Viking Magni 2500 User Manual Download Page 1

 

 

VIKING 

Magni 2500

Návod na použití (CZ)

Summary of Contents for Magni 2500

Page 1: ...VIKING Magni 2500 N vod na pou it CZ...

Page 2: ...jen produktu VIKING MAGNI 2500 EB200 Nab jen ostatn ch za zen produktem VIKING MAGNI 2500 EB200 P klady elektrick ho za en Odhad provozn doby Technick speci kace Pokyny pro skladov n a dr bu Prohl en...

Page 3: ...zvratn mu po kozen za ze n 6 Neumis ujte v robek do bl zkos zdroj tepla jako jsou elektrick kamna lampy otev en ohni t krby atd 7 Produkt MAGNI 2500 nen povoleno p epravovat leteck mi linkami proto e...

Page 4: ...vstupn port 8 Vstupn port nab jec ho adapt ru 9 2 x Bezdr tov nab jen 15W 10 Dotykov interak n LCD displej 11 Tla tko nap jen ON OFF 12 4 x AC v stup Obsah balen 01 02 03 04 05 06 07 08 09 10 11 12 A...

Page 5: ...e nastaven 3 Podporujte sporu energie po ak vaci re im Super ECO u et te v ce ne 30 energie 4 Podpora prohl en informac o poruch ch historie informac o poru e verze so ware atd Tip Dotykov LCD displej...

Page 6: ...30V 50Hz DC vstupn zdroj PV sol rn Re im ECO NE Jazyk angli na a Tla tko Domovsk str nka b Tla tko Nastaven c Datov tla tko Informace d Tla tko Poruchy e Tla tko zobrazen PV nab jen automobilu f Tla t...

Page 7: ...gs 3 Pro nastaven data a asu klikn te na ka dou asovou hodnotu zvl zvl na m s c den rok hodinu minutu sekundu a na seln ku je nastavte 4 Po nastaven data a asu klikn te na tla tko OK v dku Time se ngs...

Page 8: ...nance m ete zobrazit provozn informace BMS Kliknu m na tla tko Fault Alarm History m ete zobrazit v echny dostupn informace o poruch ch gener toru Zde budou zaznamen ny v echny chybov k dy Poruchy lze...

Page 9: ...moc sol rn ch panel je 12A 3 Z cigaretov z suvky v aut S skn te tla tko nap jen a p ipojte jej k cigaretov z suvce v aut prost ednictv m nab jec ho kabelu Na hlavn str nce na displeji klikn te na tla...

Page 10: ...aretov v stup v stup USB a USB C Pokud chcete v stupy stejnosm rn ho nap vypnout op t zm kn te na displeji DC ON OFF m potvrd te vypnu DC okruhu 2 Nab jen pomoc st dav ho AC nap Nejprve s skn te hlavn...

Page 11: ...toma cky vypne aby nedo lo k po kozen gener toru V t inou doch z k ak vaci nadproudov ochrany kdy pom r pi kov hodnoty jmenovit ho proudu p esahuje 3 1 V t chto p padech doporu ujeme vybrat jin elektr...

Page 12: ...USB C Bezdr tov nab jen Jmenovit v stupn v kon N zk jmenovit nap Vysok jmenovit nap THD innost Max p e en Ochrana pro zkratu Ochrana pro p eh Hlu nost Jmenovit nap Jmenovit proud S la p e en Ochrana p...

Page 13: ...vysok teplot baterie p i vyb jen obnoven vyb jen nab jen obnoven nab jen Ochrana nab jen p i n zk teplot Rozm ry Hmotnost Pracovn teplota Skladovac teplota Pracovn vlhkost 65oC 149oF max 55oC 131oF ma...

Page 14: ...t k osobn bezpe nost jako jsou za zen pro atomovou energii leteck a kosmick za zen zdravotnick prost edky na kter ch z vis ivot pacienta nebo za zen kter mus b t vysoce spolehliv Pokud i p es toto var...

Page 15: ...ost ed Nepou vejte a neuchov v te v pra n m a mokr m prost ed P ed ka d m pou i m zkontrolujte p stroj Nepou vejte p stroj pokud je po kozen nebo jakkoliv jinak rozbit Nepou vejte p stroj pokud je nap...

Page 16: ...ek jmenovit ho v konu kter snadno vyvol p e en st dav m proudem Lze propojit dva gener tory MAGNI 2500 a pou vat je sou asn pro zv en v konu Ne Mohu pou t sol rn panely t e ch stran M ete pou t jak ko...

Page 17: ...VIKING Magni 2500 User manual EN...

Page 18: ...How to use the touch screen Charging the product Discharging the product Examples of loads Es ma on of opera ng me Technical speci ca ons Storage and maintenance instruc ons Declara on Common faults a...

Page 19: ...when using this product near children 6 Please con rm the rated speci ca on of your load and do not use it beyond the speci ca on 7 Do not place the product near heat sources such as electric furnace...

Page 20: ...ar input port 8 Charging Adapter Input Port 9 2 x Wireless charging 15W 10 Touch Interac on LCD Display 11 ON OFF power bu on 12 4 x AC output Contents of the pack 01 02 03 04 05 06 07 08 09 10 11 12...

Page 21: ...upport users to view fault informa on historical fault informa on so ware version independently 5 The opera on steps of touch screen Warm p The touchable LCD screen is a resistance screen we recommend...

Page 22: ...frequency and other parameters for the rst me The default AC output 230V 50Hz DC Input Source PV solar ECO Mode NO Press Next bu on to enter language and date se ng as below Figure 3 Language Japanese...

Page 23: ...3 To set the date and me click each me value separately month day year hour minute second separately and set them on the dial 4 A er se ng the date and me click the OK bu on in the Time se ngs line to...

Page 24: ...key in the main interface Click the Fault History Alarm bu on you can view all the fault informa on generated by the machine All the fault codes recorded here According to the fault codes return to t...

Page 25: ...atus Max current of the solar is 12A 3 Charging mode 3 From the car lighter port Press the power bu on and connect it to the cigare e lighter port through the car charging cable Enter the se ng interf...

Page 26: ...OFF bu on and con rm Turn o these output and also click the DC on o bu on and con rm 2 Turn on AC output rst press the power bu on then enter the main interface through the touch screen click the AC...

Page 27: ...select the electrical appliances with lower power rate 3 When the output is overload over current or short circuit the product will turn o the corresponding output and then it will automa cally start...

Page 28: ...Rated current 25A Overload power 330W load 2S Short circuit protec on yes DC12V 10A output Rated voltage 12V Rated current 10A Overload power 120W 2s Short circuit protec on yes DC12V 3A output Rated...

Page 29: ...func on please unplug the PV charging head a er full charge 2 It supports charging while discharging and does not support UPS func on Ba ery Pack Rated capacity 2000Wh 40Ah Voltage 41 5V 58 4V Short...

Page 30: ...t on the above men oned equipment or machine we will not be responsible for personal accident re accident or wrong ac on of the machine and equipment caused by the failure of this product This device...

Page 31: ...n dusty and wet environment Check the device before each use Do not use the device if damaged or otherwise broken Do not use the device if the power cord is damaged or broken STORE OUT OF CHILDREN Do...

Page 32: ...rty solar panels You can use any solar panels available as long as they have MC4 connectors and when wired together the voltage is between 35V to 150V and no more than 700W How do I know if my applian...

Reviews: