![Viessmann VITOSOLIC 200 Operating Instructions For The System User Download Page 7](http://html1.mh-extra.com/html/viessmann/vitosolic-200/vitosolic-200_operating-instructions-for-the-system-user_1017713007.webp)
7
Press the following keys:
1.
for the
"Main menu"
.
2. OK
the first 3 actual values will be
displayed.
3.
/
for the following actual values,
subject to system equipment
level.
4.
until the
"Main menu"
appears.
"Actual values:"
Explanation
"Tcol"
Collector temperature in °C
"Tcol2"
Collector temperature in an additional collector array in °C
"Tcylb"
Actual cylinder temperature in °C
"Tcyl2b"
to
"Tcyl4b"
Actual cylinder temperature for additional consumers (e.g.
2nd DHW cylinder) in °C
"Tby"
Bypass temperature in °C
"T-HE"
Temperature in an external heat exchanger in °C
"Cyl. add."
Additional function for DHW heating
"Time"
"Date"
"Relay"
Condition of relays
"Sensors"
Temperature at the respective sensor in °C
Note
If the sensor inputs are not connected, the breaking value (in-
dicating a lead break) is displayed.
"Intens."
Radiation intensity in conjunction with a solar cell
Note
If the input is not connected, the breaking value (indicating a
lead break) is displayed.
A diagram in the
standard display
ena-
bles you to check the collector and actual
cylinder temperatures over the course of
the day. If your heating contractor has
enabled the heat meter, a diagram is
also displayed showing the heat amount
for the past 7 days.
Repeatedly press , this brings up the
following diagrams:
Scanning options
Calling up actual values
5608 437 GB