5
Regulator Conversion
Flip Cap
Hex Nut Cap
Before proceeding with conversion, turn off gas supply and disconnect power to unit.
•
Sealed Surface Burner Models
Identify regulator type from rear of range/rangetop located underneath main top assembly.
•
Open Surface Burner Models
Identify regulator type from front of unit by removing grates, burner bowls and grate
support from far left side of range/rangetop.
•
Flip Cap
Press downward on regulator cap and turn counterclockwise to remove.
NOTE:
Regulator
cap is marked “Nat” on one side and “LP” on opposite side. Reverse regulator cap and
reinstall with LP side facing upward for LP operation.
•
Hex Nut Cap
Remove brass hex nut from top of regulator.
Unsnap plastic plunger from brass hex nut.
Reverse plunger and reinstall onto brass hex nut by pressing firmly.
NOTE:
Plunger is marked “Nat” and “LP”. Converted fuel type will be shown on the lower
portion of plunger.
Reinstall hex nut onto regulator in configuration desired.
T
N
E
V
RV48CL
1/2 PSIG
NAT-5
LPG-10
P
R
NAT
LP
CAUTION
NAT
LP
Natural
LP
Apply sideways
finger pressure
to remove pin
from cap