6
z
β
α
α
z Collector row clearance
α
Collector angle of inclination
β
Angle of the sun
Angle of inclination α
Clearance between collector rows z in mm
Type SV
Type SH
Flensburg
30°
7630
5715
45°
9600
4260
60°
10890
4830
Kassel
30°
6385
2845
45°
7840
3480
60°
8720
3870
Munich
30°
5595
2485
45°
6710
2980
60°
7350
3260
Installation information
■ Where possible, the collector array
should face due south.
■ Observe the maximum load and dis-
tance from the edge of the roof for the
on-site substructure to DIN 1055.
■ Installation on concrete slabs
A
(see
diagram on page 8):
Remove any gravel or similar from the
installation area, cover the surface
with protective building mats and posi-
tion the supports on them.
Determining collector row clearance z
(cont.)
5727 904 GB
Summary of Contents for Vitosol-F Type SH
Page 15: ...15 5727 904 GB ...