PRODUCT MANUAL

Designed, Manufactured and Supported in the USA

C O M M U N I C A T I O N   &   S E C U R I T Y   S O L U T I O N S

CTG-2A

Networked Clock Controlled 

Tone / Message Generator

and Master Clock

January 31, 2017

        VIKING

Features

Applications

Specifications

Add Master Clock Controlled CD Quality Tones or

Messages and Emergency Tones to Your Paging System

•  Up to 14 Schedules and up to 1,000 Events
•  6 minutes of CD quality WAV file record time
•  Up to 14 different tones or messages
•  4 programmable trigger inputs for emergency tones, etc.
•  Automatic Day Light Savings Time and leap year correction
•  Programmable NTP Clock synchronization
•  PC programming software included
•  RS485 clock SYNC terminals for remote Master Clock control of

Viking CL Series 

RF synchronized clocks 

•  Non-volatile memory with 4 day clock back up
•  Factory loaded with school/factory tones and evacuation signals

(ANSI S3.41), etc.

•  Remote program via TCP/IP network 
•  Page trigger outputs (12VDC and DPDT relay)
•  Programmable Auxiliary relay contacts (DPDT)
•  24 hour digital clock displays hours & minutes
•  One mono line level pre-amp input and audio output
•  Built-in 1 Watt mono audio amplifier
•  One isolated audio output for PABX / dial access paging
•  Master volume control
•  Programmable volume control per tone/message
•  Time base selection: Network, 50/60Hz or internal
•  Programmable message repeat count for trigger inputs

Internal Clock Backup Time:  

4 days

Power:  

120V AC/13.8V AC 1.25A UL listed adapter provided, max current draw: 650mA

Dimensions:

8.25” x  6.25” x  1.75” (210mm x 159mm x 45mm)

Weight:

3.2 lbs  (1.5 Kg)

Environmental: 

32°F to 90°F (0°C to 32°C) with 5 - 95% non-condensing humidity

Preamp (Audio 1/2) Output:

6V RMS across 600 ohms

Paging Amplifier Output:  

1 watt - powers up to (2) 8 ohm or (12) 45 ohm speakers

Sound Pressure:

85 dB @ 1 meter (loud electronic warble from 25AE paging horn)

Maximum Speaker Output Wire Run:

91m (300 ft), 18 AWG

Maximum Load on Page Trigger Output:

750 ohm (15mA)

WAV File Resolution: 

16 bit or 8 bit

WAV File Sampling Rate:

90 sec. of 44.1K, 3 min. of 22K or 6 min. of 11K

Time Base: 

50/60 Hz or internal with NTP clock sync

Internal Time Base Accuracy:

+/- 2ppm (63 seconds per year) without network time sync

or manual adjustment

Connections: 

29 screw terminal block positions, (1) RJ45 network jack

Viking’s model 

CTG-2A

is a networked clock controlled tone/message

generator designed to provide accurately timed tones and/or messages
over your existing paging system. This provides a cost effective way of
signaling school period changes, factory shifts, breaks, lunch periods,
etc. The 

CTG-2A

has four programmable trigger inputs which are ideal

for triggering emergency alert tones/messages to indicate fire
evacuation, severe weather, lock down, all clear or can be used in store
caster applications for “customer service required” announcements, etc.
The 

CTG-2A

can also be used as a master clock to synchronize Viking

CL Series

wireless clocks (see DOD# 466).

The 

CTG-2A

comes equipped with up to 6 minutes of CD quality WAV

file audio storage for up to 14 different tone/messages. The unit is
factory loaded with common school, business and factory tones but can
be programmed with your custom tones/messages or updated from the
list of WAV files from the Viking web site. 

The 

CTG-2A

can be programmed with up to 14 schedules and up to

1,000 events allowing you to program an entire year or multiple years
of schedules in advance. The 

CTG-2A

’s extremely accurate time base

can be manually synchronized, synchronized with 50 or 60 Hz power
or can be programmed to periodically synchronize to 

network or

internet time.

•  Signal the beginning and end of class periods, breaks and lunch periods for schools

•  Signal the beginning and end of shifts, breaks and lunch periods for factories/businesses

•  Provide trigger controlled emergency alert messages for fire, flood, severe weather, lock

down, etc.

•  Provide messages at specific times for store sales, promotions, closing times, airport

loading zones, etc.

•  Provide Auxiliary contact activation at specific times for specific durations for controlling

lights, cameras, unlocking doors/gates, etc.

•  The 

CTG-2A

can also be used as a Master Clock to synchronize 

Viking CL Series

wireless clocks (

DOD# 466

)

The 

CTG-2A

comes with programming software and a network port to

allow PC programming of timed events, schedules, clock
synchronization, wave file download, message volume, day light
savings time, auxiliary relay control, etc.

Installation requires the assistance of a

Network Administrator / IT Technician.

!

Summary of Contents for CTG-2A

Page 1: ...ar without network time sync or manual adjustment Connections 29 screw terminal block positions 1 RJ45 network jack Viking s model CTG 2A is a networked clock controlled tone message generator designed to provide accurately timed tones and or messages over your existing paging system This provides a cost effective way of signaling school period changes factory shifts breaks lunch periods etc The C...

Page 2: ...me sync Time Switch Press to advance through time schedules initiate a force time sync or turn unit back on Time Switch Press to decrement time select schedules or turn unit off RS485 Clock Sync Output Connects to CL RFT for synchronizing time on Viking CL Series wireless clocks DOD 466 Network RJ 45 Ethernet jack for programming uploading WAV files and NTP time syncing Trigger Inputs 1 4 For acti...

Page 3: ...ster volume to match paging level from phone system and or 1 8 mono plug 13 8V AC Adapter included 120V AC NETWORK B Using the CTG 2A as a Master Clock to Automatically Synchronize Viking s CL Series Wireless Clocks Viking s Wireless Clock System provides reliable accurately synchronized clocks for your entire facility Eliminating dedicated clock wiring can save you thousands of dollars on install...

Page 4: ...only to certain zones of a multi zone paging system Another application is connecting the CTG 2A to the override port of a multi zone page controller so the CTG 2A wave files are a higher priority than a voice page See the Creating Touch Tone Wave Files application note DOD 898 Audacity can generate the required touch tones Notes 1 The CTG 2A can only play one tone message at a time at the top of ...

Page 5: ...R INPUT 1 TRIGGER INPUT 2 TRIGGER INPUT 3 P M 14 15 SPEAKER OUTPUT 18 19 AUDIO OUTPUT 16 17 AUDIO INPUT 7 8 TRIGGER INPUT 4 Paging Port of PABX KSU NETWORK Paging Amplifier not included Paging Amplifier not included The CTG 2A can play wave files to send timed tones messages to individual zones a combination of zones or all zones You simply add a brief touch tone before each tone message using Aud...

Page 6: ... TRIGGER INPUT 2 TRIGGER INPUT 3 P M 14 15 SPEAKER OUTPUT 18 19 AUDIO OUTPUT 16 17 AUDIO INPUT 7 8 TRIGGER INPUT 4 Unused PABX KSU Trunk Port NETWORK Paging Amplifier not included Paging Amplifier not included Notes 1 The CTG 2A can only play one tone message at a time at the top of a minute If multiple tones or messages must play at the same time multiple CTG 2A s must be used 2 The CTG 2A is lim...

Page 7: ...trol A MAC address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers to send network traffic to the correct IP address You can find the MAC address of your CTG 2A printed on a white label on the top surface of the network port NTP NTP is the abbreviation for Network Time Protocol It al...

Page 8: ...nk dialogs appear click No 10 In the menu bar click File then Open 11 In the menu bar click Tools then Load All 12 Click Close 13 Click Upload 14 Click Clock 15 If migrating from a CTG 2 click Read PC s Settings 16 Click NTP Sync 17 When asked to upload the clock parameters click Yes 18 Once the sync is complete click OK 19 Click Close 20 In the menubar click Tools then Username Password 21 Enter ...

Page 9: ...ons on the screen To start the CTG 2A application click on the CTG 2A Programmer icon on your desktop When you first start the program the Connect screen will appear The software will scan the local network for the CTG 2A automatically when this screen is started Select a device from the list or enter its address in the field and click Connect If you want to work offline click Work Offline When yo...

Page 10: ... to the CTG 2A open the drop down menu and click on the missing wave file The file will then be automatically uploaded to the CTG 2A WAV File Guidelines 1 For best results the WAV file should be 16 bit 44 1K mono 2 Resolution down to 8 bits is acceptable but audio quality will not be optimal 3 Sampling rates of 22k and 11k are also acceptable 4 The WAV file may be stereo or multi channel but only ...

Page 11: ...e name Select the memory location you would like to change and alter the volume using the Volume box at the bottom of the window Update All After adjusting the wave file volume levels adjusted volume settings will be highlighted in red select Update All to save the volume settings for all wave files Load All In the Tools drop down menu selecting Load All will upload all the wave files from the cur...

Page 12: ...approximately 63 seconds per yr This accuracy can be greatly increased by programming Time Sync events daily or weekly We recommend programming the Time Sync Start Time for after hours and at an odd time to help minimize server load Do not perform time syncs more frequent than twice an hour Duration For a timed Relay event this box sets the length of time the auxiliary relay will be actuated Time ...

Page 13: ... schedule change Additional information about manual schedule changes 1 Multiple schedule changes on a particular day are not supported 2 The start and stop times for all manual schedule changes is fixed at midnight and cannot be changed The Start Time field on the Edit Event screen is grayed out not available when programming a schedule change event 3 When all programming is completed and uploade...

Page 14: ...preprogrammed schedule Click on Start and the CTG 2A will begin running the selected schedule 14 Block Edit This screen opens after single clicking in the Event row By clicking and highlighting entire blocks of events can be selected This is used to Copy Cut Paste Insert or Delete single or multiple Event rows This can be useful for copying an entire schedule then modifying the event times slightl...

Page 15: ...lock calibration etc Clock Clicking the Clock button will open the Clock programming screen where you can enter program Clock Parameters such as Time base Internal 50 Hz or 60Hz Time Zone and Daylight Savings Time program Clock Time Manual PC time or NTP Sync and program Time Server Settings Note It is recommended that you use the Internal time base which has an accuracy of 2 ppm 63 seconds per ye...

Page 16: ... Network Time Protocol It allows computers to synchronize time over the internet or a local network The address can be an IP address or a URL a local or a server on the internet This field is factory loaded with the internet server pool 0 viking pool ntp org This setting is not stored in the dat file NTP port This is the UDP port the time server uses Only change this value if instructed by your ne...

Page 17: ...the PC and the CTG 2A and a message will pop up saying the CTG 2A is missing some of its wave files when they are not missing If you get this type of error message close the software and re open it 2 A similar miscommunication can cause the Login prompt to appear repeatedly if this happens close the software and re open it If you are again prompted for the login you can reset the CTG 2A s login an...

Page 18: ...when the CTG 2A has lost power for over 4 days and has dates or daylight savings time programmed This can be corrected with a Time Sync see below or enter PC programming and reprogram the clock in the Clock screen see page 15 dS Displayed when the CTG 2A is in the System Disable mode see System Disable page 12 OFF Displayed when the CTG 2A is in the Off mode In the Off mode the CTG 2A will not pla...

Page 19: ...re ignored Auxiliary Relay Operation The auxiliary relay can be either timed or continuously activated through clock events If the auxiliary relay is currently activated because of an event and AC power is lost even momentarily the auxiliary relay will no longer be activated when power is restored If this type of operation is not desirable a UPS is recommended for the CTG 2A power If an auxiliary ...

Page 20: ...e TWO YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any time during the warranty period the product is deemed defective or malfunctions return the product to Viking Electronics Inc 1531 Industrial Street Hudson WI...

Reviews: