background image

IMPORTANT

• Before beginning, read these instructions

thoroughly and carefully.

• Installation and service must be

performed by a qualified installer, service
agency, or the gas supplier.

DO NOT

remove permanently affixed

labels, warnings, or plates from the
product as this may void the warranty.

• Observe all local and national codes,

requirements and ordinances.

• Installation must conform with local codes

or in the absence of codes, the National
Fuel Gas Code, ANSI Z223.1- latest
edition and the National Electrical Code,
ANSI/NFPA 70- latest edition.

In Canada:

Installation must be in

accordance with the current CAN/CGA
B149.1 & 2 Gas Installation codes and with
the current CSA C22.1 Canadian Electrical
Codes Part 1 and/or local codes.

• Installation of any gas-fired equipment

should be made by a licensed plumber.

• A manual gas shut-off valve must be

installed in the gas supply line ahead of
the cooktop in the gas stream for safety
and ease of service.

In Massachusetts:

This appliance must be

installed by a licensed plumber or gas-fitter.
A “T” handle manual gas valve must be
installed in the gas supply line to the
appliance.

• Installers should leave these instructions

with the consumer who should retain them
for the local inspector’s use and for future
reference.

3

Please Read and Follow

Your safety and the safety of others is
very important.

We have provided many important safety

messages in this manual and on your

appliance.

ALWAYS

read and obey all

safety messages.

This is the safety alert symbol. This

symbol alerts you to hazards that

can kill or hurt you and others.

All safety messages will be preceded by

the safety alert symbol and the word

“DANGER,” “WARNING” or “CAUTION.”

These words mean:

Hazards or unsafe practices

which WILL result in severe personal

injury or death

DANGER

Hazards or unsafe practices

which COULD result in severe personal

injury or death

Hazards or unsafe practices which

COULD result in minor personal injury

or property damage.

All safety messages will identify the

hazard, tell you how to reduce the chance

of injury, and tell you what can happen if

the instructions are not followed.

WARNING

CAUTION

Summary of Contents for Designer DGVU260-5B

Page 1: ...Viking Installation Guide Designer DGVU Built In Gas Cooktops...

Page 2: ...uirements _______________________________________________________12 General Information ________________________________________________________________14 Installation_________________________________...

Page 3: ...This appliance must be installed by a licensed plumber or gas fitter A T handle manual gas valve must be installed in the gas supply line to the appliance Installers should leave these instructions wi...

Page 4: ...serious illness and which are known to cause cancer birth defects or other reproductive harm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed i...

Page 5: ...d with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle DO NOT cut or remove the grounding prong from the plug F...

Page 6: ...6 30 3 4 78 2 cm 21 53 4 cm 28 1 8 71 4 cm 18 1 4 47 0 cm 10 3 16 27 1 cm 2 5 1 cm 2 5 1 cm 4 10 2 cm 2 13 16 7 1 cm Wiring diagram and rating plate location Power cord Regulator 7 3 16 18 4 cm 30 Ga...

Page 7: ...7 36 3 4 93 3 cm 21 53 4 cm 34 1 8 86 6 cm 18 1 4 47 0 cm 10 3 16 27 1 cm 2 5 1 cm 2 5 1 cm 4 10 2 cm 2 13 16 7 1 cm Wiring diagram and rating plate location Power cord Regulator 7 3 16 18 3 cm 36 Ga...

Page 8: ...lied with the product To field convert from natural or LP Propane the orifice spuds and regulator must be physically changed Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3 wire cord with ground...

Page 9: ...to 35 88 9 cm max B 19 48 3 cm min to 19 5 8 49 8 cm C 2 1 2 6 4 cm C E F D A B Note Refer to the downdraft installation instructions Downdraft Dimensions DGVU200 DGVU260 A 29 1 8 74 0 cm 34 7 8 88 6...

Page 10: ...mbustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high count...

Page 11: ...91 4 cm Wall Installation Island Installation Clearance Dimensions Wood Composite or Steel Overlay The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This wo...

Page 12: ...nstalled before any gas connections are made It is pre set for use with natural gas This must be converted to use with LP Propane gas Manifold pressure should be checked with a manometer Natural gas r...

Page 13: ...O NOT USE AN OPEN FLAME TO CHECK FOR LEAKS CAUTION Electrical Gas Requirements Initial Ignition of Burners All cooktops are tested before leaving the factory Field adjustments may be necessary for pro...

Page 14: ...position HI Med or Low To shutdown the burner turn knob clockwise to the OFF position In case of failure shut the gas OFF using the installer supplied manual shut off valve Site Preparation Note It i...

Page 15: ...there are no loose objects on the cooktop before turning upside down 3 Optional Gasket 4 Installation Peel away the plastic covering and place the gasket material all the way around the burner flange...

Page 16: ...etermine which injectors are needed for each burner Install and tighten injectors 5 Replace aluminum flame spreaders 1 Remove aluminum gas spreaders 2 2 2 2 2 1 Remove injectors using a 9 32 nut drive...

Page 17: ...or for different settings the function of the regulator must be checked at a pressure at least 1 WC 249Pa above the specified manifold pressure 2 1 2 Disconnect electrical power and shut off gas 1 3 1...

Page 18: ...oes not provide enough clearance for installing brackets on the front and back of the burner box install the brackets on the sides of burner box Final Installation Note Refer to Electrical Gas Require...

Page 19: ...ned for this material if build up occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted material soak with hot wet cloths t...

Page 20: ...ou will need it if service is ever required Model number ____________________________________________________________________________________ Serial number ____________________________________________...

Page 21: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 22: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 23: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 24: ...ing Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20680A EN 11040...