GAS
Fixed piping installations

• Check with local gas utility

company or with local codes
for instructions on installing gas
supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.

• An installer-supplied gas shut-

off valve must be installed in an
easily accessible location. All
installer-supplied parts must
conform to local codes.

• Must be isolated from the gas

supply piping system by closing
its individual manual shut-off
valve during any pressure
testing of that system at test
pressures equal to or less than
1/2 psi (3.5 kPa).

Natural gas models

• Water column pressure

o Operating pressure—4.0”

WCP

o Supply pressure of 6” – 14”

WCP

o If incoming pressure exceeds

14” WCP, a step-down
regulator is required.

• Accepts standard residential

1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.

o If using a Viking GSH12

flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.

LP/propane models

• Water column pressure

o Operating pressure—10”

WCP

o Supply pressure of 11” – 14”

WCP (for fixed piping
installations)

o If incoming pressure exceeds

14” WCP, a step-down
regulator is required.

• Accepts standard residential

1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.

LP/propane tank installations

• Water column pressure

o Operating pressure—10”

WCP

• Includes high-capacity

hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection

device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.

o The cylinder must be

provided with a shut-off valve
terminating in an LP/propane

gas supply cylinder valve
outlet specified.

o The cylinder supply system

must be arranged for vapor
withdrawal and provided with
a listed OPD (overfilling
prevention device).

ELECTRICAL

T-Series models
o 9-volt DC battery for

electronic ignition (not
included?)

o 2’ (61.0 cm) power cord

supply cord with 3-prong
grounded plug attached to
rotisserie

120 VAC/60 Hz

o Rotisserie motor max. amp

usage—6.0

E-Series models
o 3’ (91.4 cm) power cord

supply cord with 3-prong
grounded plug attached to
grill

120 VAC/60 Hz

o Grill max. amp usage—3.0
o 2’ (61.0 cm) power cord

supply cord with 3-prong
grounded plug attached to
rotisserie

120 VAC/60 Hz

o Rotisserie motor max. amp

usage—6.0

PLUMBING

• Not applicable

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

R E L E A S E D 0 5 / 1 2 / 0 8

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

OUTDOOR—COOKING

53”W. Ultra-Premium T-Series/E-Series Gas Grill

UTILITY

REQUIREMENTS

Installation Requirements

VGBQ530-4RT/E

VGBQ532-3RT/E

VGIQ530-4RT/E

VGIQ532-3RT/E

Burner rating

Standard SS grill burners (each)

25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP

Smoker burner (split standard)

12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP

GourmetGlo™ rotisserie burner

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

Side grill burners (each)

15,000 BTU (4.4 kW) Nat./

15,000 BTU (4.4 kW) Nat./

13,500 BTU (4.0 kW) LP

13,500 BTU (4.0 kW) LP

TruSear infrared burner

30,000 BTU (8.8 kW) Nat./LP

30,000 BTU (8.8 kW) Nat./LP

Summary of Contents for E-Series

Page 1: ...n 15 000 BTU side burners w porcelain V grates and stainless steel cover VGIQ530 models 53 W w four grill areas 7 8 sq ft 1 120 sq in TruSear infrared burner o Located in far left grill burner position o Constructed of heavy duty inconel stainless steel o 30 000 BTU high 17 500 BTU low VGIQ532 models 53 W w double side burners and three grill areas 5 8 sq ft 836 sq in Side burners a double configu...

Page 2: ... E Overall width 53 3 16 132 7 cm Overall height hood closed 26 7 8 68 3 cm With hood fully open 33 3 16 84 3 cm Overall depth from front of knobs 32 3 4 83 2 cm Approx ship wt lbs kg 460 208 8 490 222 5 460 208 8 490 222 5 VGBQ T Series grills are Star K certified for use on the Jewish Sabbath or Jewish holidays VGIQ grills are not Star K certified Dimensions Specifications PRODUCT DIMENSIONS VGB...

Page 3: ...ill exhausts combustion products and cooking greases to the back Never place the grill where the exhaust is directed at a window less than 24 61 0 cm to combustible material or any surface that is difficult to clean Allow at least 6 side clearance to non combustible construction above the cooking surface for counter space If using the rotisserie option the space is essential for motor and skewer c...

Page 4: ... P L A N N I N G A N D D E S I G N G U I D E V I K I N G R A N G E C O M 1 8 8 8 V I K I N G 1 R E L E A S E D 0 5 1 2 0 8 2 0 0 7 V R C INFORMATION SUBJECT TO CHANGE VGBQ530 4RT E T Series E Series Four Burner All Grill VGBQ532 3RT E T Series E Series Three Burner Grill w Side Burners VGIQ530 4RT E T Series E Series Four Burner All Grill inc TruSear Burner VGIQ532 3RT E T Series E Series Three Bu...

Page 5: ...are adapter LP propane tank installations Water column pressure o Operating pressure 10 WCP Includes high capacity hose regulator assembly for connection to a standard 5 gal 20 lb approx 12 diameter 18 H LP propane gas cylinder equipped with a Type 1 QCC 1 connector o The cylinder connection device must be compatible with the Type 1 QCC 1 connector on the outdoor cooking appliance o The cylinder m...

Page 6: ...y and adapter to mate with female fitting on the grill remove for mating hose to male fittings Vinyl Covers Sturdy reinforced vinyl exterior felt lined interior for protection Installation Notes Accessories Model Description Approx ship wt lbs kg TNK VGBQ Conversion kit LP propane to natural 3 1 2 TNK VGIQ Conversion kit LP propane to natural for TruSear grill 3 1 2 TLPK VGBQ Conversion kit natura...

Page 7: ...e items without needing to wire tie or spear Limited lifetime warranty Single basket Compliance Information WARRANTY SUMMARY One year full warranty complete product Lifetime limited warranty rust through on all stainless steel components including burners and porcelain grates Five year limited warranty grill burner assemblies infrared burners and porcelain grill grates under normal household use N...

Reviews: