General Information

READ AND FOLLOW ALL WARNING
AND CAUTION INFORMATION WHEN
INSTALLING THIS APPLIANCE.

• Keep appliance area clear and free from

combustible materials, gasoline and other
flammable vapors.

• Disconnect the electrical supply prior to

servicing or cleaning.

• When removing the cooktop for service

and/or cleaning, disconnect AC power sup-
ply.

• Electrical requirements are listed in the

product specifications under the “Electrical
Requirements” section.

Installation

1

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

2

Ground

Green

Black

Red

Lower cooktop into cutout.

Connect the red and black leads from the unit conduit

to the corresponding leads in the junction box.

Cooktop

Bracket

Countertop

3

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

4

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

Screw brackets to burner box with sheet metal screw.

(Two bracket assemblies included)

Screw sheet metal screws into brackets

and tighten firmly against bottom of countertop.

Note:

Be careful not to crack or damage

counter by overtightening.

Electrical Requirements

12

Electrical Requirements

Check your local codes regarding this unit.
This cooktop is supplied with a 3-wire,
240/208 volt, 60 HZ electrical system. A
white (neutral) is not needed for this unit. See
next section for grounding instructions. It
should be fused separately.

Refer to the specifications chart for kilowatt
rating and recommended amperage. House
wiring and fusing must comply with local
codes. If no local codes are applicable, wire
in accordance with the National Electrical
Code, ANSI/NFPA 70-latest edition.

Electrical Connection

When making the wire connections, use the
entire length of the conduit provided (3 feet).
The conduit must not be cut. Connect the
red and black leads from the unit conduit to
the corresponding leads in the junction box.
The bare ground wire in the conduit is con-
nected to the unit frame. When connecting
to a 3-conductor branch circuit, if local codes
permit, connect the bare ground connector
lead of the unit to the branch circuit neutral
(gray or white in color).

WARNING

ELECTRICAL

GROUNDING

INSTRUCTIONS

This cooktop must be electrically

grounded in accordance with local codes

or, in the absence of codes, with the Na-

tional Electrical Code, ANSI/NFPA 70-lat-

est edition.

FOR PERSONAL SAFETY,

THIS APPLIANCE MUST BE PROP-

ERLY GROUNDED.

CAUTION

Be sure the electric power is

off from the breaker box to the

junction box until the cooktop

is installed and ready to oper-

ate. The junction box should be con-

nected to a suitable ground.

WARNING

The electrical power to the

unit must be shut off while line

connections are being made.

Failure to do so could result

in serious injury or death.

WARNING

FIRE AND ELECTRICAL

SHOCK HAZARD

DO NOT

use an extension cord

with this appliance. Such use

may result in fire, electrical

shock, or other personal injury.

Summary of Contents for Built-In Electric Induction/Radiant Cooktop

Page 1: ...diant Cooktop Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com...

Page 2: ...warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer must leave...

Page 3: ...ppliance may result in potential burn haz ard Combustible items may ignite metallic items may become hot and cause burns If a cabinet storage is to pro vided the risk can be reduced by installing a ra...

Page 4: ...40V 37 9 amps 9 1 kw 208V 35 4 amps 7 4 kw 240V 55 0 amps 13 2 kw 208V 50 2 amps 10 4 kw Surface element rating Right front Right rear Center front Bridge Center rear Left front Left rear 240V 208V 1...

Page 5: ...e shelf underneath is 18 45 7 cm There should be no partition or shelf directly underneath the unit It is also required that the exit air ports at the rear are not blocked There should be a mini mum o...

Page 6: ...36 91 4 cm counter height Within the 6 15 2 cm side clearance to com bustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2...

Page 7: ...efer to the specifications chart for kilowatt rating and recommended amperage House wiring and fusing must comply with local codes If no local codes are applicable wire in accordance with the National...

Page 8: ...g service on the cooktop DO NOT repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Contact Vikin...

Reviews: