background image

5

IMPORTANT

4

Please Read and Follow

WARNING

To prevent possible damage to cabinets

and cabinet finishes, use only materials

and finishes that will not discolor or

delaminate and will withstand temperatures

up to 194

°

F (90

°

C). Heat resistant

adhesive must be used if the product is to

be installed in laminated cabinetry. Check

with your builder or cabinet supplier to

make sure that the materials meet these

requirements.

A GFI

shall be used if required by NFPA-70 (National Electric Code), federal/state/local

laws, or local ordinances.

• The required use of a GFI is normally related to the location of a receptacle with respect to

any significant sources of water or moisture.

• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which

are not installed properly or do not meet the requirements below.

If the use of a GFI is required

, it should be:

• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT

recommended)

• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible

DANGER

ELECTRICAL SHOCK
HAZARD

To avoid risk of electrical shock,

personal injury or death; verify your

appliance has been properly grounded in

accordance with local codes or in absence

of codes, with the National Electrical

Code (NEC). ANSI/NFPA 70-latest edition.

WARNING

MOVING HAZARD

To avoid risk of severe personal

injury; this appliance requires

two or more personnel while handling and

moving. Possible use of appliance moving

devices is recommended.

Summary of Contents for Designer DERT302-4B

Page 1: ... Designer Built In Electric Rangetops Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20576D EN 092209J ...

Page 2: ...se instructions completely and carefully DO NOT remove permanently affixed labels warnings or plates from product This may void the warranty All local and national codes and ordinances must be observed Installation must conform with local codes The installer must leave these instructions with the consumer who should retain for local inspector s use and for future reference In Canada Installation m...

Page 3: ... GFI is required it should be Of the receptacle type breaker type or portable type NOT recommended Used with permanent wiring only temporary or portable wiring NOT recommended On a dedicated circuit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as per UL...

Page 4: ...kw 208V 29 8 amps 6 2 kw 240V 49 2 amps 11 8 kw 208V 42 6 amps 8 9 kw Surface element rating Left front dual element Left front single element Left rear dual element Left rear single element Center front rear Bridge Right front Right rear dual element Right rear single element 240V 208V N A N A 1 500 watts 1 125 watts 2 500 1 000 watts 1 875 750 watts N A N A N A N A 800 watts 600 watts 1 800 watt...

Page 5: ...ar dual element 240V 208V 1 800 watts 1 350 watts 800 watts 600 watts 1 800 watts 1 350 watts N A N A 1 500 watts 1 125 watts 2 500 1 000 watts 1 875 750 watts 240V 208V 1 800 watts 1 350 watts 800 watts 600 watts 1 800 watts 1 350 watts 2 700 1 700 watts 2 025 1275 watts 1 500 watts 1 125 watts 2 200 750 watts 1 650 560 watts Approximate shipping weight 52 lbs 23 4 kg 63 lbs 28 4 kg Minimum clear...

Page 6: ...D To avoid risk of personal injury the use of cabinets for storage above the appliance may result in a potential burn hazard Combustible items may ignite metallic items may become hot and cause burns If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum 5 12 7 cm beyond the bottom of cabinets Note Based on 24 61 cm deep cabine...

Page 7: ...or this material If buildup occurs DO NOT use steel wool abrasive cloths cleaners or powders Electrical Requirements Electrical Requirements Check your national and local codes regarding this unit This rangetop requires 3 wire 240 208 VAC 60 Hz See Installation section for grounding instructions Must be fused seperately from any other circuit Electrical connection in this area 3 4 1 9 cm minimum C...

Page 8: ...ace indicator lights glow red when corresponding element is on All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wool ...

Page 9: ..._______________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ______...

Page 10: ...19 18 ...

Reviews: