6.2. NO POWER
Chcek P100
5V,12V
Check 3.3V is on C113?
1.9V is on I102 Pin2?
Yes
Yes
Yes
Yes
Replace I106
& I107
START
Check X100 is OK?
Replace I101
Replace I102
No
No
No
Replace IR Board
Replace x100
No
No
Check Wire Connection on
power board is OK?
Replace Power Board
Connect the wire
Yes
No
Yes
Check IR Board
ViewSonic Corporation
Confidential - Do Not Copy
N3250w-1L
52
Summary of Contents for N3250w-1L
Page 14: ...Remote Control ViewSonic Corporation Confidential Do Not Copy N3250w 1L 11 ...
Page 58: ...7 Block Diagram ViewSonic Corporation Confidential Do Not Copy N3250w 1L 55 ...
Page 77: ...8 19 Power board ViewSonic Corporation Confidential Do Not Copy N3250w 1L 74 ...
Page 80: ...9 2 MAIN PCB BOTTOM VIEW ViewSonic Corporation Confidential Do Not Copy N3250w 1L 77 ...
Page 81: ...9 3 CON PCB TOP VIEW ViewSonic Corporation Confidential Do Not Copy N3250w 1L 78 ...
Page 82: ...9 4 CON PCB BOTTOM VIEW ViewSonic Corporation Confidential Do Not Copy N3250w 1L 79 ...
Page 83: ...9 5 IR PCB TOP VIEW ViewSonic Corporation Confidential Do Not Copy N3250w 1L 80 ...
Page 84: ...9 6 IR PCB BOTTOM VIEW ViewSonic Corporation Confidential Do Not Copy N3250w 1L 81 ...
Page 86: ...ViewSonic Corporation Confidential Do Not Copy N3250w 1L 83 ...