Viking Le Maitre Freezing Pro Operator'S Manual Download Page 6

RECOMMENDED FLUIDS

LOW SMOKE FLUID

The "Molecular Fluid" was originally designed for use in the LSX and LSG, however, many other applications
were found very quickly. It is a clean, white, thick fog, practically odourless and dissipates as it begins to warm.

MAINTENANCE

The  only  interior  maintenance  required  for  the  Freezefog  is  that  the  hose  end  of  the  Liquid  Carbon  Dioxide
supply line be kept clean and free of debris. When not in use keep the supply line hose end capped or covered
to prevent debris from entering and insects from nesting inside the line.

EXTERIOR

The exterior of the Freezefog requires only mild soap and water to clean.

Warning:

Le Maitre Ltd considers all its products to be safe for use in the application it was intended. Le Maitre Ltd takes
no responsibility for misuse or incorrect use. Always refer to equipment owner’s manual for proper use.

SAFETY PRECAUTIONS

1. Ensure that operation of the machine is supervised by suitably trained and authorized personnel.

2. Do not modify the machine or use a machine which has been damaged in any way.

3. Allow sufficient air circulation around the machine at all times.

4. Protect the Gforce3 from direct weather effects and wet locations.

5. Only use fluids recommended by the Manufacturer.

6. Do not continue to produce Fog output in an enclosed area when visibility is reduced below 50cm.

7. Avoid direct Fog output continuously at persons, structure or objects within close proximity of the discharge
nozzle.

8. Ensure that adequate exhausting arrangements are available in the event of an emergency.

9. Do not place hands, or exposed skin within the first 50cm of the discharge nozzle at any time during fog
production.

Please return this manual with your hire or a charge of £5 will be made

Page 6

If in doubt, please call Viking Stage Lighting:
Office Hours (01603) 401982
Out of Hours (07894) 758256 or (07770) 422112
If no Mobile Reception then email [email protected] - monitored 24 hours a day

Summary of Contents for Le Maitre Freezing Pro

Page 1: ...fog consumes approximately 3 5 kilos of liquid carbon dioxide per minute of operation at 350 PSI 25bar At the typical variflow setting of 20 the Gforce3 will consume approximately 4 litres of fluid per hour constant The system can be controlled via the standard digital remote control or DMX The DMX Interface allows the Freezefog Gforce3 to be controlled on separate DMX channels Standard equipment ...

Page 2: ... allows the liquid CO2 to purge the supply hose of CO2 gases ensuring only liquid is available for optimum cooling The recommended formula for calculating delay time is 1 sec for every three feet of supply hose Please refer to the Gforce 3 Instruction manual for use with this machine 6 Adjust the remote flow rate to desired fog output level It is recommended to start at 16 and adjust accordingly T...

Page 3: ...vel indicator located on the top of the Liquid CO2 Tank These valves handles should be labeled as Gas Vent Liquid and Pressure Builder We will cover each of these below Gas Vent This is used if a CO2 gas supply is utilized As we only use the liquid supply to operate the Freezefog this valve is not opened Liquid This is the source of our liquid supply of CO2 The Freezefog CO2 supply hose is threade...

Page 4: ...og may condensate on the inside of the G300 damaging the electronic components See further in this manual for suggested solutions and ducting examples Technical Tip If dividing the output to more than one location while ducting make sure the sum of all cross sectional areas of the final duct sizes is equivalent or greater than the cross sectional area of the Freezefog 10 outlet Doing this will pre...

Page 5: ...ne from the Freezefog turn on the G300 and place your hand in the fog stream 24 away from the front of the machine Your hand should be dry You will feel a slight warming but do not confuse this for moisture If the machine is not performing properly your hand will be very wet The G300 should be serviced to rectify the problem 8 Too much fog is being pushed through the Freezefog On the High Pressure...

Page 6: ...TIONS 1 Ensure that operation of the machine is supervised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow sufficient air circulation around the machine at all times 4 Protect the Gforce3 from direct weather effects and wet locations 5 Only use fluids recommended by the Manufacturer 6 Do not continue to produce Fog...

Reviews: