Application Drawing
Vi22001 Single Port 90W PoE++ Midspan Installation Manual
IP Camera-end Installation
The Smart Choice for Transmission Solutions
www.vigitron.com
Important Safety Warning
- Connect the UTP Cables (cat5/6) from the IP camera or other PoE
powered device to the Data + PoE RJ45 connector of Vi22001. The cable
must be a cat5/6 with a maximum length of 100m (328 feet).
Ethernet Switch/NVR-end Installation
- Connect the UTP Cable (cat5/6) from the Ethernet switch to the Data RJ45
connector of Vi22001. The total length of UTP cable from network switch to
the powered PoE device should not exceed 100m (328 feet).
- Plug the AC power cord provided with the unit to the mains.
- Read these instructions. Keep these instructions. Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should
conform to all local codes.
- DO NOT bundle UTP signal wires in the same conduit as high-voltage wiring.
- To reduce the risk of fire or electrical shock, do not expose these products
to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron
equipment.
- DO NOT install the unit in a place where the operating ambient tempera-
ture exceeds 60° C.
- Make sure that the power source voltage is in the recommended range.
- Do not install near any heat sources such as radiators, heat registers,
stoves or other apparatus that produce heat.
- Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long
periods of time.
- Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as a power
supply cord or plug is damaged, liquid has been spilled, or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
- The mains plug is used as the disconnect device and shall remain readily
operable.
WARNING! - To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture. This apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such as vases shall
be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must
be connected to a mains socket outlet through an AC to DC Power supply
when using DC input.
WARNING! - The mains plug is used as the disconnect device and
shall remain readily operable.
The MaxiiPower Model
Vi22001 is a unique Single port PoE Midspan
designed for the most demanding power applications of 10/100/1000
Base-T networks. With the ability to provide up to 90W PoE power, it is the
most cost effective method for powering PTZ domes cameras with heaters
and blowers. The Midspan is compliant IEEE 802.3af, IEEE 802.3at ,
Proposed IEEE 802.3bt and UPoEstandards and up to 90W PoE applica-
tion.
The Vi22001 can virtually meet requirements of any high power PoE
application. Its unique internal control system enables it to handle both
single PD and dual PD PoE devices.
The Midspan is equipped with LEDs to provide power status. No IP setting
or configurations are required and it can completely transparent to the
Ethernet network and higher layer protocols.
The Vi22001 is smaller, lighter and easier to fit in environmental enclosures
UMVi22001_0519
PoE Midspans
TM
Network Switch
60W IP Camera
Vi2301A
Vi22001
Vi2301A
110/220VAC
Vi22001
110/220VAC
Vi22001
110/220VAC
60W IP Camera
60W IR
The Vi22001 can provide up to 90W PoE power to high power IP cameras
or IR illuminators.
328 ft. (100m)
Data +
90W PoE
Extended Distance
Data +
90W PoE
328 ft. (100m)
Data +
90W PoE
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.