background image

Features

Tenant’s phone numbers: 001-002 (0-32 digits), 003-250 (0-16 digits) ................  

Tenant’s phone numbers and keyless entry codes ..............................................

Keyless entry code only (4 - 6 digits) ...................................................................

Master keyless entry code (4 - 6 digits) ................................................................

Maintenence personnel entry codes (4-6 digits) .................................................. 

Clear one phone number and/or keyless entry code ............................................

PABX line access number: 1-3 3 sec pause (factory disabled) ................

Relay activation time: 1/2-99 sec (00 = 1/2 sec, factory set to 5 sec) ...................

Relay activation code*: 1-2 digits (factory set to 36) ............................................  

Security code (factory set to 845464) ..................................................................

Maximum call time: 0-99 min (00 = disabled, factory set to 2 min) ......................

To exit programming ............................................................................................

Normal dialing speed (120ms on/off, factory setting) ...........................................

Fast dialing speed (50ms on/off) ..........................................................................

Apartment dialer mode (factory setting) ...............................................................

Multi-number dialer mode ....................................................................................

Ring thru mode OFF (factory setting) ...................................................................

Ring thru mode ON ..............................................................................................

To add a 4 second pause anywhere in the dialing string ......................................  

To add a 1 second pause anywhere in the dialing string ......................................

911/311 dialing enabled (factory setting) .............................................................

911/311 dialing disabled ......................................................................................

To add a 

,

at any point in the dialing string ..........................................................

To add a 

#

at any point in the dialing string ..........................................................

Clear all phone numbers and keyless entry codes from memory
and set all programming features back to factory settings ................................... 

phone number

phone  

#

,

+ entry code +

#

,

+ entry code

#

,

+ entry code

#

,

+ entry code

(no digits)

1-3 digits

2 digits

(00 - 99)

1-2 digits

(00 - 99)

6 digits

(0 - 9)

2 digits

(00 - 99)

(no digits)

,

1

,

2

,

3

,

4

,

5

,

6

,

7

,

8

,

9

,

0

,,
,

#

###

#001-250

#001-250

#001-250

#000

#251-255

#001-250

##2

##3

##4

##5

##6

##7

* Note: 

When a single digit relay activation code is programmed (0-9), the activation Touch Tone must be held for a minimum of

150 milliseconds.

Notes:

Each pause uses a single space in memory.  To clear a memory location, enter “

#

“ + the memory location without any pre-

ceeding digits. A 

valid

programming entry will be indicated by a double beep. An invalid entry will be indicated with three beeps.  

E. Programming Features Quick Reference

Memory

Location

Enter Digits

- then -

+

+

+

+

+

+

+

+

+

+

+

(

Caution:

Permanently erases ALL programming!)

F. Programmable Maximum Call Time

The 

K-1900-3

can be programmed to limit the call time on the entry phone.  The maximum call time is programmable from “

00

” (no

maximum call time) to “

99

” (99 minutes) and is factory set to “

02

” (2 minutes) (see 

Programming

, section 

D

).  When the call timer

is enabled (programmed to “

01-99

”), if a call exceeds the programmed time, both phones are provided with three beeps then dis-

connected, indicating the termination of the call. This limits unnecessary and lengthy conversations. When the call timer is disabled
(programmed to “

00

”), there is no limit to the length of calls from the entry phone.  Only a CPC disconnect signal from the telephone

line, or hanging up the entry phone will disconnect the call.  

G. Built-In Toll Restriction

The 

K-1900-3

features built-in toll restriction.  When the 

K-1900-3

is in the 

Apartment Dialer Mode

(factory setting), the unit will

disconnect when it detects any Touch Tone or pulse dialing generated by the entry phone, after speed dialing has been completed.
With the 

K-1900-3

in the 

Multi-Number Dialer Mode

, the unit will disconnect when it detects any flashes or pulse dialing generat-

ed by the phone after speed dialing has been completed.

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

When a visitor accesses the entry phone, simulated dial tone is heard.  After the visitor enters the appropriate one to three digit ten-
ant number (equal to the memory location in programming), the 

K-1900-3

dials the tenant’s phone number and bridges the phone

line to the entry phone.  If an unprogrammed tenant number is entered, a simulated fast busy signal will be heard on the entry phone.
When the tenant confirms the visitors identity, a one or two digit relay activation code may be entered from the tenant’s phone.  Two
beeps will indicate that a valid activation code has been entered.  A buzzing sound is then heard on the entry phone to indicate the
door strike has been activated.  If an incorrect relay activation code is entered, the unit will disconnect.  A simulated fast busy signal
will also be returned to the entry phone if the telephone line has become disconnected. A tenant may use their personal keyless entry
code to let themselves in by taking the entry phone off-hook and entering a “

#

” followed by their (4 - 6 digit) personal keyless entry

code. 

Note:

To avoid busy signals on the entry phone, call waiting is recommended on each tenant’s phone line.

A. Apartment Dialer Mode

(factory setting)

5

Summary of Contents for K-1700-3

Page 1: ...de Programmable master keyless entry code and five maintenance codes Programmable call timer Multi number dialer mode for Kiosks etc Ring thru mode for calling the entry phone Normally open and normally closed DPDT relay contacts for controlling door strikes magnetic locks gates etc Auxiliary relay input to trigger a timed relay activation for postal locks etc Touch tone and pulse dialing toll res...

Page 2: ...rning or late evenings It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These ...

Page 3: ...follows 1 Access programming as shown in section A 2 Enter your new security code followed by 5 3 To exit remote programming enter 7 or do not enter any touch tones for at least 20 seconds To exit local programming simply hang up the entry phone Note The security code must be six digits in length and MUST NOT contain a or If you have forgotten your security code see section A Local Programming Wit...

Page 4: ...one number and keyless entry code for that tenant may be cleared without affecting any other tenant s phone numbers or their key less entry codes Likewise maintenance keyless entry codes may be assigned temporarily and cleared when no longer needed Note The keyless entry codes should all be the same number of digits either 4 5 or 6 A keyless entry code may be programmed without a phone number Note...

Page 5: ... 00 no maximum call time to 99 99 minutes and is factory set to 02 2 minutes see Programming section D When the call timer is enabled programmed to 01 99 if a call exceeds the programmed time both phones are provided with three beeps then dis connected indicating the termination of the call This limits unnecessary and lengthy conversations When the call timer is disabled programmed to 00 there is ...

Page 6: ...ials the phone number programmed in that memory location then bridges the phone to the line The user is now free to dial any Touch Tone numbers required to steer through automated attendants etc If the user attempts to pulse dial or flash the line for fresh dial tone to make a toll call the K 1900 3 will restrict the call by switch ing the phone back to artificial talk battery with a simulated bus...

Page 7: ...069 070 071 072 073 074 075 Please use these charts to record the numbers programmed into the K 1900 3 use pencil Security Code Relay Activation Code Apt Tenant s Phone Memory Location 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129...

Page 8: ...204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 Apt Tenant s Phone Memory Location 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 Memory Location 000 251 252 253 254 255 Description Master Maintenance Personnel Maintenance Personnel Maintenance Personnel Maintenance Personnel Maintenance Personnel Addition...

Reviews: