background image

 

Application Drawings 

Vi3002 Hardened Ethernet and 60W PoE Repeater Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

Important Safety Warning

PoE Switch-end Installation

- Read and keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should conform to all local 

  codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.

- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture,

  dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.

- DO NOT install the unit in a place where the operating ambient temperature exceeds 70°C or  

   is below - 10°C.

- Make sure that the external power supply output voltage is in the recommended range. 

- Do not install near any heat sources such as radiators, heat registers, stoves or other 

  apparatus that produce heat.

- Protect the power cord from being walked on or pinched particularly at power source, 

  convenience receptacles, and the point where they exit from the apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long periods of time.

- Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

  has been damaged in any way, such as when a power supply cord or plug is damaged, liquid

  has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed 

  to rain or moisture, does not operate normally, or has been dropped.

- The main plug is used as the disconnect device and shall remain readily operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - The Ethernet cable is used as the disconnect device and 

shall remain readily operable. 

Vi3002_UM

a) A single Vi3002:

-  Connect one of the RJ45 connectors of the Vi3002 to a standard 

   Cat5/6 cable of maximum 328 feet (100m). Connect the other end of the 

   cable to the Ethernet port of the a PoE Switch or PoE Midspan. 

-  Connect of the other RJ45 connector of the Vi3002 to a standard 

   Cat5/6 cable of maximum 328 feet (100m).  

-  Connect the other end of the Cat5/6 cable to the Ethernet port of the the IP 

   camera or any other PoE device.

Vigitron’s MaxiiNet™ Vi3002 is an Ethernet and 60W PoE repeater that 

provides a cost effective method for extending distances beyond the 

Ethernet limit of 328 feet (100m) for IT or CCTV installations. Each unit can 

extend Ethernet and PoE for 328 feet (100m). Up to 8 units can be 

combined to achieve a distance up to 3,000 feet (909m) for IP video and 

PoE transmission. The Vi3002 is a high performance device that meets the 

demands for the highest PoE powered PTZ domes and LED lighting 

eliminating the need for local power.

The Vi3002 is designed for the operating temperature range of -20°C to 

+75°C. It uses PoE only and its Pass-Through-PoE (PTP

TM

) eliminates the 

need for local power supplies.

It is compact in size and easy to install. The Vi3002 is very cost effective 

and is a perfect solution for any extended IP transmission applications.

Max

ii

 

Net

TM

Extending Ethernet and 60W PoE from a PoE Switch 

Cat 5/6

8xVi3002 for total of 2,950 ft. (900m)

Network Switch

PoE Midspan

Vi3002

90W PoE Switch

Data +

 60W PoE

328 ft. (100m)

Data + 

60W PoE

328 ft. (100m)

60W PTZ Dome

Vi3002

(#8)

Vi3002

(#1)

Network PoE Switch

Data + 

60W PoE

328 ft. (100m)

60W PTZ Dome

Vi3002

Data +

 60W PoE

328 ft. (100m)

Data + 

60W PoE

328 ft. (100m)

60W PTZ Dome

Data +

 PoE

328 ft. (100m)

Data +

 PoE

328 ft. (100m)

Data +

 PoE

328 ft. (100m)

Extending Ethernet and 60W PoE from a Switch & PoE Midspan

Extending Ethernet and 60W PoE using multiple Vi3002s

A single Vi3002 extendends Ethernet and PoE from a PoE switch for total Distance of 656 ft. 

Up to 8 x Vi3002 can be used in series to extend Ethernet and PoE for up to 2,950 ft. (900m).

A single Vi3002 extendends Ethernet and PoE from a network switch and a PoE Midspan for 

total Distance of 656 ft. (200m).

The Vi3002 can be used to connect multiple PoE cameras at extended distances.

Connecting Multiple PoE Cameras at Extended Distances

Data+

60W PoE

328 ft. (100m)

Data+

PoE

328 ft. (100m)

Data+

PoE

328 ft. (100m)

Data+

PoE

328 ft. (100m)

Data+

PoE

328 ft. (100m)

Data+

PoE

328 ft. (100m)

PoE Switch

Vi3005

PoE Cameras

Vi3002

Reviews: