Remove access door.

Electrical Connection (3-wire)

Note:

If you have a 4-wire connection, see following section for

4-wire connection instructions.

Use a 3-wire power supply cord kit rated for
40 amps – 125/250 volts with closed loop
terminals and marked for use with ranges.

Do not use a GFI circuit. Where local codes
do not permit grounding through neutral,
use a 4-wire power supply cord. The cord or
conduit must be secured to the range with
the strain relief bracket.

The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.

2

Remove supply cord strain relief

bracket and three supply cord mounting screws

on terminal block.

WARNING

Electrical shock hazard.

To avoid risk or electrical

shock, personal injury or death;

grounding product to the frame

of the unit may or may not be permitted

through your local codes. If ground to the

frame is not permitted then a 4 conductor

power cord must be used.

WARNING

Electrical shock hazard.

To avoid risk of electrical shock,

personal injury or death; verify

your appliance has been

properly grounded in accordance with

local codes or in absence of codes, with

the National Electrical Code (NEC).

ANSI/NFPA 70-latest edition.

1

1

1

2

3

2

Legs are packed in styrofoam top pack.

Note:

Legs should be installed near to where

appliance is to be used, as they are

not secure for long transit.

Note:

It is strongly recommended

that a pallet or lift jack be used rather than tilting.

Raise unit about a foot. Unscrew temporary legs from

couplings on all four corners.

4

Lower range gently to keep any undue strain from

legs and internal mounting hardware.

3

Screw legs into couplings on all

four corners.

Leg Installation

3

Feed supply cord up through hole in bottom

of range back.

Summary of Contents for F20533 EN

Page 1: ...reet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20533A EN 120908J Viking Installation Guide Profe...

Page 2: ...__________________________26 Performance Checklist ______________________________________________________________________26 Service Registration _______________________________________________________...

Page 3: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qua...

Page 4: ...im Dual Fuel 30 36 48 and 60 W Ranges 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 20 3 cm min to 37 94 cm max 24 5 16 61 8 cm 28 1 16 71 2...

Page 5: ...add 1 2 5 cm To top of backguard add 8 20 3 cm To top of high shelf add 23 1 2 59 7 cm Gas Requirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts st...

Page 6: ...of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the r...

Page 7: ...this manual before work begins Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since s...

Page 8: ...ti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film r...

Page 9: ...h grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical...

Page 10: ...of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition Use a 4 wire power supply cord kit rated for 40 amps 125 250 volts with closed loop terminals and marked for use with ranges...

Page 11: ...side and front to back Side trim of the high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 Lift unit and prop on wood blocks 4 Feed supply cord...

Page 12: ...alified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING Tipping hazard To reduce the risk of property damage or personal injury install ant...

Page 13: ...must be pointing towards back of range 4 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not...

Page 14: ...See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake element on full power center and outside broil elements at partial power h Convectio...

Page 15: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Notes _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Page 16: ...31 30...

Reviews: