14
5472 726 - 02
Vitotron 100 Electric Space Heating Hot Water Heater Installation/Service
Winter Mode
(Heating Mode)
(continued)
Instructions for the User
SUPPLY WATER TEMPERATURE VIEW
INDICATOR
DETAILS
°F
The LED in the first location on the display indicates automatic setting, according to the
heating curve and offset (see parameters 4 and 5 in advanced settings). This is active
only when the outdoor sensor is wired to Text terminals on control panel.
Manual setting (see parameter 4 in advanced settings), outlet temperature can be set
manually in range 85 - 140°F.
Use buttons
and
to change the parameter.
INLET TEMPERATURE VIEW
°F
Inlet temperature
OUTLET TEMPERATURE VIEW
°F
Outlet temperature
FLOW VIEW
gpm
Flow rate [gallons/min.]
PRESSURE VIEW
psi
Pressure level [pounds/square inch]
ENERGY CONSUMPTION VIEW
X100
BTU/h
Current energy consumption [BTU/h]
OUTDOOR TEMPERATURE VIEW
°F
Outdoor temperature. In case of lack of outdoor temperature sensor, preview is not available