1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front M

MU

US

ST

T  B

BE

E unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 55

0

F (13

0

C) and below 110

0

F (43

0

C).  Best results

are obtained at temperatures between 65

0

F (18

0

C) and 80

0

F (27

0

C) for built-in models and between 65

0

F (18

0

C) and

90

0

F (32

0

C) for freestanding models.

3.  Provisions for electricity should be determined before placing unit in proper place.

U

Un

niittss  C

Ce

errttiiffiie

ed

d  ffo

orr  O

Ou

uttd

do

oo

orr  U

Usse

e  --  ((sstta

aiin

nlle

essss  sstte

ee

ell  o

ou

utte

err  cca

ab

biin

ne

ett))

MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR DRIP).
1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front M

MU

US

ST

T  B

BE

E unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 40

0

F (4

0

C) and below 110

0

F (43

0

C).  

3.  Provisions for electricity should be determined before placing unit in proper place.

N

No

otte

e::    H

Hiin

ng

ge

e  b

brra

acckke

ett  llo

occa

attiio

on

n  ssh

ho

ow

wn

n  iiss  ffo

orr  rriig

gh

htt--h

hiin

ng

ge

e  ssw

wiin

ng

g..

Door swing pin

Top hinge
bracket

Logo

Bottom hinge

bracket

Light switch activator

REVERSIBLE DOOR (Glass Door Units Only)
PROFESSIONAL SERIES

You can change the door swing from right to left hinge very easily.
1.  Simply unscrew the top hinge door swing pin with an 1/8” allen

drive unit and lift door off of the bottom hinge bracket.  Flip the
door, remove the light switch activator and replace the light switch
activator on the other end of the door.

2.  Remove the door swing pin from bottom right hinge.  Move the

bottom, right hinge bracket to the upper, left side of the cabinet
and fasten it in place with its original mounting screws.  

3.  Install the hinge door swing pin into the top right hinge bracket

and move the bracket to the lower left side of the cabinet.  Fasten
it in place with its original screws.  

4.  Place the plastic washer over the bottom door swing pin on the

top surface of the bottom, left hinge.  

5.  Position the door on the bottom, left hinge pin and push the door

under the top, left hinge.  

6.  Line-up the top left hinge hole with the door bushing hole and

insert swing pin.   Screw down the door swing pin with the 1/8”
allen drive unit until its head is flush with the top surface of the
top, left hinge.  

7.  Reposition the logo.  Your installation is now complete.

GENERAL INFORMATION

U

Un

np

pa

acckk

1.  Remove banding from bottom of carton.  Lift carton up and off of the refrigerated beverage center
2.  Remove all tape and packaging material from the outside and inside of the cabinet.
3.  Keep all carton packaging until your refrigerated beverage center has been thoroughly inspected and found to be in

good condition.

Summary of Contents for Designer DFUR140R

Page 1: ... is s located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the correct electric supply and grounding A 115 volt 60 Hz 15 amp fused electrical supply is required N NO OT TE E Time delay fuse or circuit breaker is recommended not used by anyone unable to operate it properly used o...

Page 2: ...ERCOUNTER CABINET CUTOUT A A 15 38 1 cm B B Min 34 1 2 87 6 cm Max 35 1 8 89 2 cm C C Min 24 61 0 cm C 15 38 1 cm width for cabinet only If door is recessed between cabinets cabinet cutout must be 15 1 4 38 7 cm ...

Page 3: ...r ri ic c D Da at ta a 115 VAC 60 Hz Maximum amps 3 0 Approximate Shipping Weight 110 lbs 49 5 kg Front View Side View 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 26 1 8 66 4 cm 37 3 16 94 5 cm ...

Page 4: ...roximate shipping weight 110 lbs 49 5 kg Front View Side View DUAR Side View DFUR 30 3 4 78 1 cm Mín 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 24 5 8 62 5 cm 21 3 16 53 8 cm 23 7 16 59 5 cm 37 3 16 94 5 cm 37 3 16 94 5 cm to front of locally supplied custom panel ...

Page 5: ...acing unit in proper place N No ot te e H Hi in ng ge e b br ra ac ck ke et t l lo oc ca at ti io on n s sh ho ow wn n i is s f fo or r r ri ig gh ht t h hi in ng ge e s sw wi in ng g Door swing pin Top hinge bracket Logo Bottom hinge bracket Light switch activator REVERSIBLE DOOR Glass Door Units Only PROFESSIONAL SERIES You can change the door swing from right to left hinge very easily 1 Simply ...

Page 6: ...door with the 10 32 machine screws and a 1 8 allen head driver as shown in Figure 1 below 2 Press in the shoulder bushings to the top and bottom door hinge brackets Make certain that the shoulder is to the outside of the door as shown in Figure 1 below 3 Test fit the door to the unit to make certain door will hang correctly The door is hung correctly when the top of the door is parallel to the top...

Page 7: ...oor 1 4 X 3 8 Deep hinge screw clearance hole Locate and drill using door hinge hole after the door has been aligned to the unit and when the wood is positioned on door Mounting surface Non face side Mounting surface non face side Mounting surface non face side Min 5 8 1 7 cm Max 3 4 1 9 cm 14 15 16 36 4 cm 7 5 32 18 2 cm 23 32 1 8 cm TYP 1 23 32 4 4 cm min width to cover door extrusion 23 32 1 8 ...

Page 8: ...Attach the door light striker plate as shown using the 5 16 hex or phillips head screws provided Make certain the light is able to turn on and off when the door is opened and closed 9 Attach the door to the unit by reversing step number 1 above CAUTION Door can become disengaged if washers are not installed CAUTION Door can become disengaged if washers are not installed Cabinet Hinge Wood Frame Do...

Page 9: ...tilting the unit to prevent it from falling on you while installing the leg levelers 2 Screw front two leg levelers into the screw impressions Leg levelers shoudl be screwed in until snug 3 Repeat steps 1 2 with the exception of tipping the unit forwards now to screw in the back two leg levelers 4 Your leg levelers are now installed 5 The unit should be level from front to back and side to side If...

Page 10: ... listed refrigerated products are equipped with this type of plug Power Supply with 3 prong grounding plug Grounding type wall receptacle FINAL PREPARATION 1 Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior of the refrigerated beverage center should be washed thoroughly with hot soapy water rinsed and wiped dry to remove film residue and any insta...

Page 11: ...io on ns s After making a temperture adjustment allow 24 hours for your refrigerated beverage center to reach a new temperature setting The motor will start and stop often It must do this to maintain the temperature setting Unplug the refrigerated beverage center before working on anything with the electrical system Exercise caution when sweeping vacuuming or mopping near the front of the unit Dam...

Page 12: ...s I In nt te er ri io or r Wash interior compartment with mild soap and water Do not use abrasive powder solvent polish cleaner or undiluted detergent S St ta ai in nl le es ss s S St te ee el l P Pa ar rt ts s All stainless steel parts should be wiped regularly with hot soapy water Use a liquid cleaner designed for stainless steel when soapy water will not do the job D Do o n no ot t u us se e st...

Page 13: ...o on n o of f p pa ar rt ts s u us se e o on nl ly y a au ut th ho or ri iz ze ed d p pa ar rt ts s t to o e en ns su ur re e p pr ro ot te ec ct ti io on n u un nd de er r t th he e w wa ar rr ra an nt ty y T Th hi is s m ma an nu ua al l s sh ho ou ul ld d r re em ma ai in n w wi it th h t th he e r re ef fr ri ig ge er ra at to or r f fo or r f fu ut tu ur re e r re ef fe er re en nc ce e TROUB...

Page 14: ...roper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whether arising out ...

Page 15: ...r to the product for any reason alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequen...

Reviews: