1. Run 10" round steel ductwork, from exterior blower to the
installation location. For best performance, use the
straightest possible duct run and the fewest number of
elbows. Tape all joints.
2. Run 120 VAC electrical power cable from service panel
and from remote blower to installation location.
3. Remove wiring box cover. Remove knockouts from the
wiring box. Feed 6" of power cable through openings and
attach cables to wiring box with appropriate connectors.
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
4. Wire black to black, white to white, and green or bare wire
beneath green ground screw. Replace wiring box cover.
5. Attach rough-in plate to the studs at the inside top of hood
with (4) #10-24 nuts provided.
6. Connect ductwork to rough-in plate and tape joint.
7. Turn on power and check blower operation.
INSTALL THE ROUGH-IN PLATE
USE AND CARE
Disconnect electrical power supply and lock out service
panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully vacuum blower and inside of
housing. Be careful not to bend or otherwise damage
blower wheel.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disas-
semble motor.