Rigid Connections (cont.)
• Installer-supplied intake pipes should be
checked visually for any foreign matter before
installing in a service line.
LP/Propane Conversion
The DGVU cooktops are shipped natural gas,
and manufactured for use with natural gas or
LP/Propane gas. Check the rating plate located
on the bottom of the burner box for type of
gas needed.
• To convert to natural gas or LP/Propane gas,
the orifice spuds and regulator must be
physically changed. Gas conversions must be
completed by a qualified service technician.
• The installer must use a flexible connector of at
least ½” I.D. (1.3 cm) NPT and comply with
ANSI Z21.41 and Z21.69 standards.
To convert from both natural to LP/Propane and
LP/Propane to natural a conversion kit is
supplied.
Before placing the cooktop into operation,
always check for gas leaks with a soapy
water solution or other acceptable method.
DO NOT
USE AN OPEN FLAME TO
CHECK FOR LEAKS.
CAUTION
Electrical & Gas Requirements
Initial Ignition of Burners
• All cooktops are tested before leaving the
factory. Field adjustments may be necessary for
proper mixture of gas and air for proper
operation. Contact a qualified technician to
make any necessary adjustments.
• The surface burners use electric igniters in
place of standing pilots.
Proper Lighting and Shutdown Instructions
To ignite electric igniters on the surface burners:
1. Turn the knob counterclockwise to any
position.
2. Upon ignition of the surface burner, turn the
knob to the desired position (HI, Med or Low).
3. To shutdown the burner, turn knob clockwise
to the OFF position.
In case of failure, shut the gas OFF using the
installer supplied manual shut-off valve.
Conversion must be performed by a
qualified installer, service agency, or the
gas supplier in accordance with the
manufacturer’s instructions. Failure to
follow instructions could result in serious
injury or property damage.
WARNING
Electrical power and gas must be turned
off prior to conversion.
WARNING