Viking 30

3/8” 

3/8” 
male 

male 
flare 

flare 
dapter

dapter

3/8” 
male 
flare 
adapter

Installer supplied 
flexible gas line
with 3/8” female 
adapter or Viking 
GHS12

Installer supplied 
shut-off valve must 
be easily accessible

3/8” female 

flare adapter

Regulator 

Assembly

3/8” male 
flare adapter

LP/Propane Fixed Piping Connection

Check with your local gas utility company or with
local codes for instructions on installing gas
supply lines. Be sure to check on type and size of
run and how deep to bury the lines. If the gas line
is too small, the grill will not function properly.

To connect the supplied regulator assembly to
the incoming flexible gas line, attach with a 3/8”
female flare adapter to the 3/8” male flare

adapter to the regulator assembly. Ensure that
the regulator arrow points in the direction of the
gas flow towards the unit and away from the
supply. Attach the regulator assembly to the grill
unit with the 3/8” female flare adapter on the
regulator assembly to the 3/8” male flare adapter
on the grill. 

Do not forget to place the

installer supplied gas valve in an
accessible location

25

Male 

Male 
coupler

coupler

Male 
coupler

Installer supplied 
flexible gas line
with 1/2” female 
adapter or Viking 
GHS12

Installer supplied 
shut-off valve must 
be easily accessible

female 
coupler

7/8” male 
flare adapter

Regulator 

Assembly

Natural Fixed Piping Connection

Check with your local gas utility company or with
local codes for instructions on installing gas
supply lines. Be sure to check on type and size of
run and how deep to bury the lines. If the gas line
is too small, the grill will not function properly.

To connect the supplied regulator assembly to
the incoming flexible gas line, attach with a 7/8”
(2.2 cm) female flare adapter to the 7/8” (2.2 cm)
male flare adapter on the regulator assembly.
Ensure that the regulator arrow points in the
direction of the gas flow towards the unit and
away from the supply. Attach the regulator

assembly to the grill unit by pulling back the
female coupler sleeve towards the regulator.
Insert the coupler into the male coupler fitting on
the grill until the sleeve snaps forward securing
the connection. 

Do not forget to place the

installer supplied gas valve in an
accessible location.

Note: 

If using a Viking GSH12 flexible hose,

remove the 1/2” flare adapter and attach
hose to the 7/8” (2.2 cm) male flare on the
regulator assembly.

24

Connection

Operating Pressure

Supply Pressure

Standard Residential 1/2" ID gas
service line - 1/2" NPT male with

7/8" (2.2 cm) flare adapter.

4.0" W.C.P. Nat.

6" to 10" W.C.P. Nat. If in excess 

of 10" W.C.P., a step-down 

regulator is required.

Connection

Operating Pressure

Supply Pressure

Standard Residential 1/2" ID gas
service line - 1/2” NPT male with

3/8" flare adapter.

10.0" W.C.P. LP/Propane

11" to 14" W.C.P. LP. If in excess 

of 14" W.C.P., a step-down 

regulator is required.

Summary of Contents for 30" W 100 Series

Page 1: ...Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20896B EN 0...

Page 2: ...A C22 1 CAUTION Before placing into operation always check for gas leaks with a soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS DANGER WHAT TO DO IF YOU SMELL GAS Shut off gas to the...

Page 3: ...3 cm ID gas service line LP Propane Equipped with high capacity hose regulator assembly for connection to standard 5gal 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection or standard resident...

Page 4: ...uirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor...

Page 5: ...l 1 2 1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 p...

Page 6: ...tor requires a separate 110 120 volt supply to be located on the right hand side of the grill Both the power supply cords for the ignition lights and the rotisserie motor are equipped with a 3 prong g...

Page 7: ...ustable surface 6 15 2 cm Clearance Dimensions 100 and 300 Series 36 W Grill 13 22 15 16 58 3 cm 17 3 16 43 7 cm 10 5 8 26 9 cm 27 9 16 70 0 cm 8 20 3 cm 5 3 8 13 7 cm 27 13 16 70 6 cm 29 73 6 cm 3 mi...

Page 8: ...cm to combustable surface 6 15 2 cm VGBQ54203RE VGIQ54203RE 15 14 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 29 1 2 74 9 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to...

Page 9: ...n 300 Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Countertop typically requires 3 4 wide by 3 4 deep notch c...

Page 10: ...solid bottom to support the full weight of the unit Cutout Dimensions 500 Series 30 W Grill 19 10 1 8 25 7 cm 36 91 4 cm Access door opening 24 3 8 61 9 cm 35 1 4 89 5cm 3 7 6 cm min Electrical connec...

Page 11: ...Electrical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum dista...

Page 12: ...om inside floor of installation Vents located on sidewall Ventilation for Built In Installations An enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels...

Page 13: ...r Assembly Natural Fixed Piping Connection Check with your local gas utility company or with local codes for instructions on installing gas supply lines Be sure to check on type and size of run and ho...

Page 14: ...ed The LP Propane tank should be a standard 5 gal 20 lb gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP Pro...

Page 15: ...d detergent and one part water You will need a spray bottle brush or towel to apply the solution to the fittings Note For LP Propane units check with a full cylinder Check that all control knobs are i...

Page 16: ...ing to the directions following Note By replacing the knob it may be easier to light the burner A qualified installer should perform the following burner adjustments Each burner is tested and adjusted...

Page 17: ...ed skewer bushing should rest on the left side bracket Do not remove the plastic cover on the rotisserie motor switch due to safety consideration 32 WARNING ELECTRICAL SHOCK HAZARD This appliance is e...

Page 18: ...underneath the pullout drip tray on the left hand side Model number ____________________________________________________________________________________ Serial number ________________________________...

Reviews: