

Yellow

Control Line

Unused PABX
Trunk Input or

Analog station

Control Phone

Programming

.75”

1.00”

LM-2

 (Fax Back Document 660)

1000 foot

maximum run

using 26 AWG wire

Note:  Electronic or digital telephones usually require
a separate dedicated pair for operation of the message
waiting lamps.  When a dedicated pair is used, the
MLC-24 can provide low voltage for direct operation of
LED indicators, such as the LM-2.

Optional LM-24D

or

Optional LM-12W

(Fax Back Document 665)

(Fax Back Document 670)

or

C.O. Line

Summary of Contents for MLC-24

Page 1: ...em VIKING Technical Practice Telecommunication Peripheral Products MLC 24 Message Waiting Lamp Controller March 2 1998 Features Applications Sales 715 386 8861 Made in the U S A Power 120V AC 13 8V AC 1 25A UL listed adapter provided Dimensions 8 25mm x 160mm x 44mm 8 25 x 6 25 x 1 75 Shipping Weight 1 36 kg 3 lbs Environmental 0 C to 32 C 32 F to 90 F with 5 to 95 non condensing humidity Connecti...

Page 2: ...K NEON LED POWER 1 2 3 4 T1 R1 T2 R2 T3 R3 T4 R4 T5 R5 T6 R6 T7 R7 T8 R8 T9 R9 T10 R10 T11 R11 T12 R12 26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 W BL BL W W O O W W G G W W BN BN W W S S W R BL BL R R O O R R G G R R BN BN R R S S R BK BL BL BK BK O O BK T13 R13 T14 R14 T15 R15 T16 R16 T17 R17 T18 R18 T19 R19 T20 R20 T21 R21 T22 R22 T23 R23 T24 R24 38 13 39 14 40 15 41 16 42 1...

Page 3: ...nd 4 can be used to set message waiting light parameters and operational modes 13 14 15 16 17 18 19 20 21 22 23 24 Pins Color G BK BN BK S BK BL Y O Y GN Y BN Y S Y BL V O V GN V BN V 1 2 3 4 5 6 7 8 9 10 11 12 BL W O W G W BN W S W BL R O R G R BN R S R BL BK O BK Pins Color LED 13 LED 14 LED 15 LED 16 LED 17 LED 18 LED 19 LED 20 LED 21 LED 22 LED 23 LED 24 38 13 39 14 40 15 41 16 42 17 43 18 44 ...

Page 4: ...ust first dial the station extension number connected to the MLC 24 s control line The MLC 24 will answer with a steady tone The command codes can then be entered as shown in the table to the right Signaling the MLC 24 1 to turn lamp OFF at station xy 2 to turn lamp ON at station xy 3 to flash a lamp at station xy 4 to fast flash a lamp at station xy 5 to turn all lamps OFF Enter Digits 1 xy 2 xy ...