49
3. Time log data example
Assumed the power-on/off record of display#01 as below
2014-8/31 08:00 On
2014-8/31 22:00 Off
2014-9/1 10:30 On
2014-9/1 11:00 To send “GET-Time log” command
Send: 0x 38 30 31 67 31 30 30 30 0D
Reply:
#1
0x 38 30 31 72 31 31 28 51 0D (On 8/31)
#2
0x 38 30 31 72 31 31 28 20 0D (On 08:00)
#3
0x 38 30 31 72 31 30 28 51 0D (Off 8/31)
#4
0x 38 30 31 72 31 30 42 20 0D (Off 22:00)
#5
0x 38 30 31 72 31 31 29 21 0D (On 9/1)
#6
0x 38 30 31 72 31 31 20 50 0D (On 10:30)
9.3.3 Remote Control Pass-through mode
When PC sets the TV/DS to Remote Control Pass through mode, the TV/DS shall
send a 7-byte packet (followed by “CR”) in response to RCU button activation. Note,
that in this mode the RCU shall have no effect on the TV/DS function. For example:
“” will not change the volume in the LCD but only sends “” code to
PC over the RS232 port.
IR Pass Through-Function format
Reply: (Command Type=”p”)
Name Length
ID
Command
Type
RCU Code1
(MSB)
RCU Code2
(LSB)
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
6
7
Example1: Remote Control pass-through when “VOL+” key is pressed for TV-05
Send (Hex Format)
Name Length
ID
Command
Type
RCU Code1
(MSB)
RCU Code2
(LSB)
CR
Hex
0x36
0x30
0x35
0x70
0x31
0x30
0x0D
Key
Code (HEX)
1
01
2
02
3
03
4
04
Summary of Contents for CDE5501