background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

Fax Back Doc 191

ZF302450 Rev A

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

8

Entry Phone 1

E-50-SS shown

(Example: Front Door)

VIKING

©

MODEL C-2000A

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND

ENTRY PHONE CONTROLLER

1     2     3     4     5

6 7 8 9 10

11 12 13 14 15

16 17 18 19 20

21 22 23 24 25

26 27 28 29 30

PWR 13.8 V

A

C

EARTH GND

ENTR

Y

 PHONE 1

DOOR STRIKE 1

ENTR

Y

 PHONE 2

DOOR STRIKE 2

ENTR

Y

 PHONE 3

DOOR STRIKE 3

ENTR

Y

 PHONE 4

DOOR STRIKE 4

DOORBELL

 SWITCH /

AUX. INPUT

AUX. CONT

ACT

OUTPUT

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

C.O. / Phone

Line Input

To  Standard

Analog Touch

Tone House

Phone(s)

or

Entry Phone 4, K-1700-3 in VE-6x7 shown,
not included (Example: Gate)

Entry Phone 2, E-50-SS

shown, not included

(Example: Back Door)

To Entry Phone 4

(Power typically not 

required for gate controllers)

Doorstrike/

Magnetic Lock

5A@30VDC/
250VAC
maximum

A contact closure output is available for each

entry phone.  An auxiliary output is also available.

* Earth

Ground

(optional)

Optional Doorbell Switch
(not included, see Programming
section L on page 5)

Optional Postal Lock
(not included)

See DIP Switch Programming

Programming section C (page 4)

13.8V AC

Adapter

(included)

120V AC

Entry Phone 3, E-30 in VE-5x5 shown, not included
(Example: Garage)

To Gate
Controller

Tip (Audio)

Ring

Tip (Audio)

Ring

Video Out

Example:

2-4 Channel Video

RF Modulator

Example:

Amplified

RF Splitter

Video Out

Multi Room

Video Out

02

Antenna,

CATV, etc.

1       2      3      4

Model C-2000A (not included)

For more information on the C-2000A

retrieve Fax Back Document 156.

B.  One to Four Entry Phones Sharing a Single Phone Line with Optional Keyless Entry, 

Doorstrike/Gate Control, and Entry Phone Caller ID

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

A. Sharing a Single E-50 with an Existing Phone Line

SINGLE ENTRY PHONE

CONTROLLER

VIKING

©

MODEL C-200

PWR 13.8 V

AC

AUX RELA

Y

CONT

ACT

S

1

2

3

4

5

8

9 10

EARTH

GND 

PHONE LINE

INPUT

LINE OUT

TO PHONES

6

7

TO ENTRY

 PHONE

VIKING

ELECTRONICS

HUDSON, WI 54016

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

ENTRY
PHONE

N.O.   COM   N.C.
AUX CONTACTS

ON

 1     2     3

11 12

AUX POWER

 OUTPUT

AUX POWER

OUTPUT

RING COUNT

RELAY MODE

DOORBELL MODE 

* Earth Ground

(optional)

E-50-SS

shown

13.8V AC

Adapter

included

120V AC

Entry Door
Phone

Standard

Analog Phone(s)

-OR-

Analog Trunk / Line

Input of a Phone System

C.O. / Phone

Line Input

N.O. contacts to doorbell
switch, camera control, etc.

* Note:

To increase surge protection,

fasten a wire from the screw terminal
to Earth Ground (grounding rod,
water pipe, etc.)

Model C-200 (not included)

For more information on the C-200
retrieve Fax Back Document 169.

Summary of Contents for E-50 Series

Page 1: ...nless steel phone and camera mounting hardware and UV stable weather resistant powder coating excluding E 50 SS Optional Enhanced Weather Protection EWP available Vandal Resistant Features 16 gauge po...

Page 2: ...otal REN s contact the local telephone company For products approved after July 23 2001 the REN for this product is part of the product identifier that has the format US AAAEQ TXXXX The digits represe...

Page 3: ...h wing brackets can be used to secure the rough in box When mounting to surfaces thicker than 5 8 inch four standard flat head dry wall screws can be used to secure the Rough In box through its mounti...

Page 4: ...e required Need More Information on the PS 2R Call 715 386 4345 and select 512 E Wiring the E 50 Phone Board IMPORTANT Electronic devices are susceptible to lightning and power station electrical surg...

Page 5: ...desired position A portable service test monitor can be used to determine the correct viewing angle during installation Important To prevent the edge of the faceplate from being viewed in the video im...

Page 6: ...path in which the distant party cannot be heard over the speaker A microphone volume pot is provided for increasing or decreasing the microphone volume Note If the microphone volume is set too high o...

Page 7: ...5 minutes Silence time out for disconnect 10 90 seconds factory set to 1111 40 secs Talk listen delay VOX switching speed 0 1 0 9 seconds factory set to 111 0 3 secs Forced hang up command used to ex...

Page 8: ...ut is also available Earth Ground optional Optional Doorbell Switch not included see Programming section L on page 5 Optional Postal Lock not included See DIP Switch Programming Programming section C...

Reviews: