![Viking Designer DGVU2004BSS Installation Manual Download Page 10](http://html1.mh-extra.com/html/viking/designer-dgvu2004bss/designer-dgvu2004bss_installation-manual_1023748010.webp)
19
18
LP Conversion
3
60
105
105
90
105
90
115
60
115
4
1
1
1
1
2
Reference chart to determine which injectors are
needed for each burner.
Install and tighten injectors.
5
Replace aluminum flame spreaders.
1
Remove aluminum gas spreaders.
Unscrew regulator cap.
LP Pressure Regulator Conversion
4
2
1
Replace regulator cap.
5
Test gas pressure. When converting the regulator for different
settings, the function of the regulator must be checked at a pressure at
least 1” WC (249Pa) above the specified manifold pressure.
2
1
2
Disconnect electrical power and shut off gas.
1
2
2
2
2
2
1
Remove injectors using a 9/32” nut driver.
3
1
5
2
4
3
Unscrew the plastic conversion plug from the cap
and turn over. Screw plug back into cap with the wide
section away from cap.
LP conversion should only be performed
by a qualified service technician
WARNING