![Viking Electronics K-1775-BN-IP Product Manual Download Page 10](http://html.mh-extra.com/html/viking-electronics/k-1775-bn-ip/k-1775-bn-ip_product-manual_1026060010.webp)
10
B. Configuring the K-1700-IP Network Settings
Step 1.
Open the “Viking K-1700-IP Phone Programming” software on a windows PC that is connected to the same LAN as the
K-1775-IP
phone to be programmed.
Step 2.
The window in the upper left corner of the menu will show you each
K-1775-IP
phone that is connected to that LAN. Select the unit
with the same MAC address shown on the label located on the top of the Ethernet connector on the
K-1775-IP
phone.
Step 3.
Click the “Connect” button. If a pop up window appears, enter the unit’s security code (factory set to
845464
) then click “OK”.
Step 4.
The program will then read and display the
K-1775-IP
phone’s IP and programming settings.
Step 5.
After adjusting the IP and phones settings, click the “Write” button under each column of settings to send the programming commands
to the connected unit.
D. Manually Resetting All Network Parameters to Factory Default
Step 1.
Power down the
K-1775-IP
phone by disconnecting the RJ45 plug.
Step 2.
Press and hold the CALL button, then reconnect the RJ45.
Step 3.
Continue to hold the button until you hear 2 beeps, (approximately 6 seconds). Continue to hold the button until you hear 4 more
beeps, approximately 6 seconds later, then release the button. The “Call” LED will remain off for the first 3 seconds, flash slowly for 3
seconds (2 beeps), fast flash for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4.
The unit should continue to output double beeps and slowly flash the LED indicating all Network Parameters are now reset to factory
default.
Step 5.
You will be required to re-enter your initial network settings, see section
B
above.
Step 1.
Power down the phone by disconnecting the RJ45 plug.
Step 2.
Press and hold the CALL button, then reconnect the RJ45.
Step 3.
Continue to hold the button until you hear 2 beeps, (approximately 6 seconds). Then release the button. The “Call Connected” LED will
remain off for the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2 beeps) indicating when to release button.
Step 4.
The security code is now reset to
845464
(factory default).
Step 5.
You can now enter programming by following the steps in section
B
above.
C. Manually Resetting the Security Code to Factory Default