Viking K-1270-IP Series Product Manual Download Page 22

22

Switch

SIP VoIP PBX, 

SIP Cloud based 
Service Provider

or

PC with SIP 

Server Software

Internet

PoE

Switch

LED 8

LED 7

LED 6

LED 4

LED 3

LED 2

LED 1

LED 5

LED 9

1

2

3

on

4

1 2 3 4

VIKING

ELECTRONICS

HUDSON, WI 54016

NETWORK ENABLED

RELAY CONTROLLER

MODEL RC-4A

©

VIKING

1

IN1  C

IN2 IN3  C

IN4

2

3

4

5

6

POWER 12V DC

RELAY 1

RELAY 2

RELAY 3

RELAY 4

1

2

3

4

5

7

8

9 10 11 12

STATUS

LED

6

NETWORK

LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE

12V DC Adapter

(included)

Sensor

Examples:

Door Sensor

Gate Sensor

Door Sensor

Door Sensor

N.O.

COM. 

Connect to Doorstrike,

Mag Lock, Gate Controller, etc.

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 
Magnetic Lock

120V AC

Door / Gate Examples:

Door near Entry Phone 1

N.O. 

COM. 

2 Gel-Filled Butt

Connectors 

(included)

(Power typically not

required for gate controllers)

Gate Controller

K-1270-IP

Entry Phone 1

K-1270-IP

Entry Phone 2

K-1270-IP

Entry Phone 3

K-1270-IP

Entry Phone 4

 Relay 2 Output Contacts 

(5A@30VDC / 250VAC max)

Connect to Gate Controller, etc.

Gate near Entry Phone 2

N.O.

COM. 

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 
Magnetic Lock

120V AC

Door near Entry Phone 3

N.O.

COM. 

 Relay 4 Output Contacts 

(5A@30VDC / 

250VAC max) 

Connect to Doorstrike, 

Mag Lock, Gate Controller, etc.

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 

Magnetic Lock

120V AC

Door near Entry Phone 4

1

IN1  C IN2 IN3  C IN4

2 3 4 5 6

 Relay 1 Output Contacts 

(5A@30VDC / 250VAC max)

Connect to Doorstrike,

Mag Lock, Gate Controller, etc.

 Relay 3 Output Contacts 

(5A@30VDC / 250VAC max)

Optional Secure Remote Relay Control Using a Viking Model RC-4A

The front panel of the 

K-1270-IP

 is mounted using security Torx screws to help prevent intruders from removing the panel 

and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model 

RC-4A

 remote relay controller can be used. The relay controller is mounted securely inside the building and connected to 

the same LAN as the 

K-1270-IP

.  The on board door strike relays would not be used in this case as the 

K-1270-IP

 will send 

an encrypted message to the 

RC-4A

 to activate its relays which control the door strikes/gates. For more information, see 

DOD# 582 at www.VikingElectronics.com. 
 
Up to 4 

K-1270-IP’s

 can communicate with one 

RC-4A

 allowing you to securely control four entrances. 

 
When using an 

RC-4A

 for remote relay control the 

K-1270-IP’s

 relays should be set to “External” in the PC programming. 

 

Note: 

 If the 

K-1270-IP

 loses communications with the 

RC-4A

, the LED on the front panel of the 

K-1270-IP

 will flash 3 times 

every 2 seconds indicating the communication error. If this error occurs, make sure the 

RC-4A

 is powered, has a network 

connection and has the correct IP address and security code of the 

K-1270-IP

 displaying errors.

Summary of Contents for K-1270-IP Series

Page 1: ...single push auto dialing of a tenant s phone number or business extension When the K 1270 IP phone is connected to an apartment or business tenant a built in contact closure may be activated to contr...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...s a signaling communications protocol widely used for controlling multimedia communication sessions such as voice and video calls over Internet Protocol IP networks The protocol defines the messages t...

Page 4: ...Output Viking Model PRX 3 or LRR 4 See DOD 228 OR 226 Optional Long Range RFID Receiver Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire wit...

Page 5: ...flush mount unit using the included rough in box or as a surface mount unit using an optional VE 5x10 or VE 5x10 SS The rough in box uses the inner set of four holes on the face plate while the VE 5x1...

Page 6: ...l Viking model RC 4A Secure Remote Relay Controller see page 6 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network PC Programming IBM compatible personal computer...

Page 7: ...trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network wi...

Page 8: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Page 9: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Page 10: ...de must be set to Door Strike 22 17 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 17 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit...

Page 11: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1270 IP Series Phone being programmed When registered to a...

Page 12: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1270 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Page 13: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Page 14: ...lity to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call the K 1...

Page 15: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Page 16: ...ng Disabled The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated After the called party enters the correct relay activation command the...

Page 17: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Page 18: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1270 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Page 19: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Page 20: ...one of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Rela...

Page 21: ...rogrammed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card within 6 inch...

Page 22: ...netic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Page 23: ...backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and scre...

Page 24: ...age across the network to activate one of the relays on the other unit Two levels of user access permit selected users to have full operational and programming rights while others have operational con...

Page 25: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Reviews: