5. Get-Function Listing
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet
format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the
“Value” byte is always = 00.
Get-Function description:
Length
Total Byte of Message excluding “CR”
TV ID
Identification for each of TV. The TV ID doesn’t be supported by HDTV power
status on standby.
Command Type
Identify command type,
“g” (0x67h) : Get Command
Command
Function command code: One byte ASCII code
Value[1~3]
Three bytes ASCII that defines the value
CR
0x0D
Get-Function format:
Send (Command Type= “g”)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
(Command Type= “g”, Only for HDTV power status on standby)
Name
Length
Command
Type
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2
3
4
5
6
7
Reply: (Command Type= “r” or “-”)
If the Command is valid, Command Type = “r”
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
If the Command is valid, Command Type = “r”, Only for HDTV power status on standby.
Name
Length
Command
Type
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2
3
4
5
6
7
If the Command is Not valid, Command Type= “-”
Name
Length
ID
Command
Type
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
Summary of Contents for VT3205LED