15
Information on language setting
If a particular language is not available,
set the operating language to English.
Available languages:
■ German
■ Danish
■ English
■ French
■ Italian
■ Dutch
■ Polish
■ Spanish
■ Czech
■ Turkish
■ Hungarian
1.
Turn on the ON/OFF switch on the
boiler control unit.
The following information appears
in sequence:
■ Segment test (all symbols are
displayed)
■ Equipment code and software
version (10.64 or 10.65)
■
"OPEN THERM"
If
"0 - 10 V"
appears here, select
"OPEN THERM"
. See
page 18.
■ If
"OT CONTROL"
flashes, enter
the following settings:
2.
Change settings with
+/-
or the
rotary selector, and confirm with
OK
.
■ Select the operating mode:
– For room temperature-depend-
ent mode:
"ROOM-CON-
TROL"
– For weather-compensated
mode:
"OT CONTROL"
An outside temperature sensor
must be connected to the boiler
control unit.
■
"LANGUAGE"
■
"YEAR"
■
"MONTH"
■
"DAY"
■
"HOUR"
■
"MINUTE"
Commissioning is complete when
the current room temperature
appears.
For further settings, see page 16.
Note
The automatic summer/wintertime
changeover can be set under
"SU/WI RULE"
.
Operating instructions
Setting the mixer extension kit parameters
Calling up and changing parameters
Display and adjustment are made on
the room temperature controller.
0
1.
Press
MODE
.
0
2.
Use / to select
"SETTINGS"
.
0
3. OK
to confirm
Commissioning and adjustment
Starting up the room temperature controller
5837759