Viking DCWH series Installation Instructions Manual Download Page 3

5

IMPORTANT–

Please Read and Follow!

4

W A R N I N G

TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY 
TO PERSONS

Rangehoods must be installed with
the ventilators that are specified on
their carton indicating suitability with
this model. Other ventilators cannot be substituted.

C A U T I O N

For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.

W A R N I N G

To reduce the risk of injury to persons in the
event of a rangetop grease fire, observe the
following. (Based on “Kitchen Firesafety Tips,”
published by NFPA.)

1. SMOTHER FLAMES with a close fitted lid, cookie

sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN. You may be

burned.

3. DO NOT USE WATER, including wet dishcloths or

towels a violent steam explosion will result.

4. Use an extinguisher ONLY if

• You know it is a Class ABC extinguisher, and you

already know how to operate it.

• The fire is small and contained in the area where

it started.

• The fire department is being called.
• You can fight the fire with your back to an exit.

Dimensions & Specifications

(VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”)

* Disregard when using recirculating kits.
460 CFM blower is shipped with hood.

NOTE:

Optional duct cover sold separately.

VWH 10”H. Wall Hoods w/Standard Ventilator

Description

24”

30”

36”

Duct cover width

23-7/8” (60.6 cm)

29-7/8” (75.9 cm)

35-7/8” (91.1 cm)

Duct cover depth

12” (30.5 cm)

Duct cover height

12” (30.5 cm)

Number of lights

2

Number of filters

2

Heat lamps

N/A

Interior ventilator kit

460 CFM Standard

Interior duct size*

7” (17.8 cm)

Interior—Maximum amps

5.6

Summary of Contents for DCWH series

Page 1: ...allation Guide Professional Outdoor Hoods Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking...

Page 2: ...ore servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secur...

Page 3: ...HE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if You know it...

Page 4: ...6 Clearance Dimensions 7 Interior Ventilator Dimensions 460 CFM Interior Ventilator Installation Top View VWH 10 H Wall Hoods w Standard Ventilator VWH 10 H Wall Hoods w Standard Ventilator...

Page 5: ...s Description 30 36 42 48 54 60 Duct cover width 29 7 8 75 9 cm 35 7 8 91 1 cm 41 7 8 106 4 cm 47 7 8 121 6 cm 53 7 8 136 8 cm 59 7 8 152 1 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm...

Page 6: ...Installation for all Wall Hoods 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Wall Hoods 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 1200 CFM Interior Ven...

Page 7: ...e 30 76 2 cm to 36 91 4 cm above the grill surface The hood should be installed 4 1 2 11 4 cm plus the distance between the back trim and surface from the back wall Note There is a 3 minimum clearance...

Page 8: ...4 60 66 Duct cover width 12 30 5 cm 12 30 5 cm 12 30 5 cm 18 45 7 cm 18 45 7 cm 24 61 0 cm 24 61 0 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm to 24 61 0 cm Number of lights 2 2 2 3 3...

Page 9: ...n for 30 36 42 models 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for 48 54 60 66 models 300 or 600 CFM Interior Ventilator Installation for 30 36 42 models 1200 CFM Interior Vent...

Page 10: ...4 cm 12 30 5 cm 12 30 5 cm 18 45 7 cm Duct cover depth 12 30 5 cm Duct cover height 18 45 7 cm to 30 76 2 cm 16 40 6 cm to 28 71 1 cm 16 40 6 cm to 28 71 1 cm 16 40 6 cm to 28 71 1 cm Number of lights...

Page 11: ...r 30 36 42 Hoods 900 or 1200 CFM Exterior or In Line Ventilator Installation for 30 36 42 Hoods Top View Top View Top View Top View 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for...

Page 12: ...al duct cover sold separately VCIH Chimney Island Hoods 36 42 54 66 VCIH Chimney Island Hoods Description 36 42 54 66 Duct cover width 12 30 5 cm 12 30 5 cm 18 45 7 cm 24 70 0 cm Duct cover depth 12 3...

Page 13: ...ney Island Hoods 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Chimney Island Hoods 600 CFM Interior Ventilator Installation for all Chimney Island Hoods 1200 CFM Interior V...

Page 14: ...the ventilator system may be mounted as shown on page 25 Installing Hood Canopy Custom Hood Canopy 1 Position ventilator system inside of the custom hood canopy and center it front to back and left t...

Page 15: ...nterior Ventilator Installation 900 or 1200 CFM Exterior or In Line Ventilator Installation 30 36 42 W Models 300 or 600 CFM Interior Ventilator Installation 30 36 42 W Models C 30 W 28 1 4 71 8 cm 36...

Page 16: ...each 90 elbow is equivalent to 5 10 feet 1 52 3 05 cm of straight run Never use flexible duct it creates back pressure air turbulence and greatly reduces performance Proper performance is dependent on...

Page 17: ...re Text goe here Text goe here Text goe here Text goe here Check damper for unrestricted movement adjust if necessary Attach transition to damper Seal with aluminum tape Flip hood over and remove elec...

Page 18: ...rer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locke...

Page 19: ...net framing use additional mounting screws if necessary Slide filter front over front lip Push filter rear up then slide back over rear lip 36 Connect black to black white to white and the green bare...

Page 20: ...vided Measure distance from ceiling to canopy Tape to avoid scratching Duct Cover Option VCWH Chimney Wall Hoods 38 Slide spacer front over front lip Push spacer rear up then slide back over rear lip...

Page 21: ...Number of spacers and baffles may vary by model Slide filter front over front lip Push filter rear up then slide back over rear lip 40 Check framing where cutout will be NOTE 200 lb limit Cut appropr...

Page 22: ...crews and wall anchors if necessary CAUTION If not using a duct cover using screws provided make sure top mounting screws are secured into soffit or cabinet frame Use additional mounting screws if nec...

Page 23: ...d it if service is ever required The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy Model number ___________________...

Page 24: ...47 46...

Reviews: