14.
Hardware Parameter
Gimble Working
voltage
Searchlight Working
voltage
Output voltage
Idle current
3000mA@17V
3S~6S
17V
5V (connect with PWM)
S.Bus control mode: default S.Bus signal channel 7-13 to control
gimbal camera functions (the function of channel is consistent with
corresponding channel in PWM function description)
User can set the channels by setting serial command
according to the actual requirement. The S.Bus channel
position can be arranged in any sequence within
channel 1-15 to connect with the flight controller or
remote control.
4. Specification
Channel 7: Yaw Control
Channel 8: Pitch Control
Channel 9: Mode Control
Channel 10: Zoom Control
Channel 11: Focus Control
Channel 12: Pic/Rec Control
Channel 13: Multi Backup