Viking Technology VRFEM2008GZIQSTH Manual Download Page 22

 

 

 

Manual 

3/28/2017 

PSFEM2xxxxZIxx 

Viking Technology 

Revision A 

 

Page 22 of 34 

www.vikingtechnology.com 

 

5.1  ATA Commands 

Table 5-1: Supported ATA Commands 

Description  

Op 
Code  

Description  

Op Code  

Check power mode 

E5h 

Security Disable Password 

F6h  

Data Set management  

06h  

Security Erase Prepare  

F3h  

DCO  

B1h 

Security Erase Unit  

F4h  

Download Microcode PIO  

92h  

Security Freeze Lock  

F5h  

Download Microcode DMA  

93h  

Security Set Password  

F1h  

Execute drive diagnostic  

90h  

Security Unlock  

F2h  

Flush cache  

E7h  

Seek  

70h  

Flush cache Ext  

EAh  

Set features  

EFh  

Identify device  

ECh  

Set Max Address  

F9h  

Idle  

E3h  

Set Max Address Ext  

37h  

Idle immediate  

E1h  

Set multiple mode  

C6h  

Initialize drive parameters  

91h  

Sleep  

E6h  

Read buffer  

E4h  

Smart  

B0h  

Read DMA (w/o retry)  

C9h  

Standby  

E2h  

Read DMA (w/retry)  

C8h  

Standby immediate  

E0h  

Read DMA Ext  

25h  

Write buffer  

E8h  

Read FPDMA QUEUED  

60h  

Write DMA (w/o retry)  

CBh  

Read Log Ext  

2Fh  

Write DMA (w/retry)  

CAh  

Read multiple  

C4h  

Write DMA Ext  

35h  

Read multiple Ext  

29h  

Write DMA FUA Ext  

3Dh  

Read native max address  

F8h  

Write FPDMA QUEUED  

61h  

Read native max Ext  

27h  

Write Log Ext  

3Fh  

Read sector(s) (w/o retry)  

21h  

Write multiple  

C5h  

Read sector(s) (w/retry)  

20h  

Write multiple Ext  

39h  

Read sector(s) Ext  

24h  

Write multiple FUA Ext  

CEh  

Read Verify Ext  

42h  

Write sector(s) (w/o retry)  

31h  

Read verify sector(s) (w/o retry)  

41h  

Write sector(s) (w/retry)  

30h  

Read verify sector(s) (w/retry)  

40h  

Write sector(s) Ext  

34h  

Recalibrate  

10h  

Write uncorrectable  

45h  

 
 
 

Summary of Contents for VRFEM2008GZIQSTH

Page 1: ...Page 1 of 34 www vikingtechnology com SATA 6Gb s Industrial mSATA Manual mSATA mini SATA MO 300 is a non volatile solid state storage device delivering Serial ATA performance reliability and ruggednes...

Page 2: ...FEM2xxxxZIxx Viking Technology Revision A Page 2 of 34 www vikingtechnology com Revision History Date Revision Description Checked By 3 28 17 Initial Release based on PSFEM2xxxxZxxx_B Add VRFEM2016GZI...

Page 3: ...term or condition of any kind either expressed or implied including but not limited to expressed and implied warranties of merchantability fitness for a particular purpose and non infringement While t...

Page 4: ...terface Temp User GB Client Ent NAND VRFEM2008GZIQSTH MO 300 40to 85 c 8 Client TSB 24nm H die SLC VRFEM2016GZIRSTH MO 300 40to 85 c 16 Client TSB 24nm H die SLC Notes 1 Higher capacity points may be...

Page 5: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 5 of 34 www vikingtechnology com Product Picture s...

Page 6: ...ins sophisticated provisions to protect firmware and data from corruption due to unexpected power loss However an Industrial SSD by industry definition does not contain on board capacitance Should pow...

Page 7: ...TE Command 15 2 4 Electrical Characteristics 15 2 4 1 Absolute Maximum Ratings 15 2 4 2 Supply Voltage 16 2 4 3 Power Consumption 16 2 5 Environmental Conditions 16 2 5 1 Temperature and Altitude 16 2...

Page 8: ...on Overlay Command Set 23 5 1 4 General Purpose Log Command Set 23 5 1 5 Host Protected Area Command Set 24 5 1 6 Power Management Command Set 24 5 1 7 Security Mode Feature Set 24 5 1 8 Identify Devi...

Page 9: ...bration Specifications_______________________________________ 17 Table 2 9 Reliability Specifications _______________________________________________ 17 Table 4 1 Mini PCIe Connector Pin Signal Defini...

Page 10: ...environments such as shock vibration humidity altitude ESD and extreme temperatures 1 1 Features The SSD delivers the following features Offers seamless SATA Revision 3 0 interface support for SATA u...

Page 11: ...PSFEM2xxxxZIxx Viking Technology Revision A Page 11 of 34 www vikingtechnology com 1 2 Block Diagram Figure 1 1 High Level Block Diagram Notes 1 Support for up to 2 channels and 2 CE in the NAND Flas...

Page 12: ...n revision 3 0 that supports SATA up to 6Gb s The SATA interface connects the host computer to the SSD subsystem The SATA interface runs at a maximum speed of 6 Gbps Giga bits per second If the host c...

Page 13: ...acity Flash Structure Performance1 CrystalDiskMark ATTO Read Write Read Write MB s MB s MB s MB s 14 16GB 16GBx1 BGA TSB H die SLC TBD TBD TBD TBD 30 32GB 32GBx1 BGA TSB H die SLC TBD TBD TBD TBD 60 6...

Page 14: ...TBD 512GB 15nm TBD TBD Notes 1 Performance measured using Iometer 08 with queue depth set to 32 2 Write Cache enabled with DDR cache 3 Random IOPS cover the entire range of legal logical block address...

Page 15: ...d Power Loss records the number of non graceful power cycle events Table 2 3 STANDBY IMMEDIATE Timing Power Cycle Endurance Min Max Unit STANDBY IMMEDIATE to WE completed 72 9 ms Notes From Standby Im...

Page 16: ...ie SLC TBD TBD TBD 60 64GB 32GBx2 BGA TSB H die SLC TBD TBD TBD 120 128GB 64GBx2 BGA TSB H die SLC TBD TBD TBD 240 256GB 128GBx2 BGA TSB H die SLC TBD TBD TBD 480 512GB 256GBx2 BGA TSB H die SLC TBD T...

Page 17: ...ystem EMI FCC compliance 2 6 Reliability Table 2 9 Reliability Specifications Parameter Description MTBF Over 2 000 000 hours ECC 72 bit per 1KByte Read Endurance Unlimited Write Endurance SLC TBW 16G...

Page 18: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 18 of 34 www vikingtechnology com Figure 3 1 Dimensions...

Page 19: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 19 of 34 www vikingtechnology com Notes All dimensions are in millimeters...

Page 20: ...Path P5 Reserved No Connect P6 Reserved No Connect P7 Reserved No Connect P8 Reserved No Connect P9 GND Return Current Path P10 Reserved No Connect P11 Reserved No Connect P12 Reserved No Connect P13...

Page 21: ...Connect Vendor Specific Manufacturing Pin 2 P46 Reserved No Connect P47 Optional No Connect Vendor Specific Manufacturing Pin 2 P48 Reserved No Connect Reserved P49 DAS Device Activity Signal P50 GND...

Page 22: ...diate E1h Set multiple mode C6h Initialize drive parameters 91h Sleep E6h Read buffer E4h Smart B0h Read DMA w o retry C9h Standby E2h Read DMA w retry C8h Standby immediate E0h Read DMA Ext 25h Write...

Page 23: ...nsisting of Download Microcode Executive Device Diagnostics Flush Cache Identify Device NOP optional Read Buffer optional Read DMA Read Multiple Read Sector s Read Verify Sector s Seek Set Features Se...

Page 24: ...tional Set Max Set Password optional Set Max Unlock optional 5 1 6 Power Management Command Set SSD supports the Power Management command set consisting of Check Power Mode Idle Idle Immediate Sleep S...

Page 25: ...20 ASCII characters 20 21 X 0000h Retired 22 X 0000h Obsolete 23 26 F Varies Firmware revision 8 ASCII characters 27 46 F Varies Model number xxxxxxxx 47 F 8010h 7 0 Maximum number of sectors transfer...

Page 26: ...set feature supported extension 85 V 3469h Command set feature enabled 86 V BC01h Command set feature enabled 87 V 6063h Command set feature default 88 V 003Fh Ultra DMA Modes 89 F 001Eh Time require...

Page 27: ...FA 168 F 3h 2 5 inch 4h 1 8 inch 5h 1 8 inch Device Nominal Form Factor 169 F 0001h DATA SET MANAGEMENT command is supported 170 173 F 0h Additional Product Identifier 174 175 0h Reserve 176 205 V 0h...

Page 28: ...on that may be used to analyze drive health SATA drives provide Self Monitoring Analysis and Reporting Technology SMART features that include monitoring and storing critical performance and calibratio...

Page 29: ...mmand Set Value hex Command 00 CF Reserved D0 S M A R T read attributes D1 S M A R T read threshold D2 S M A R T enable disable attribute autosave D3 S M A R T save attribute values D4 S M A R T execu...

Page 30: ...l Count B6h Erase Failure Block Count BBh Reported Uncorrectable Errors ECC fail count 4bytes 01h only 1 bytes C0h Unexpected Power Loss Count C2h N A C7h Number of accumulated CRC Error read write da...

Page 31: ...0 0 0 00h B6h 32h 00h 00h 00h Total erase bad blocks count 0 0 0 00h BBh 03h 00h 00h 00h Total ECC error count 0 0 0 00h C0h 12h 00h 64h 64h number of accidental power loss count 0 0 0 00h C2h N A N...

Page 32: ...causes the SSD to initiate the collection of S M A R T data in an off line mode and then preserves this data across power and reset events Supported subcommands include those shown in the table below...

Page 33: ...specification with regard to supported commands SSD s support the following features that are unique to the SATA specification 5 2 1 Native Command Queuing NCQ SSD s support the Native Command Queuin...

Page 34: ...Hard Disk Drive Hot Plug A term used to describe the removal or insertion of a SATA storage drive when the system is powered on IOPS Input output operations per second LBA Logical Block Address MB Meg...

Reviews: