Viking CTG--1 Technical Practice Download Page 5

C. Turning the Alert Tones On/Off for Specific Days of the Week

D. Setting Timed Alert Tones

Note: 

If more than 128 events have been entered, a long beep will be heard indicating that the event memory is full.

E. Reviewing and/or Cancelling Timed Alert Tones

F. Adjusting Output Volume

G. Activating Contact Closure Alarm Tones

To activate different sounds, short the corresponding pins with a
dry contact closure as shown right (see 

Installation

, section 

A

). 

Note:

The evacuation sound and siren will be repeated continu-

ously, as long as the closures are maintained.

Step 1.

Press the 

MODE

button repeatedly until the 

SET DAY

indicator lights. The current day of the week and “

on

” or “

of

” will

be displayed. “

on

” = alert tones are ON and “

of

” = alert tones are OFF for that day of the week.

Step 2.

Pressing the 

SINGLE

button will toggle between flashing the day of the week and flashing “

on

” or “

of

”. The flashing por-

tion of the display is the section that can be changed.

Step 3.

With the day of the week flashing, use the 

TIME

(

+

and 

-/CANCEL

) buttons to select the day of the week you would like

to set to ON or OFF.  When the correct day of the week is displayed, press the 

SINGLE

button to flash “

on

” or “

of

”.  The

day can then be set to ON or OFF by using the 

TIME

(

+

and  

-/CANCEL

) buttons.

Step 4.

Review your day of the week programming by pressing the 

SINGLE

button until the weekday (1-7) is flashing, then incre-

ment through each day of the week with the 

TIME

(

+

) button and monitor each day for its on or off setting.  Exit the 

SET

DAY

mode by simply pressing the 

MODE

button.

Step 1.

Press the 

MODE

button repeatedly until the 

SET EVENTS

indicator lights.

Step 2.

Increase or decrease the event time by pressing the 

TIME

(

+

or 

-/CANCEL

) button until the desired time is shown.

Step 3.

Move DIP switch 2 to 

OFF

for bong alert tones or 

ON

for buzzer alert tones (see 

Programming

section 

J

).

Step 4.

Press one of the single, double, or triple 

ALERT TONES

buttons to program the number of alert tones you wish to out-

put at the specific event time.  A single, double, or triple confirmation beep should be heard.

Step 5.

Repeat steps 2-4 for the remainder of your scheduled events.

Step 1.

Press the 

MODE

button repeatedly until the 

REVIEW/CANCEL

indicator lights.

Step 2.

Press one of the 

ALERT TONES

buttons (single, double, or triple) repeatedly to rotate through the event times associ-

ated with that alert tone button. A red LED at the bottom right corner of the time display will light to indicate a buzzer
event time (versus a bong event). 

Note: 

Event times are stored in the order of programming, not chronologically.

Step 3.

Press the 

-/CANCEL

button to permanently cancel an event tone.  A single acknowledgement tone will be heard.  The

next consecutive event for that specific alert tone will then be displayed.

Step 4.

Repeat steps 2-3 as needed to remove the events to be cancelled.

Step 5.

When all events for a given alert tone have been cancelled, the display shows three dashes (- - -).

Step 1.

Short pins 

9

and 

12

together momentarily.  The doorbell sound will then chime once.

Step 2.

Adjust the volume control potentiometer (see 

Installation

).

Step 3.

Repeat steps 1-2 until the desired volume is achieved.

Sound

Short Pins...

Doorbell (Ding Dong)

...9 to 12

Evacuation Sound (Slow Whoop)

...10 to 12

Siren (Yelp)

...11 to 12

5

Summary of Contents for CTG--1

Page 1: ...audio output Non volatile programming memory Battery backup for maintaining clock time with factory installed 9V NiMh rechargeable battery Two sets of DPDT relay contacts for muting paging or backgro...

Page 2: ...erence to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own...

Page 3: ...nt when reviewing programming Alert Tones Programming Buttons After setting an event time press SIN GLE DOUBLE or TRIPLE to program 1 2 or 3 alert bongs buzzer sounds for that event time Secondary But...

Page 4: ...of Paging Amp or Common Siren Evacuation Signal Doorbell Dry Contact Closures from Alarm Equipment Doorbell Switch Etc I In ns st ta al ll la at ti io on n Step 1 Press the MODE button repeatedly unt...

Page 5: ...ng the MODE button Step 1 Press the MODE button repeatedly until the SET EVENTS indicator lights Step 2 Increase or decrease the event time by pressing the TIME or CANCEL button until the desired time...

Page 6: ...upport at 715 386 8666 J DIP Switch and Shunt Settings Internal View of the CTG 1 1 2 ON ON OFF 60 Hz installed 50 Hz removed Turn DIP switch 1 OFF Unplug the CTG 1 from power Pause a few seconds and...

Page 7: ...z 60 Hz 60 Hz 500 Hz 3 sec 500 Hz 3 sec 500 Hz 3 sec 1 sec 1 sec 1 sec Single Double Triple 3 second break then repeated a second time 3 second break then repeated a second time Continuously repeated...

Page 8: ...Ot th he er r A Ap pp pl li ic ca at ti io on ns s The store will be closing in 10 minutes Please bring all items to the check out or To Input of Paging Amplifier Model M15W shown not included Backgro...

Reviews: