background image

C

Co

on

nttrro

oll  C

Co

on

nffiirrm

ma

attiio

on

n//C

Co

om

mm

me

en

ntt

S

Sh

ho

ow

w  R

Ro

oo

om

m  M

Mo

od

de

e  w

wiillll  d

diissa

ab

blle

e  tth

he

e  rre

effrriig

ge

erra

atto

orr  ssyysstte

em

m  a

an

nd

d  ffa

an

nss  w

wh

hiille

e  a

allllo

ow

wiin

ng

g  tth

he

e  iin

ntte

errn

na

all  lliig

gh

httss,,  d

diissp

plla

ayy  a

an

nd

d  u

usse

err  iin

ntte

errffa

acce

e

p

pa

an

ne

ell   tto

o   ffu

un

nccttiio

on

n..   L

Liig

gh

httss   w

wiillll   ttiim

me

e   o

ou

utt   a

afftte

err   1

15

5--m

miin

nu

utte

ess   o

off   cco

on

nttiin

nu

uo

ou

uss   o

on

n--ttiim

me

e   w

wh

hiille

e   iin

n   S

Sh

ho

ow

w   R

Ro

oo

om

m   M

Mo

od

de

e   a

ass   a

a   ssa

affe

ettyy

ffe

ea

attu

urre

e..  T

Th

he

e  1

15

5--m

miin

nu

utte

e  lliig

gh

htt--o

on

n  ttiim

me

e  cca

an

n  b

be

e  rre

ea

accttiivva

atte

ed

d  b

byy  ccllo

ossiin

ng

g  a

an

nd

d  o

op

pe

en

niin

ng

g  tth

he

e  d

do

oo

orr  o

orr  b

byy  p

prre

essssiin

ng

g  tth

he

e  kke

eyyp

pa

ad

d..

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

18

19

ON 

OFF

SET

WARMER

COLDER

˚̊

F/C

PRESS AND HOLD

POWER FAILURE - Flashing Amber

HIGH/LOW TEMP - Red

PRESS ON/OFF - Reset

ALARMS OFF - Steady Amber

TruProtect System

38˚

F

Fu

un

nccttiio

on

n

F

Fu

un

nccttiio

on

n  A

Acccce

essss

S

Sh

ho

ow

w  R

Ro

oo

om

m  M

Mo

od

de

e

S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss

“E

En

ntte

err”

”  a

an

nd

d  “

“E

Exxiitt”

”  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  m

mo

od

de

e  b

byy  p

prre

essssiin

ng

g  a

an

nd

d  h

ho

olld

diin

ng

g  tth

he

e

kke

eyyp

pa

ad

d

w

wh

hiille

e  p

prre

essssiin

ng

g  tth

he

e

kke

eyyp

pa

ad

d  4

4--ttiim

me

ess  w

wiitth

hiin

n  5

5--sse

ecco

on

nd

dss..  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  m

mo

od

de

e

a

allsso

o  w

wiillll  a

au

utto

om

ma

attiicca

allllyy  e

exxiitt  a

afftte

err  5

5--m

miin

nu

utte

ess  o

off  n

no

o  kke

eyyp

pa

ad

d  e

en

nttrryy..

D

Diissp

plla

ayy  E

Errrro

orr  C

Co

od

de

e  R

Re

effe

erre

en

ncce

e::

T

Th

he

e  m

miiccrro

op

prro

occe

esssso

orr  iin

n  tth

he

e  cco

on

nttrro

oll  cco

on

nttiin

nu

ua

allllyy  m

mo

on

niitto

orrss  ccrriittiicca

all  rre

effrriig

ge

erra

attiio

on

n  ssyysstte

em

m

cco

om

mp

po

on

ne

en

nttss  ffo

orr  p

prro

op

pe

err  o

op

pe

erra

attiio

on

n..  IIff  cco

om

mp

po

on

ne

en

ntt  p

pa

arra

am

me

ette

errss  e

exxcce

ee

ed

d  n

no

orrm

ma

all  o

op

pe

erra

attiin

ng

g

ssp

pe

ecciiffiicca

attiio

on

nss,,  tth

he

e  d

diissp

plla

ayy  w

wiillll  a

au

utto

om

ma

attiicca

allllyy  fflla

assh

h  tth

he

e  rre

essp

pe

eccttiivve

e  e

errrro

orr  cco

od

de

e  a

ass  ffo

ollllo

ow

wss::

P

Plle

ea

asse

e  cca

allll  a

a  q

qu

ua

alliiffiie

ed

d  sse

errvviicce

e  tte

ecch

hn

niicciia

an

n  iiff  a

an

nyy  o

off  tth

he

esse

e  cco

od

de

ess  a

arre

e  d

diissp

plla

ayye

ed

d..

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

TruProtect

“Advanced” Function “Quick” Reference

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

E

En

na

ab

blle

e  tth

he

e  S

Sh

ho

ow

w  R

Ro

oo

om

m  M

Mo

od

de

e  b

byy  p

prre

essssiin

ng

g  a

an

nd

d  h

ho

olld

diin

ng

g  tth

he

e

kke

eyyp

pa

ad

d  w

wh

hiille

e

p

pe

errffo

orrm

miin

ng

g  a

a  “

“P

Po

ow

we

err  O

On

n  R

Re

esse

ett”

”,,  ((P

PO

OR

R)),,  ii..e

e..  --  d

diisscco

on

nn

ne

ecctt  a

an

nd

d  rre

ecco

on

nn

ne

ecctt  tth

he

e  p

po

ow

we

err

ssu

up

pp

pllyy  tto

o  u

un

niitt..  E

Exxiitt  S

Sh

ho

ow

w  R

Ro

oo

om

m  M

Mo

od

de

e  b

byy  iin

niittiia

attiin

ng

g  a

a  P

PO

OR

R  o

on

nllyy..  

E1

E2

E3

E4

Compressor fault, (high/low amps).

Condenser fan motor fault, (high/low amps).

Evaporator thermistor “sensor B” fault, (out-of-range).

Display thermistor “sensor A” fault, (out-of-range).

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  M

Mo

od

de

e  e

en

na

ab

blle

ess  sse

errvviicce

e  tte

ecch

hn

niicciia

an

nss  tto

o  iid

de

en

nttiiffyy  tth

he

e  ffiirrm

mw

wa

arre

e  a

an

nd

d  sso

offttw

wa

arre

e  vve

errssiio

on

nss,,  tte

esstt  sstta

attu

uss  o

off

“m

mo

od

de

ell  ssp

pe

ecciiffiicc”

”  ssyysstte

em

m  cco

om

mp

po

on

ne

en

nttss  a

an

nd

d  sse

en

nsso

orrss  a

an

nd

d  cch

ha

an

ng

ge

e  sstta

atte

e  o

off  cco

om

mp

po

on

ne

en

nttss  w

wh

he

erre

e  a

ap

pp

plliicca

ab

blle

e,,  ((ii..e

e..  --  cco

om

mp

prre

esssso

orr

o

on

n//o

offff,,  e

ettcc......))..  W

Wh

hiille

e  iin

n  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  M

Mo

od

de

e,,  tte

essttss  a

arre

e  iin

nccrre

em

me

en

ntte

ed

d  b

byy  p

prre

essssiin

ng

g  tth

he

e              kke

eyyp

pa

ad

d  a

an

nd

d  ssp

pe

ecciiffiicc

cco

om

mp

po

on

ne

en

ntt  sstta

atte

e  cca

an

n  b

be

e  cch

ha

an

ng

ge

ed

d  tto

o  “

“o

on

n”

”  a

an

nd

d  “

“o

offff”

”  b

byy  p

prre

essssiin

ng

g  tth

he

e

a

an

nd

d

kke

eyyp

pa

ad

dss  rre

essp

pe

eccttiivve

ellyy..  T

Th

he

e

ffo

ollllo

ow

wiin

ng

g  cco

om

mp

po

on

ne

en

ntt  tte

essttss  a

arre

e  a

avva

aiilla

ab

blle

e::

Test #

Component Description

OK

Off/Open

On/Shorted

0

Temp Sensor A

1

Temp Sensor B

2

Compressor

n/a

3

Interior/Ice Maker Fan

n/a

4

Reverse Gas Solenoid

n/a

5

Condenser Fan

n/a

6

Mullion Heater

n/a

7

Door A Sense

n/a

8

Door B Sense

n/a

9

Door C Sense

n/a

Available Status Indicators

0 -

1 -

0 0

10

20

30

40

50

60

70

80

90

0 1

11

21

31

41

51

61

71

81

91

Note: Must use magnet to change state of Door C Sense.

ON 

OFF

SET

PRESS AND HOLD

38˚

magnet sense area

SERVICE DIAGNOSTICS

Summary of Contents for Freestanding Refrigerated Drawer

Page 1: ...tion 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKNG1 845 4641 or visit the Viking Web Site at vikingrange com Viking Use Installation Guide Undercounter Freestanding Refrigerated Drawer ...

Page 2: ...one unable to operate it properly used only for its intended purpose properly maintained SAVE THESE INSTRUCTIONS SUFFOCATION HAZARD Remove doors from your old refrigerated drawer Failure to do so can result in child entrapment which can cause death or brain damage IMPORTANT Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerated drawers are still dangerous ev...

Page 3: ...c D Da at ta a 115 VAC 60 Hz Maximum amps 3 3 Approximate Shipping Weight 180 lbs 81 8 kg 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 23 7 8 60 6 cm Front View Side View 26 7 8 68 3 cm 24 3 8 61 9 cm 22 55 9 cm 46 7 8 119 0 cm 48 3 4 123 8 cm ...

Page 4: ...D Da at ta a 115 VAC 60 Hz Maximum amps 3 3 Approximate shipping weight 180 lbs 81 8 kg 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 23 7 8 60 6 cm Front View Side View 26 7 8 68 3 cm 24 3 8 61 9 cm 22 55 9 cm 46 1 2 118 1 cm 48 3 4 123 8 cm ...

Page 5: ...e is attached at the back of each cabinet Please see installation instructions supplied with the anti tip device WARNING LEG LEVELER INSTALLATION R Re ea ad d B Be ef fo or re e I In ns st ta al ll li in ng g L Le eg g L Le ev ve el le er rs s 1 Four leveling legs are pre installed in the base of the unit at the factory 2 The unit should be leveled from front to back and side to side If floor cond...

Page 6: ...ard and then down releasing the drawer from the cabinet slide Figure 2 Repeat this on the opposite side of the drawer Lift the drawer up from the slides at 90o to fully remove the drawer from the cabinet Figure 3 2 Remove drawer fronts Do this by removing the 8 phillips screws and washers securing the drawer front to the drawer body Mark lightly with an erasable marker the position of the stainles...

Page 7: ...s cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel scratches are almost impossible to remove ELECTRICAL CONNECTION E El le ec ct tr ri ic ca al l R Re eq qu ui ir re em me en nt ts s A 115 v...

Page 8: ... F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA F Fu un nc ct ti io on n F Fu un nc ct ti io on n A Ac cc ce es ss s T Tu ur rn n U Un ni...

Page 9: ...anel Installation on page 6 3 Remove old lights Use 2 small thin bladed screwdrivers or putty knives to press in the locking tabs on the lens housing Figures 4 and 5 With the locking tabs depressed pull downward Figure 6 the light housing will pop free Disconnect the wire lead by pulling straight out from the connector Connect wire lead to new light and re install into metal housing The light will...

Page 10: ...e e a as s f fo ol ll lo ow ws s P Pl le ea as se e c ca al ll l a a q qu ua al li if fi ie ed d s se er rv vi ic ce e t te ec ch hn ni ic ci ia an n i if f a an ny y o of f t th he es se e c co od de es s a ar re e d di is sp pl la ay ye ed d ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C 55 F LIGHT 13 C 38 F 4 C SA TruProtect Advanced Function Quick Referen...

Page 11: ...If the product or one of its component parts contains a defect or malfunction during the warranty period after a reasonable number of attempts by the warrantor to remedy the defects or malfunctions the owner is entitled to either a refund or replacement of the product or its component part or parts Replacement of a component part includes its free installation Warrantor s liability on any claim of...

Page 12: ...son alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage wh...

Reviews: