background image

6

INSTALLING THE OPTIONAL DUCT COVER 

1.  Measure from top of the canopy to ceiling and subtract 1/8” (0.3 cm) for clearance.
2.  Place the duct cover top inside the duct cover base and lower until desired height is found.  (To eliminate

scratches, make a mark on the duct cover top for the desired lowering point by subtracting 18” (45.7 cm) from the
total height needed.)

3.  Use the retaining nuts and bolts to fasten in place.
4.  Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.
5.  Note:  For installations with ceilings above 9’ (22.9 cm), use optional duct extensions.  See product literature for

details

Item 1

C

12” 
(30.5 cm)

Duct

Cover Top

Duct Cover

Base

Item 2

A

Min

B

Max

Item 4

Item 3

Canopy Top

Model

“A” Min.

“B” Max

“C”

DCH3042

18” (45.7 cm)

30” (76.2 cm)

16” (40.6 cm)

DCH3642

18” (45.7 cm)

30” (76.2 cm)

16” (40.6 cm)

Summary of Contents for DCH3042

Page 1: ...Built In Interior Power 12 H Chimney Hoods Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA Viking Installation Guide...

Page 2: ...void the hood warranty WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Installation work and electrical wiring must be done by qualified person s in a...

Page 3: ...staller or local codes for makeup air requirements if any S Sp pe ec ci if fi ic ca at ti io on ns s 3 30 0 W W M Mo od de el l 3 36 6 W W M Mo od de el l Exhaust Capacity 460 CFM 460 CFM Blower Motor...

Page 4: ...rom roof cap or wall cap to the installation location For best performance use the straightest possible duct run and the fewest number of elbows Tape all joints 2 Run 120 VAC electrical power cable fr...

Page 5: ...2 screws and 10 24 lock nuts provided 3 Attach the charcoal filter channel to the filter as shown 4 Slide the charcoal filter in place and install in hood A Af ft te er r i in ns st ta al ll li in ng...

Page 6: ...ng 18 45 7 cm from the total height needed 3 Use the retaining nuts and bolts to fasten in place 4 Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided 5 N...

Page 7: ...2 27 7 9 9 c cm m 1 12 2 3 30 0 5 5 c cm m 2 24 4 6 61 1 0 0 c cm m 1 16 6 4 40 0 6 6 c cm m A A B B 9 9 3 3 4 4 2 24 4 8 8 c cm m 1 12 20 0V V 7 7 D Di ia a D Du uc ct t A A B B 3 30 0 W W 2 29 9 7 7...

Page 8: ...4 1 15 5 1 16 6 7 75 5 9 9 c cm m 3 37 7 9 9 c cm m 3 36 6 W W 3 35 5 7 7 8 8 1 17 7 1 15 5 1 16 6 9 91 1 1 1 c cm m 4 45 5 6 6 c cm m 1 12 2 3 30 0 5 5 c cm m 1 12 2 3 30 0 5 5 c cm m 2 24 4 6 61 1...

Page 9: ...WIRING DIAGRAM BUILT IN 12 H CHIMNEY HOODS 9...

Page 10: ...10...

Page 11: ...11...

Page 12: ...81B PS1006VR Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange...

Reviews: